Generac Power Systems 004916-0の取扱説明書

44ページ 3.54 mb
ダウンロード

ページに移動 of 44

Summary
  • Generac Power Systems 004916-0 - page 1

    Installation and Owner’ s Man ual Air -cooled, Prepac ka ged A utomatic Standb y Generator s Model No. 004916-0 (10 kW NG, 11 kW LP) D ANGER DEADL Y EXHAUST FUMES. OUTDOOR INST ALLA TION ONL Y! Not intended for use as Primary P ower in place of utility or in life-support applications.   *This manual should remain with the unit. ...

  • Generac Power Systems 004916-0 - page 2

    I NTRODUCTION Thank you for purchasing this model of the Quiet Source product line by Generac P ower Systems Inc. This model is a compact, high performance, air - cooled, engine - driven generator designed to auto - matically supply electrical power to operate critical loads during a utility power failure. This unit is factory installed in an all-w ...

  • Generac Power Systems 004916-0 - page 3

    T able of Contents Air-cooled 1 1 kW Generators 1 Introduction ............................... Inside Front Cover Read This Manual Thoroughly ................................. IFC Contents .................................................................. IFC Operation and Maintenance ..................................... IFC How to Obtain Service ...

  • Generac Power Systems 004916-0 - page 4

    2 Study these SAFETY RULES carefully before install- ing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the unit. The generator can operate safely , efficiently and reliably only if it is properly installed, operated and maintained. Many accidents are caused by failing to follow simple and fundamental ru ...

  • Generac Power Systems 004916-0 - page 5

    3  ELECTRICAL HA Z AR DS  • All generators covered by this manual produce dangerous electrical voltages and can cause fatal electrical shock. Utility power delivers extremely high and dangerous voltages to the transfer switch as does the standby generator when it is in opera- tion. A void contact with bare wires, terminals, connections, etc ...

  • Generac Power Systems 004916-0 - page 6

    D ANGER  Only qualified electricians or contractors should attempt such installations, which must comply strictly with applicable codes, standards and regulations. 1.1 U N P A CKI NG/I NSP ECTION After unpacking, carefully inspect the contents for damage. • This standby generator set has been factory sup - plied with a weather protective enclo ...

  • Generac Power Systems 004916-0 - page 7

    Section 1 — General Information Air-cooled 1 1 kW Generators 5 1.5 TH E GEN ER A T OR Exh aust En c lo su r e O il Filte r Oil Di p stic k Air Filt er Batter y Compartmen t C ontrol Pane l D a t a D ecal Fuel Re g ulato r G F C I O utle t Figure 1.3 – 11 kW , V -twin GT -990 Engine 1.4.2 1 20 V OL T AC OUTLE T The generator is equipped with an ...

  • Generac Power Systems 004916-0 - page 8

    6 Section 1 — General Information Air-cooled 1 1 kW Generators 1.6 SP E CI F ICA TIONS 1.6.1 GEN ERA T OR Model 04916-0 Rated Max. Continuous P ower Capacity (W atts*) 10,000 NG/11,000 LP Rated V oltage 120/240 Rated Max. Continuous Load Current (Amps) 120 V olts** 83.3 NG/91.7 LP 240 V olts 41.7 NG/45.8 LP Main Line Circuit Breaker 45 Amp Phase ...

  • Generac Power Systems 004916-0 - page 9

    7 1.7 FUE L RE QUIRE MEN T S AN D R E COMM EN D A TIONS W ith LP gas, use only the vapor withdrawal sys - tem. This type of system uses the vapors formed above the liquid fuel in the storage tank. The engine has been fitted with a fuel carburetion system that meets the specifications of the 1997 California Air Resources Board for tamper -proof dual ...

  • Generac Power Systems 004916-0 - page 10

    1.1 0.2 TR ANSF ER SWIT CH This generator should only be installed with a com- patible transfer switch. A range of transfer switches are offered by the manufacturer . 1.1 1 BA TTER Y I NST ALLA TION  If the AUTO/OFF/MANUAL switch is not set to its OFF position, the generator can crank and start as soon as the battery cables are connected. If the ...

  • Generac Power Systems 004916-0 - page 11

    9 The following procedur es are to be observed: • Wear full eye pr otection and protective clothing; • Where electr olyte contacts the skin, wash it off immediately with water; • Where electr olyte contacts the eyes, flush thoroughly and immediately with water and seek medical attention; and • Spilled electrolyte is to be washed down with a ...

