    1 W415-0580 / C / 04.07.08 $10.00 INSTALLATION AND OPERATION INSTRUCTIONS Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.on.ca CERTIFIED UNDER CANADIAN AND AMERICAN NA TIONAL STANDARDS: CSA 2.22, ANSI Z21.50 FOR VENTED GAS FIREPLACES. BGD90NT NATURAL GA ...

  • Napoleon Fireplaces BGD90NT - page 2

    2 W415-0580 / C / 04.07.08 PG2-5 INTRODUCTION Warning Warranty Fireplace Dimensions Installation Overview General Instructions General Information Care of Glass 6-10 VENTING V enting lengths and Air T erminal Locations Defi nitions Elbow V ent Length V alues Horizontal T ermination V ertical T ermination Minimum Air T erminal Locations 11-16 INST ...

  • Napoleon Fireplaces BGD90NT - page 3

    3 W415-0580 / C / 04.07.08 ALL SPECIFICA TIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON®® IS A REGISTERED TRADEMARK OF WOLF STEEL L TD. PA TENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.915. © WOLF STEEL L TD. NAPOLEON® products are manufactured under the strict Standard of the worl ...

  • Napoleon Fireplaces BGD90NT - page 4

    4 W415-0580 / C / 04.07.08 6" FIGURE 1 INST ALLA TION O VERVIEW See the section “MINIMUM MANTEL AND ENCLOSURE CLEARANCES” See the section “FRAMING” See the section “VENTING” and “IN- ST ALLA TION” Side Wa l l See the section “FRAMING” See the section “FRAMING” and “MINIMUM MANTEL AND ENCLOSURE CLEARANCES” for Drywal ...

  • Napoleon Fireplaces BGD90NT - page 5

    5 W415-0580 / C / 04.07.08 GENERAL INSTRUCTIONS GENERAL INFORMA TION This gas fireplace should be installed and serviced by a qualified installer to conform with local codes. Installation practic es vary from region to region and it is important to know the specifics that apply to your area, for example: in Massachusetts State: • The fireplace da ...

  • Napoleon Fireplaces BGD90NT - page 6

    6 W415-0580 / C / 04.07.08 * 16” MINIMUM 40 FEET MAXIMUM 3 FEET MINIMUM FIGURE 3b When using Wolf Steel Ltd.venting components, use only approved Wolf Steel Ltd. fl exible vent components with the following termina- tion kits: W ALL TERMINAL KIT GD622 , or 1/12 T O 7/12 PITCH ROOF TERMINAL KIT GD610 , 8/12 TO 12/12 ROOF TERMINAL KIT GD61 1 , FLA ...

  • Napoleon Fireplaces BGD90NT - page 7

    7 W415-0580 / C / 04.07.08 VERTICAL RISE IN FEET V T FIGURE 4 See graph to determine the required vertical rise V T for the required horizontal run H T . For vent confi gurations requiring more than one 90° elbow , the following formulas apply: F or mula 1: H T < V T F or mula 2: H T + V T < 40 feet Example 1: 90° 90° V 1 = 3 ft V 2 = 8 f ...

  • Napoleon Fireplaces BGD90NT - page 8

    8 W415-0580 / C / 04.07.08 H 2 H 1 V 1 90° See graph to determine the required vertical rise V T for the required horizontal run H T . V 1 = V T = 6 ft H 1 = 3 ft H 2 = 5 ft H R = H 1 + H 2 = 3 + 5 = 8 ft H O = .03(two 90° elbows - 90°) = .03(180° - 90°) = 2.7 ft H T = H R + H O = 8 + 2.7 = 10.7 ft H T + V T = 10.7 + 6 =16.7 Formula 1: H T < ...

  • Napoleon Fireplaces BGD90NT - page 9

    9 W415-0580 / C / 04.07.08 MAXIMUM VERTICAL RISE IN FEET V T HORIZONT AL VENT RUN PLUS OFFSET IN FEET H T The shaded area within the lines represents acceptable values for H T and V T . See graph to determine the required vertical rise V T for the required horizontal run H T . For vent confi gurations requiring more than two 90° elbow (top exit) ...

  • Napoleon Fireplaces BGD90NT - page 10

    10 W415-0580 / C / 04.07.08 MINIMUM AIR TERMINAL L OCA TION CLEARANCES . FIGURE 12 ...

  • Napoleon Fireplaces BGD90NT - page 11

    11 W415-0580 / C / 04.07.08 INST ALLA TION / FRAMING WALL AND CEILING PR O TECTION HORIZONT AL VENT SECTIONS: A minimum clearance of 2” all around the vent pipe on all horizontal runs to combustibles is required except for clearances in fi replace enclosures**. Use fi restop spacer assembly W010-1797 (supplied). VERTICAL VENT SECTIONS: A minimu ...

