York STELLAR PLUS H4DH018 THRU 060の取扱説明書

20ページ 0.57 mb
ダウンロード

ページに移動 of 20

Summary
  • York STELLAR PLUS H4DH018 THRU 060 - page 1

    TECHNICAL GUIDE STELLAR PLUS TM SPLIT -SYSTEM AIR CONDITIONERS 12 SEER MODELS: H4DH018 THRU 060 (1.5 THRU 5 NOMINAL TONS) Due to contin uous product improv ement, specification s are subjec t to change without n otice. V isit us on the web at www .york.com for the m ost up-to-date te chnical informatio n. Additional r a ting i nformation can be f o ...

  • York STELLAR PLUS H4DH018 THRU 060 - page 2

    036-2102 0-003 Rev. C (0203) 2 Unitary Produ cts Group All dimensions are in i nches. They are subject to change without notice. Certified dimensions will be pr ovided upon request. Physi cal and El ectrical D at a MODE L H4DH018S06 H 4DH024S06 H4DH030S06 H4DH036S06 H4DH042S 06 H4DH048S06 H4DH060S06 Unit Supply V oltage 208/230 – 1 – 60 Normal ...

  • York STELLAR PLUS H4DH018 THRU 060 - page 3

    036-2102 0-003 Rev. C (0203) Unitary Pro ducts Group 3 Procedures: 1.Unit factor y charge liste d on the unit namep late includes refrigeran t for the c ondenser, the smallest e vaporator and for 1 5 f eet of interconnec ting line tubin g. 2.V er ify the orifice size and ad ditional char ge required f or specific eva porator coil in the system u si ...

  • York STELLAR PLUS H4DH018 THRU 060 - page 4

    036-2102 0-003 Rev. C (0203) 4 Unitary Produ cts Group - = No t appl icabl e COOLING CAP ACITY - With Air Handler Coils UNIT MODEL AIR HANDLER COI L 1 MODEL 1. G2FD co ils availabl e with a fa ctory ins talled horizo ntal drain pan. See pric e pages for specific m odel numbe r . COOLING MODEL ELEC TRIC 2 HEA T KW 2. Single phase units re quire sin ...

  • York STELLAR PLUS H4DH018 THRU 060 - page 5

    036-2102 0-003 Rev. C (0203) Unitary Pro ducts Group 5 COOLING CAP ACI TY - Upf l ow , Downflow, & Horizont al Furnaces and Coils * UNIT MODEL FURNACE** COIL MODE L COO LING CFM RANGE (MIN.-M AX.) W RA TED CFM NET MBH SEER W/O TXV SEER + TXV 1 EER TOTAL SE N S. H4DH018S06 575 725 14,17 G1F A024S14,17 650 18.2 13.7 12.20 - 10.60 14 G1F A030S 14 ...

  • York STELLAR PLUS H4DH018 THRU 060 - page 6

    036-2102 0-003 Rev. C (0203) 6 Unitary Produ cts Group * Require s a 2FD B lower Time Delay u nless a standa rd furn ace is equip ped with one. ** Refer to Quick Select ion Chart for sp ecific furnace match-up . H4DH042S06 1225 1575 17 G1F A048S 17 1400 41.0 30.8 12.15 - 10.70 21,24 G1F A048S21 1400 41.5 31.1 12.30 - 10.80 21,24 G1F A060S21,24 1400 ...

  • York STELLAR PLUS H4DH018 THRU 060 - page 7

    036-2102 0-003 Rev. C (0203) Unitary Pro ducts Group 7 COOLING CAP AC ITY - With V ar iable Speed Fu rnaces UN IT M ODEL V ARIABL E SPEED FURNACE MODE L COIL MODEL 1 W COO LING RA TED CFM NET MBH SEER W/O TXV SEER + TXV 2 EER TOTAL SE N S. 1 PH 12 SEER AC / P1DU / P1XD / P1XU - V ARIABLE SP EED 3 H4DH018S06 P1DUA12V G 1F A024S14 14 645 18.8 14.1 14 ...