  • Generac Power Systems 004916-0 - page 12

    10 D ANGER  Proceed with caution! Generator power voltage is now supplied to the transfer switch. Contact with live transfer switch parts will result in dan- gerous and possibly fatal electrical shock. 10. Connect an accurate A C voltmeter and a fre - quency meter across transfer switch terminal lugs E1 and E2. V oltage should be 242-252 volts; ...

  • Generac Power Systems 004916-0 - page 13

    11 W ith the generator running and loads powered by generator AC output, turn ON the utility power supply to the transfer switch. The following should occur: • After about six seconds, the switch should transfer loads back to the utility power source. • About one minute after retransfer , the engine should shut down. 2.6 V OL T A GE R E GU L A ...

  • Generac Power Systems 004916-0 - page 14

    12 3.2.2 “OF F” POSITION This switch position shuts down the engine. This position also prevents automatic operation. 3.2.3 “MAN U AL ” POSITION Set the switch to Manual to crank and start the engine. Transfer to standby power will not occur unless there is a utility failure.  With the switch set to AUTO, the engine may crank and start a ...

  • Generac Power Systems 004916-0 - page 15

    13 Section 3 — Operation Air-cooled 1 1 kW Generators 3.5 SE T TI NG TH E EXERCISE TI M ER This generator is equipped with an exercise timer . Once it is set, the generator will start and exercise once every seven days, on the day of the week and at the time of day the following sequence is completed. During this exercise period, the unit runs fo ...

  • Generac Power Systems 004916-0 - page 16

    14 Section 4 — Maintenance Air-cooled 1 1 kW Generators 3.6.5 L OW BA T TER Y The microprocessor will continually monitor the bat - tery voltage and turn on the Low Battery LED if the battery voltage falls below 11.0 volts for one minute. Low battery voltage is a non-latching alarm, which will automatically clear if the battery voltage rises abov ...

  • Generac Power Systems 004916-0 - page 17

    15 Section 4 — Maintenance Air-cooled 1 1 kW Generators  Any attempt to crank or start the engine before it has been properly serviced with the r ecom- mended oil may result in an engine failur e. 4.3.2 OI L CHANGE PROCEDU R E T o change the oil, proceed as follows: 1. Run the engine until it is thoroughly warmed up then shut OFF the engine. 2 ...

  • Generac Power Systems 004916-0 - page 18

    16 Section 4 — Maintenance Air-cooled 1 1 kW Generators Figure 4.5 – Setting the Spark Plug Gap 4.7 B A T TER Y MAI NTENANCE The battery should be inspected per the “Service Schedule,” Section 4.13. The following procedure should be followed for inspection: 1. Inspect the battery posts and cables for tightness and corrosion. Tighten and cle ...

  • Generac Power Systems 004916-0 - page 19

    17 • Loosen the rocker jam nut. Use an 10mm allen wrench to turn the pivot ball stud while checking clearance between the rocker arm and the valve stem with a feeler gauge. Correct clearance is 0.002-0.004 inch (0.05-0.1 mm). NOTE: Hold the rocker arm jam nut in place as the pivot ball stud is turned. When valve clearance is correct, hold the piv ...

  • Generac Power Systems 004916-0 - page 20

    18 7. Remove the spark plug(s) and spray fogging agent into the spark plug(s) threaded openings. Reinstall and tighten the spark plug(s). 8. Remove the battery and store it in a cool, dry room on a wooden board. Never store the battery on any concrete or earthen floor . 9. Clean and wipe the entire generator . 4.1 2.2 R ETUR N T O SERVICE T o retur ...

  • Generac Power Systems 004916-0 - page 21

    19 Section 4 — Maintenance Air-cooled 1 1 kW Generators 4.1 3 SERVICE SCHEDU LE A TTENTION: It is recommended that all service work be performed by the nearest Authorized Dealer . SYSTEM/COMPONENT PROCEDURE FREQUENCY X = Action Inspect Change Clean W = W eekly R = Replace as Necessary M = Monthly * = Notify Dealer Y = Y early if Repair is Needed. ...

  • Generac Power Systems 004916-0 - page 22

    20 Section 5 — T roubleshooting Air-cooled 1 1 kW Generators 5.1 TROU B LE SHOO TI NG GU I DE Problem Cause Correction The engine will not crank. 1. F use blown. 1. Replace 15A fuse in generator control panel. 2. Loose, corroded or defective 2. Tighten, clean or replace battery cables. as necessary . 3. Defective starter motor . 3. * 4. Dead Batt ...