  • Napoleon Fireplaces BGD90NT - page 12

    12 W415-0580 / C / 04.07.08 USING FLEXIBLE VENT COMPONENTS ELBOW SP ACERS Do not allow the inside vent pipe to bunch up on horizontal or vertical runs and elbows. Keep it pulled tight. A 3/4” air gap be- tween the liner and the outer liner all around is required for safe op- eration. A spacer is required at the start, middle and end of each elbow ...

  • Napoleon Fireplaces BGD90NT - page 13

    13 W415-0580 / C / 04.07.08 FLUE COLLAR RESTRICTOR PLA TE FIGURE 23 FIGURE 24 W ARNING THE STANDOFFS HA VE BEEN SHIPPED FLAT . BEFORE FRAMING ENSURE THE STANDOFFS ARE BENT UP AND SCREWED INTO PLACE. A TTENTION A TENCIÓN LAS TRABAS PERMANECEN PLANAS DURANTE EL ENVÍO. ANTES DE LA INST ALACIÓN, VERIFIQUE QUE LAS TRABAS SE PLIEGUEN HACIA ARRIBA Y SE ...

  • Napoleon Fireplaces BGD90NT - page 14

    14 W415-0580 / C / 04.07.08 59 1 / 4 " 1" MIN 1" MIN 11 6 " 82" FIGURE 25 FIGURE 28 59 1 / 4 " 29 1/2" 29 1/2" 10" MIN 59 1 / 4 " FIGURE 26 FIGURE 27 ...

  • Napoleon Fireplaces BGD90NT - page 15

    15 W415-0580 / C / 04.07.08 73 1 / 4 " 60 3 / 4 " 5 1 / 2 " 23 3 / 4 " 5 1 / 2 " Use only non-combustible material such as cement board, ceramic tile, marble, etc. when finishing to the fireplace. DO NOT USE WOOD OR DR YW ALL. ! W ARNING FIGURE 29 MINIMUM CLEARANCE T O COMBUSTIBLES Maintain these minimum clearances to combu ...

  • Napoleon Fireplaces BGD90NT - page 16

    16 W415-0580 / C / 04.07.08 RECEIVER Receiver 12 Pin Connector 11 0 V O U T Receiver Hearth Mount OFF ON REMOTE TPTH TP TH FCM-COM FA N A UX O U T Red Black MOTOR Green White Fan Control Module (FCM) OUT Modulating 820 Night Lights ON OFF REMOTE Receiver Wall Mount BLOWER FIGURE 30 MINIMUM MANTEL AND ENCLOSURE CLEARANCES Combustible mantel clearanc ...

  • Napoleon Fireplaces BGD90NT - page 17

    17 W415-0580 / C / 04.07.08 Before the glass door can be removed, the control doors must be opened and the hearth strip and screen assembly must be removed. LOG SHIPPING BRA CKET DOOR REMO V AL HEARTH STRIP RET AINER C O N T R O L D O O R S LOG SHIPPING BRACKET FIGURE 33 H O O K S ROD FIGURE 34 SCREWS FIGURE 35 FINISHING Before installing the logs, ...

  • Napoleon Fireplaces BGD90NT - page 18

    18 W415-0580 / C / 04.07.08 Brick panels are shipped separate from unit due to the brittle material of the bricks, care must be taken not to bend or force them into place. When shipped, the brick panels range in varying shades of Sandstone. During initial use, the panels will darken temporarily . The appearance of the panels will permanently lighte ...

  • Napoleon Fireplaces BGD90NT - page 19

    19 W415-0580 / C / 04.07.08 6. Place the pin in log #7 in the hole in log #6. The log should sit in the notch on log #2 and the bottom should rest along the right side of the Andiron. 8 PHAZER™ logs and glowing embers, exclusive to Wolf Steel Ltd.Fireplaces, provide a unique and realistic glowing ef fect that is different in every installation. T ...

  • Napoleon Fireplaces BGD90NT - page 20

    20 W415-0580 / C / 04.07.08 Randomly place the charcoal embers along the front and sides of the Hearth Panels in a realistic manner . Fine dust found in the bottom of the bag should not be used. Sprinkle vermiculite around the charcoal embers. NOTE: Both charcoal embers and vermiculite are not to be placed on the burner . T ear the embers into piec ...

  • Napoleon Fireplaces BGD90NT - page 21

    21 W415-0580 / C / 04.07.08 RECEIVER SLOT SP ARK MODULE VA LV E WING NUT INNER ACCESS PA N E L 1. Remove access panel from inside the fi rebox. 2. Unplug the control module from the junction box 3. Pull up on the control module being held down with velcro and disconnect the plugs (fan, aux). Remove wiring harness from the front of the casing. 4. I ...

  • Napoleon Fireplaces BGD90NT - page 22

    22 W415-0580 / C / 04.07.08 FIGURE 49 HAND HELD REMO TE OPERA TIONS 1. Install 4 AA batteries into the receiver battery bay as indicated on the battery cover (+/-). 2. Place the 3 position slider switch in the “Remote” position. 3. Using the end of a paper clip, or other similar object, insert the end of the paper clip into the hole marked “P ...

