Sears 390.252158の取扱説明書

16ページ 0.8 mb
ダウンロード

ページに移動 of 16

Summary
  • Sears 390.252158 - page 1

    SEARS OWNER'S MANUAL MODEL NO. 390.252158 CAUTION: Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product. Save This Manual For Future Reference. CRAFTSMAN ° PROFESSIONAL 112 HP SHALLOW WELL WATER SYSTEM • Safety Instructions • Installation • Electrical • Maintenance • Repair Parts Sears, Roebuc ...

  • Sears 390.252158 - page 2

    CONTENTS INTRODUCTION/WARRANTY .......................................... 2 PUMP PERFORMANCE ....................................................... 3 MAJOR COMPONENTS ...................................................... 3 INSTALLATION ................................................................ 4-5 ELECTRICAL ................................ ...

  • Sears 390.252158 - page 3

    SAFETY INSTRUCTIONS (Continued) 6. Disconnect electrical power source before installing or working on pump. 7. Ground pump with a ground wire run from grounding lug on motor to a grounded lead in the service panel. 8. Line voltage and frequency of electrical power supply must agree with motor nameplate. 9. Use of fuses or wire smaller than size rec ...

  • Sears 390.252158 - page 4

    INSTALLATION INSTALLATION Piping in the Well The Shallow Well Water System can be installed on a dug well, drilled well or with a driven point. In a dug or cased well, a foot valve and strainer should be installed for easy priming. It should be installed five to ten feet below the low- est level to which the water will drop while the pump is op- er ...

  • Sears 390.252158 - page 5

    INSTALLATION 1-1/4" 1-1/2" 2" Up to 25 Ft. 25 to 50 Ft. 50 to 200 Ft. Discharge Pipe Sizes When the pump is some distance from the house or point of water use, the discharge pipe size should be increased to reduce pressure losses caused by friction. 1" 1-114" 1-1/2" Up to 25 Ft. 25 to 100 Ft. 100 to 800 Ft. Tank Tanks ...

  • Sears 390.252158 - page 6

    ELECTRICAL Disconnect power before working on pump, motor, pressure switch, or wiring. Your Motor Terminal Board (under the motor end cover) if line voltage is 230 Volts or if you have a single voltage and Pressure Switch look like one of those shown below, motor: Connect power supply as shown for your type of Convert to 115 Volts as shown. Do not ...

  • Sears 390.252158 - page 7

    OPERATION Priming the Pump NOTICE: To properly prime the pump, install a pipe tee in the discharge piping (see Figure 1, Page 4). To prevent damage to internal-parts, do not start motor until pump has been filled with water. To prime pump: 1. Remove priming plug (Purchase separately; Figure 1, Page 4). 2. Fill pump with water. 3. Replace priming pl ...

  • Sears 390.252158 - page 8

    MAINTENANCE NOTICE: DO not overtighten; you may twist studs off of tank. If you have a torque wrench, tighten to 85 inch- pounds torque. 18. Stand tank on feet and reconnect piping. 19. Recharge tank to proper air pressure (see Page 5). 20. Reconnect hoses and pressure switch tube; prime pump (see Page 6). Air Valve Replacement 1. Follow steps 1 th ...

  • Sears 390.252158 - page 9

    MAINTENANCE 4. Place back half of pump on flat surface and tap out ce- ramic seat. See Figure 6. I. Screw impeller on shaft (clockwise) while holding shaft with 7/16" open end wrench on shaft flats. This will automatically locate seal in place. See Figure 8. 4790t94 Figure 6 5. Clean seal cavity. 6. Install new seal. A. Clean polished surface ...

  • Sears 390.252158 - page 10

    HELPFUL HINTS How to Handle a Gaseous Well In some areas well water contains gases which must be al- lowed to escape before the water is used. This can be done as shown in Figure 9. A good way of delivering gas-free water is to suspend a pipe, closed at the bottom and open at the top, surrounding the suction pipe. Since the gases rise in the well c ...

  • Sears 390.252158 - page 11

    TROUBLESHOOTING GUIDE TROUBLE POSSIBLE CAUSES REMEDIES Motor will not run 1. Disconnect switch is off 1. Be sure switch is on 2. Fuse is blown 2. Replace fuse 3. Starting switch is defective 3. Replace starting switch 4, Wires at motor are loose, 4. Refer to instructions on wiring disconnected, or wired incorrectly *5. Motor is wired incorrectly 5. ...

  • Sears 390.252158 - page 12

    REPAIR PARTS Pump Only - Model 390.252158 30 29 28 I 2 3 4 11 23 8 9 16 17 24 19 1c lO 2O 22 21 To Order Parts in the U.S.A., Call Sears Product Service, 1-800-366-7278 . TO Order Parts outside the U.S.A., Call Your local Sears Service Center or Store ...

  • Sears 390.252158 - page 13

    REPAIR PARTS Key Model 390.252158 Part No. 1/2 HP Description 1"* J218-953C 1A 1B 1C 1D 1E 2 3* 4 5 6 7 8 9 10 11 12 13 14 15 16 16 17 18 19 20 2:1" 22 23 24 25 26* 26A 27 28 29 3O U18-1103 U18-1180 U18-1098 U18-128 U 18-526 C69-2 U78-107PT WC78-41T L176-47P U9-399 U 109-6A J105-40PE J1-39P C19-54SS U9-201 N32P-66 N34P-19 N76-29P J20-18 N ...

  • Sears 390.252158 - page 14

    REPAIR PARTS Tank Only - Model 390.252158 7 REPAIR PARTS Model 390.252158 Key 1/2 HP Qty. No. Part Number Used 1 29135 1 2 3 4 5 6 7 U20-13 U212-160 t U31-446P U36-2.02BT 1 U78-777PA 1" U 19-55SS U74-37H U78-777P 1 1 1 6 1 2 1 1 Description Tank Assembly (Includes Diaphragm, Elbow, Valve, Nuts, Washers, & Inlet Flange) Bag - Vinyl Air Valv ...

  • Sears 390.252158 - page 15

    15 ...

  • Sears 390.252158 - page 16

    SEARS OWNER'S MANUAL Model No. 390.252158 The model number of your Shallow Well Water Systemwill be found on the pump body. When requesting service or ordering parts, always give the following information: • Product Type • Model Number • Part Number - • Part Description CRRFTJ;MRN ° PROFESSIONAL 1/2 HP SHALLOW WELL WATER SYSTEM For th ...

メーカー Sears カテゴリー Water System

Sears 390.252158のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 390.252158の取扱説明書
- Searsの製品カード
- パンフレット
- またはSears 390.252158の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Sears 390.252158の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Sears 390.252158の取り付け説明書、サービスマニュアル、簡易説明書、またはSears 390.252158のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Sears 390.252158の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Sears 390.252158デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがSears 390.252158を使用するのを助ける技術的文書のことです。説明書は通常、全てのSears 390.252158ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Searsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Sears 390.252158の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははSears 390.252158の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Sears 390.252158に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Sears 390.252158デバイスの基本機能を使うにあたってのヒント。 Sears 390.252158のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Sears 390.252158に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるSears 390.252158のメーカー/サービスへの連絡先に関する情報。

Sears 390.252158についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもSears 390.252158の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがSears 390.252158で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)