  • Generac Power Systems 004916-0 - page 23

    AIR OUTLET AIR INT AKE REAR VIEW RIGHT S IDE VIEW FRONT VIEW TOP VIEW (WITH ROOF OPEN) ( S ERVICE DOOR OPEN) "DO NO T LIFT BY THE ROOF" LIFTING HOLE S 4-CORNER S GROUNDING LUG **ALL DIMEN S ION S IN: MILLIMETER S [INCHE S ] ACCE SS TO OUTPUT CIRCUIT BREAKER AND TRAN S FER S WITCH CONNECTION S (REMOVE PLUG FOR A CCE SS ) 914mm [ 36.0" ...

  • Generac Power Systems 004916-0 - page 24

    22 Section 7 — Electrical Data Air-cooled 1 1 kW Generators Wiring Diagram – Drawing No. 0E7 071- B 14 66A 16 194 66 77 86 85 18 22 162 14 224B 2 1 L.E.D - ALARM INDICA TOR S 13 0 162 REGULA TOR BA TTERY CHARGER 13 3 1 2 VOLT A GE 0 6 0 162 4 6 0 OFF=60Hz 2 - S PA R E 1 - ON=50Hz 22 11 4 ON 22 4 11 2 D S W 1 15A J1 PRINTED CIRCUIT BOARD 13 2 56 ...

  • Generac Power Systems 004916-0 - page 25

    23 Section 7 — Electrical Data Air-cooled 1 1 kW Generators Wiring Diagram – Drawing No. 0E7 071- B CLO S E S T TO BEARING GRD 1 GRD 2 S TAT O R ENGINE WIRING 85 44 S WITCH CONT ACTOR OUTPUT TO TRAN S FER 240V GENERA TOR 11 EXTERNAL WHITE WHITE G G L 194 11 OUTLET HOT HO T L 3 1 LINE LOAD CB3 GFCI CONNECTION CU S TOMER CB1 4 G 5 2 N 11 11 44 0 ...

  • Generac Power Systems 004916-0 - page 26

    24 Section 7 — Electrical Data Air-cooled 1 1 kW Generators Electrical Schematic – Drawing No. 0E7 0 7 3-B 225B 224B 13 15 56 16 15B 56 239 86 15B PRINTED CIRCUIT 11 13 14 12 CONTROL BOARD 5 8 9 10 6 7 J1 2 3 4 1 VOLT AG E REGULA TOR ELECTRONIC MANUAL S W2 AUT O 239 15 S W1 194 194 15A F2 15A 194 6 162 4 0 4 11 22 56 15 0 0 13 0 CHARGER 2 1 0 B ...

  • Generac Power Systems 004916-0 - page 27

    25 Section 7 — Electrical Data Air-cooled 1 1 kW Generators Electrical Schematic – Drawing No. 0E7 0 7 3-B WINDING CB3 - CIRCUIT BREAKER, EXTERNAL OUTLET , PU S H/PULL 22 22 225A 56V A 225A 224A 224 225 225 224 14 77 66 224A N1 1V A 14 TX N2 0 0 23 224B 225B 194 22 0 1 7 2 16 14 11 0 0 4 6 0 0 0 BCR 6 7 3 9 4 9 G 22 0 F S 62 0 0 11 16 13 4 BCR ...

  • Generac Power Systems 004916-0 - page 28

    26 60 9 5 7 3 60 2 0 72 21 1 5 51 5 3 54 6 9 7 6 77 7 5 17 4 8 47 4 9 52 5 0 55 46 17 67 3 1 8 5 7 3 44 74 42 38 27 1 8 2 6 7 0 2 5 2 8 2 3 2 9 9 17 22 " A" 1 5 14 3 7 3 4 " A" 41 17 17 8 7 8 6 3 0 1 6 3 7 4 3 1 7 60 27 8 4 33 33 17 3 2 3 5 4 0 9 6 6 3 6 24 11 5 8 8 8 83 7 64 62 65 1 3 4 8 3 6 7 9 2 3 66 5 1 64 6 8 8 Section 8 ? ...

  • Generac Power Systems 004916-0 - page 29

    27 ITEM P ART NO . QTY . DESCRIPTION 1 0E7325 4 HHF S , 1/4"-20 X 5/8" GRADE 5 4 0E6884 1 S EAL, AL TERNA T OR S HAFT 5 0E4706A 1 S OUND BAFFLE INT AKE S CROLL 6 0D1131 1 GUARD ,F AN 7 0E4706 1 S CROLL, INT AKE 8 0C2824 11 S CREW T AP-R #10-32 X 9/16" 9 039253 6 S CREW HHC M8-1.25 X 20 10 0A8250 1 S CREW HHC 3/8"-24 X 2" G8 ...