  • Napoleon Fireplaces BGD90NT - page 23

    23 W415-0580 / C / 04.07.08 1. Press the Thermostat Key . The LCD display on the T ransmitter will show that the room is “ON” and the set temperature is now displayed. 2. T o adjust the set temperature, press the Up/Down Arrow Keys until the desired set tem- perature is displayed on the LCD screen of the T ransmitter. The Smart Thermostat funct ...

  • Napoleon Fireplaces BGD90NT - page 24

    24 W415-0580 / C / 04.07.08 LO W BA TTER Y / MANU AL BYP ASS The life span of the remote batteries depends on various factors: quality of the batteries, the number of ignitions, the number of changes to the room thermostat set point, etc. When the transmitter batteries are low , a Battery Icon will appear on the LCD display before all battery power ...

  • Napoleon Fireplaces BGD90NT - page 25

    25 W415-0580 / C / 04.07.08 A. This fi replace is equipped with a pilot which must be lit by hand while following these instructions exactly . B. Before operating smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor . C. Use only your hand to turn the gas control ...

  • Napoleon Fireplaces BGD90NT - page 26

    26 W415-0580 / C / 04.07.08 Purg e all gas lines with the glass door of the f ire place remo ved. Assur e that a contin uous gas flow is a t the burner befor e installing the door . TURN OFF THE G AS AND ELECTRICAL POWER BEFORE SERVICING THE FIREPL ACE. CAUTION: Label all wires prior to disconnection when servic- ing controls. Wiring errors can cau ...

  • Napoleon Fireplaces BGD90NT - page 27

    27 W415-0580 / C / 04.07.08 67* W573-0007 HI-TEMP SEALANT 68* GD501 HEA T GUARD 69 GA-566 HOT AIR DISTRIBUTION KIT 70 GA-72 HOT AIR EXHAUST KIT 71 GA-70 EXTENSION KIT , 5FT FLEX VENT 72* W010-0370 W ALL SUPPORT ASSEMBL Y 73* W175-0249 10” COUPLER 74* W175-0002 8” COUPLER 75* W175-0260 CONVERSION KIT - NG TO LP 75* W175-0261 CONVERSION KIT - LP ...

  • Napoleon Fireplaces BGD90NT - page 28

    28 W415-0580 / C / 04.07.08 6 4** 8 7 5 41 23 28 29 30 31 35 27 26 34 64 33 66 32 11 65 21 2 15 16 12 3 14 19 17 71 55 58 22 79 63 69 70 13 ...

  • Napoleon Fireplaces BGD90NT - page 29

    29 W415-0580 / C / 04.07.08 White / grey film forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- faces. - clean the glass with a gas fi replace glass cleaner . DO NOT CLEAN GLASS WHEN HOT . If deposits are not cleaned off regularly , the glass may become per- manently marked. Carbon is being de- posited on glass, ...

  • Napoleon Fireplaces BGD90NT - page 30

    30 W415-0580 / C / 04.07.08 Main burner goes out; pilot goes out. Main burner goes out; pilot stays on. Pilot fl ame is not large enough or not engulfi ng the thermo- pile - turn up pilot fl ame. - replace pilot assembly . Thermopile shorting - clean thermopile connection to the valve. Reconnect. - test and replace thermopile if required. T empe ...

  • Napoleon Fireplaces BGD90NT - page 31

    31 W415-0580 / C / 04.07.08 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS ...

  • Napoleon Fireplaces BGD90NT - page 32

    32 W415-0580 / C / 04.07.08 NO TES ...

メーカー Napoleon Fireplaces カテゴリー Indoor Fireplace

Napoleon Fireplaces BGD90NTのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- BGD90NTの取扱説明書
- Napoleon Fireplacesの製品カード
- パンフレット
- またはNapoleon Fireplaces BGD90NTの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Napoleon Fireplaces BGD90NTの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Napoleon Fireplaces BGD90NTの取り付け説明書、サービスマニュアル、簡易説明書、またはNapoleon Fireplaces BGD90NTのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Napoleon Fireplaces BGD90NTの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Napoleon Fireplaces BGD90NTデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがNapoleon Fireplaces BGD90NTを使用するのを助ける技術的文書のことです。説明書は通常、全てのNapoleon Fireplaces BGD90NTユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Napoleon Fireplacesの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Napoleon Fireplaces BGD90NTの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははNapoleon Fireplaces BGD90NTの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Napoleon Fireplaces BGD90NTに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Napoleon Fireplaces BGD90NTデバイスの基本機能を使うにあたってのヒント。 Napoleon Fireplaces BGD90NTのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Napoleon Fireplaces BGD90NTに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるNapoleon Fireplaces BGD90NTのメーカー/サービスへの連絡先に関する情報。

Napoleon Fireplaces BGD90NTについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもNapoleon Fireplaces BGD90NTの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがNapoleon Fireplaces BGD90NTで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)