  • York STELLAR PLUS H4DH018 THRU 060 - page 8

    036-2102 0-003 Rev. C (0203) 8 Unitary Produ cts Group For No tes see Pa ge 8. H4DH036S06 P1DUB16V G 1F A036S17 17 1220 35.8 26.5 13.00 - 1 1.80 P1DUB16V G 1F A048S17 17 1220 38.0 28.1 13.50 - 12.40 P1DUB16V G1HD036 - 1220 35.8 26.5 13. 00 - 1 1.65 P1DUB16V G1HD048 - 1220 38.5 28.5 13. 50 - 1 1.85 P1DUB16V G1UA 036S17 17 1220 35.8 26.5 13.00 - 1 1. ...

  • York STELLAR PLUS H4DH018 THRU 060 - page 9

    036-2102 0-003 Rev. C (0203) Unitary Pro ducts Group 9 H4DH048S06 P1DUB16V G 1F A048S17 17 1500 48.5 36.4 13.00 - 1 1.85 P1DUB16V G1UA 048S17 17 1500 48.5 36.4 13.00 - 1 1.85 P1DUC20V G1F A048S 21 21 1610 48.0 36.0 12. 45 - 1 1.20 P1DUC20V G1F A060S 21 21 1610 49.5 37.1 13. 30 - 1 1.60 P1DUC20V G1HD048 - 1610 49.0 36.8 12.25 - 1 1.35 P1DUC20V G1UA0 ...

  • York STELLAR PLUS H4DH018 THRU 060 - page 10

    036-2102 0-003 Rev. C (0203) 10 Unitary Produ cts Group 1. For co ndensin g unit only. Does not include effect of evap orator mo tor pow er or he at. 2. Perfo rmance ba sed on 15 ° superhe at and 15° sub-cooli ng at con densing unit . a. Increas e capacity 1% f or each 2° increas e in sub-coo ling. b. Decrease capacity 1% fo r each 2° de crease ...

  • York STELLAR PLUS H4DH018 THRU 060 - page 11

    036-2102 0-003 Rev. C (0203) Unitary Pro ducts Group 11 TYPICAL INST ALLA TIO N TYPICAL FIELD WIRING - 1 PHAS E APPLICATION L INST ALLA T ION THERMOST A T TO INDOOR BLOWER TO COI L NEC CLASS 2 WIRING NEC CLASS 1 WIRING TO POWER SUPPL Y WEA THERPROOF DISCONNECT SWITCH Seal open ing(s) wi th perma gum or equivale nt 24 ” SER VICE ACCESS CLEARANCE 4 ...

  • York STELLAR PLUS H4DH018 THRU 060 - page 12

    036-2102 0-003 Rev. C (0203) 12 Unitary Produ cts Group Multipliers for determining the performance with oth e r indoor sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H4DH018S06 INDOOR COIL MODEL NO. G1F A024S14,17 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 600 650 700 ID DB 85 80 75 70 85 80 75 70 85 80 75 70 ID WB 72 67 62 57 72 6 ...

  • York STELLAR PLUS H4DH018 THRU 060 - page 13

    036-2102 0-003 Rev. C (0203) Unitary Pro ducts Group 13 Multipliers for determining the performance with oth e r indoor sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H4DH024S06 INDOOR COIL MODEL NO. G1F A024S14,17 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 800 850 900 ID DB 85 80 75 70 85 80 75 70 85 80 75 70 ID WB 72 67 62 57 72 6 ...

  • York STELLAR PLUS H4DH018 THRU 060 - page 14

    036-2102 0-003 Rev. C (0203) 14 Unitary Produ cts Group Multipliers for determining the performance with oth e r indoor sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H4DH030S06 INDOOR COIL MODEL NO. G1F A036S17,21 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 980 1030 1080 ID DB 85 80 75 70 85 80 75 70 85 80 75 70 ID WB 72 67 62 57 72 ...

  • York STELLAR PLUS H4DH018 THRU 060 - page 15

    036-2102 0-003 Rev. C (0203) Unitary Pro ducts Group 15 Multipliers for determining the performance with oth e r indoor sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H4DH036S06 INDOOR COIL MODEL NO. G1F A036S17,21 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1 100 1200 1300 ID DB 85 80 75 70 85 80 75 70 85 80 75 70 ID WB 72 67 62 57 ...