  • Generac Power Systems 004916-0 - page 30

    28 2 9 47 4 3 4 2 5 24 4 0 2 5 2 5 33 54 4 8 8 7 4 8 46 47 4 3 3 8 7 1 8 2 1 0 11 , 1 3 9 50 60 3 6 3 2 3 5 39 50 3 2 33 39 61 62 3 1 3 2 2 6 57 1 9 9 22 6 3 1 6 11 , 1 2 5 9 5 8 17 1 6 15 2 0 56 2 0 22 2 4 3 0 51 3 1 3 2 27 21 8 8 7 20 1 6 64 65 6 52 Section 8 — Exploded Views and P arts Lists Air-cooled 1 1 kW Generators Control Panel – Drawi ...

  • Generac Power Systems 004916-0 - page 31

    29 ITEM P ART NO . QTY . DESCRIPTION 1 0E3312 1 A SS EMBL Y , HOME S T ANDBY CONTROLLER 2 0A1801 1 A SS EMBL Y , BA TTER Y CHARGER ENGINE 3 083049 1 A SS EMBL Y , PO TTED REGULA TOR 4 092036 8 PPHM S /L W #6-32 X 1/4" LONG 5 0D3062A 4 HEX S T AND-OFF #6-32 X 3/4" 6 075235 4 S CREW HHC M5-0.8 X 30mm 7 049226 6 WA S HER LOCK M5 8 051716 6 N ...

  • Generac Power Systems 004916-0 - page 32

    30 5 3 4 0 3 5 3 7 39 38 54 41 42 56 55 50 51 17 2 33 3 1 3 0 3 4 2 6 2 8 27 3 2 9 1 8 4 2 5 5 4 1 3 2 3 6 44 45 4 3 47 4 9 1 6 14 52 1 9 1 5 6 2 3 21 22 12 9 1 0 7 11 8 Section 8 — Exploded Views and P arts Lists Air-cooled 1 1 kW Generators GT -990 Eng ine – Drawing No. 0F2000 ...

  • Generac Power Systems 004916-0 - page 33

    31 ITEM P ART NO . QTY . DESCRIPTION 1 0C5730A 1 A SS EMBL Y , CRANKCA S E RV 2 0E9843 1 S EAL, 38 I.D . CRANKCA S E 3 090388 6 S CREW , HHTT M6-1.0 X 12mm 4 0C5372 1 A SS EMBL Y , BREA THER 5 0C3005 1 GA S KET , BREA THER COVER 6 0E3372A 1 S EP ARA TOR, OIL BREA THER 7 0D8067A 1 A SS EMBL Y , HEAD #1 8 0C2981C 1 CO VER, ROCKER 9 071983 4 RET AINER ...

  • Generac Power Systems 004916-0 - page 34

    32 50 25 7 19 1 19 24 23 18 19 21 22 2 19 1 16 5 15 17 1 14 13 12 11 8 3 20 1 67 65 58 44 34 28 27 26 32 31 29 39 30 35 33 38 57 53 37 52 "B" 49 36 51 1 92 54 55 19 40 43 44 44 50 44 48 47 46 101 91 97 41 100 99 42 82 76 69 66 6 64 56 63 10 9 4 71 68 70 75 74 62 73 43 77 79 78 98 44 51 85 84 87 89 81 45 "B" 72 80 88 83 86 59 80 ...

  • Generac Power Systems 004916-0 - page 35

    33 Section 8 — Exploded Views and P arts Lists Air-cooled 1 1 kW Generators Engine Accessories – Drawing No. 0F200 1 -D ITEM P ART NO . QTY . DESCRIPTION 1 045756 11 S CREW HHTT M6-1.0 X 10 YC 2 0D1131 1 GUARD , F AN 3 0F1169G 1 HOU S ING, BLO WER V -TWIN R V 4 0C9763 4 NUT ,GROMMET 1/4 PLUG 5 0E4386 1 TUBE, INT AKE 6 0E5079 1 HO S E, BREA THER ...

  • Generac Power Systems 004916-0 - page 36

    34 26 3 0 24 9 1 2 3 10 22 21 11 2 8 27 3 1 42 41 44 40 39 38 51 5 20 1 8 14 15 3 1 7 16 33 3 2 1 9 8 6 4 2 3 4 3 3 4 5 12 4 38 4 3 47 46 4 8 5 3 50 4 9 25 3 7 38 3 6 3 5 3 Section 8 — Exploded Views and P arts Lists Air-cooled 1 1 kW Generators Alternator & Pulleys – Drawing No. 0E4880 ...

  • Generac Power Systems 004916-0 - page 37

    35 Section 8 — Exploded Views and P arts Lists Air-cooled 1 1 kW Generators Alternator & Pulleys – Drawing No. 0E4880 ITEM P ART NO . QTY . DESCRIPTION 1 0E0196A 1 FRAME, MOUNTING SS H S B 2 022129 7 W A S HER LOCK M8-5/16 3 022145 8 W A S HER FLA T 5/16-M8 ZINC 4 022259 4 NUT HEX 5/16-18 S TEEL 5 0C7758 4 VIB MNT 1.5 X 1.38 X 5/16-18 6 0C3 ...

  • Generac Power Systems 004916-0 - page 38

    36 17 9 20 28 25 21 24 19 11 10 23 22 22 15 26 14 13 16 12 18 8 29 9 30 27 4 5 3 2 17 1 26 15 14 16 13 19 21 25 20 24 12 18 23 Section 8 — Exploded Views and P arts Lists Air-cooled 1 1 kW Generators Regulator – Drawing No. 0E488 1 -C ...

  • Generac Power Systems 004916-0 - page 39

    37 ITEM P ART NO . QTY . DESCRIPTION 1 0D5694 1 CA S TING, TWIN REGULA TOR HOU S ING 2 0F5022 1 S OLENOID COIL, 12VDC 3 0C4647 1 GA S KET , S OLENOID 4 0C4680 1 PLUNGER, LP REGULA T OR A SS EMBL Y 5 0C6070 1 S PRING- S OLENOID , PLUNGER 8 0F4795 4 S CREW PPHM S EM S M4-0.7 X 10 9 0D3973 2 PLUG, EXP AN S ION 16mm 10 0E6183 2 ELBOW 90D S TREET 1/2” ...

  • Generac Power Systems 004916-0 - page 40

    38 Section 9 — Notes Air-cooled 1 1 kW Generators ...

  • Generac Power Systems 004916-0 - page 41

    39 Section 9 — Notes Air-cooled 1 1 kW Generators ...

  • Generac Power Systems 004916-0 - page 42

    40 CALI FOR N IA EM ISSION C ONTROL W AR R ANT Y ST A TEMENT Y OU R W AR RANT Y R IGHTS AND OB LIGA TIONS The California Air Resources Board (CARB) and Generac P ower Systems, Inc. (Generac) are pleased to explain the Emission Control System W arranty on your new engine. * In California, new utility , and lawn and garden equipment engines must be d ...

  • Generac Power Systems 004916-0 - page 43

    41 EM IS SION CONTROL S YSTEM W AR R ANT Y Emission Control System W arranty (ECS W arranty) for 1995 and later model year engines: (a) Applicability: This warranty shall apply to 1995 and later model year engines. The ECS W arranty Period shall begin on the date the new engine or equipment is purchased by/delivered to its original, end-use purchas ...

  • Generac Power Systems 004916-0 - page 44

    Part No. 0E4885 Revision E (12/06/05) Printed in U.S.A. Section 1 0 – W arranty Air-cooled 1 1 kW Generators GENERA C PO WER SYSTEMS “TWO YEAR” LIMITED W ARRANTY FOR QUIETSOURCE™ “PREP ACKA GED EMERGENCY A UT OMA TIC ST ANDBY GENERA T ORS” F or a period of two years from the date of original sale, Generac P ower Systems , Inc. (Generac) ...

メーカー Generac Power Systems カテゴリー Portable Generator

Generac Power Systems 004916-0のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 004916-0の取扱説明書
- Generac Power Systemsの製品カード
- パンフレット
- またはGenerac Power Systems 004916-0の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Generac Power Systems 004916-0の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Generac Power Systems 004916-0の取り付け説明書、サービスマニュアル、簡易説明書、またはGenerac Power Systems 004916-0のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Generac Power Systems 004916-0の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Generac Power Systems 004916-0デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGenerac Power Systems 004916-0を使用するのを助ける技術的文書のことです。説明書は通常、全てのGenerac Power Systems 004916-0ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Generac Power Systemsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Generac Power Systems 004916-0の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGenerac Power Systems 004916-0の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Generac Power Systems 004916-0に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Generac Power Systems 004916-0デバイスの基本機能を使うにあたってのヒント。 Generac Power Systems 004916-0のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Generac Power Systems 004916-0に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGenerac Power Systems 004916-0のメーカー/サービスへの連絡先に関する情報。

Generac Power Systems 004916-0についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGenerac Power Systems 004916-0の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGenerac Power Systems 004916-0で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)