  • York STELLAR PLUS H4DH018 THRU 060 - page 16

    036-2102 0-003 Rev. C (0203) 16 Unitary Produ cts Group Multipliers for determining the performance with oth e r indoor sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H4DH042S06 INDOOR COIL MODEL NO. G1F A048S17 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1300 1400 1500 ID DB 85 80 75 70 85 80 75 70 85 80 75 70 ID WB 72 67 62 57 72 6 ...

  • York STELLAR PLUS H4DH018 THRU 060 - page 17

    036-2102 0-003 Rev. C (0203) Unitary Pro ducts Group 17 Multipliers for determining the performance with oth e r indoor sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H4DH048S06 INDOOR COIL MODEL NO. G1F A048S21 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1450 1600 1750 ID DB 85 80 75 70 85 80 75 70 85 80 75 70 ID WB 72 67 62 57 72 6 ...

  • York STELLAR PLUS H4DH018 THRU 060 - page 18

    036-2102 0-003 Rev. C (0203) 18 Unitary Produ cts Group Multipliers for determining the performance with oth e r indoor sections. COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H4DH060S06 INDOOR COIL MODEL NO. G1F A060S21,24 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1600 1800 2000 ID DB 85 80 75 70 85 80 75 70 85 80 75 70 ID WB 72 67 62 57 7 ...

  • York STELLAR PLUS H4DH018 THRU 060 - page 19

    036-2102 0-003 Rev. C (0203) Unitary Pro ducts Group 19 MA TCHIN G INDOOR COMPONENTS G1UA 1/2 CASED UPFLOW G1HD HORIZONT AL DUCT G2FD* MUL TI-POSITION (UPFLOW , HORIZONT AL AND DOWNFLOW) * Available with factory inst alled horizontal drain pan. ADD-ON COILS - FOR FURNACE APPLICA TIONS G1NA UNCASED UPFLOW G1F A FULL CASED UPFLOW AIR HANDLERS - FOR N ...

  • York STELLAR PLUS H4DH018 THRU 060 - page 20

    Subject to change without notice. Printed in U.S.A. 036-21020-003 Rev. C ( 0203) Copyright © by York International Corp. 2003. All rights reserved. Supersedes: 036-21020-003 Rev. B (0702) Unit ary 5005 Norma n Product Y ork OK Group Drive 7306 9 NOTES ...

メーカー York カテゴリー Air Conditioner

York STELLAR PLUS H4DH018 THRU 060のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- STELLAR PLUS H4DH018 THRU 060の取扱説明書
- Yorkの製品カード
- パンフレット
- またはYork STELLAR PLUS H4DH018 THRU 060の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、York STELLAR PLUS H4DH018 THRU 060の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、York STELLAR PLUS H4DH018 THRU 060の取り付け説明書、サービスマニュアル、簡易説明書、またはYork STELLAR PLUS H4DH018 THRU 060のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、York STELLAR PLUS H4DH018 THRU 060の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

York STELLAR PLUS H4DH018 THRU 060デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがYork STELLAR PLUS H4DH018 THRU 060を使用するのを助ける技術的文書のことです。説明書は通常、全てのYork STELLAR PLUS H4DH018 THRU 060ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Yorkの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. York STELLAR PLUS H4DH018 THRU 060の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははYork STELLAR PLUS H4DH018 THRU 060の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。York STELLAR PLUS H4DH018 THRU 060に関してこのドキュメントで見つけることができる全てのヒントの目次
3. York STELLAR PLUS H4DH018 THRU 060デバイスの基本機能を使うにあたってのヒント。 York STELLAR PLUS H4DH018 THRU 060のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。York STELLAR PLUS H4DH018 THRU 060に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるYork STELLAR PLUS H4DH018 THRU 060のメーカー/サービスへの連絡先に関する情報。

York STELLAR PLUS H4DH018 THRU 060についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもYork STELLAR PLUS H4DH018 THRU 060の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがYork STELLAR PLUS H4DH018 THRU 060で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)