American Water Heater BCG3-80T150-6NOXの取扱説明書

32ページ 0.63 mb
ダウンロード

ページに移動 of 32

Summary
  • American Water Heater BCG3-80T150-6NOX - page 1

    1 MODELS BCG3 & ABCG3 LOW NOx COMMERCIAL GAS, GLASS-LINED, TANK-TYPE WATER HEATER • INSTALLATION • OPERATION • MAINTENANCE • LIMITED WARRANTY PLACE THESE INSTRUCTIONS ADJACENT TO HEATER AND NOTIFY OWNER TO KEEP FOR FUTURE REFERENCE. CAUTION TEXT PRINTED OR OUTLINED IN RED CONT AINS INFORMA TION RELA TIVE TO YOUR SAFETY . PLEASE READ THO ...

  • American Water Heater BCG3-80T150-6NOX - page 2

    2 ROUGH-IN-DIMENSIONS FRONT VIEW TO P VIEW BACK VIEW F TOP OUTLET 1 1/2” NPT TOP INLET 1 1/2” NPT T ABLE 1. ROUGH-IN-DIMENSIONS T ABLE 2. RECOVERY CAP ACITIES, based on 80% efficiency T ABLE 3. GAS AND ELECTRICAL CHARACTERISTICS ...

  • American Water Heater BCG3-80T150-6NOX - page 3

    3 T ABLE OF CONTENTS ROUGH-IN-DIMENSIONS -------------------------------- 2 FOREWORD ------------------------------------------------- 3 GENERAL SAFETY INFORMA TION ------------------- 4 Precautions --------------------------------------------------- 4 Grounding Instructions ------------------------------------- 4 Chemical V apor Corrosion -------- ...

  • American Water Heater BCG3-80T150-6NOX - page 4

    4 GENERAL SAFETY INFORMA TION PRECAUTIONS DO NOT USE THIS APPLIANCE IF ANY P AR T HAS BEEN UNDER WA TER. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water . IF THE UNIT IS EXPOSED TO THE FOLLOWING , DO NOT OPERA TE HEA TER UNTIL ALL C ...

  • American Water Heater BCG3-80T150-6NOX - page 5

    5 HIGH AL TITUDE INST ALLA TIONS WARNING INST ALLA TIONS ABOVE 2000 FEET (610 METERS) REQUIRE REPLACEMENT OF THE BURNER ORIFICE IN ACCORDANCE WITH SECTION 1 1.1.2 OF THE NA TIONAL FUEL GAS CODE (ANSI Z223.1). F AILURE TO REPLACE THE ORIFICE WILL RESUL T IN IMPROPER AND INEFFICIENT OPERA TION OF THE APPLIANCE RESUL TING IN THE PRODUCTION OF INCREASE ...

  • American Water Heater BCG3-80T150-6NOX - page 6

    6 The exhaust inducer is equipped with a gravity controlled damper to reduce the amount of heat loss through the flue, improving efficiency . EXHAUST INDUCER FIGURE 4 CIRCULA TING PUMP A circulating pump is used when a system requires a circulating loop or there is a storage tank used in conjunction with the heater . Refer to the piping diagrams in ...

  • American Water Heater BCG3-80T150-6NOX - page 7

    7 length and width at least 2" greater than the diameter of the heater and must be piped to an adequate drain. The pan must not restrict combustion air flow . LEVELING If the unit is not level, insert the bolts which were used in crating into the legs to correct this condition. CLEARANCES These heaters are approved for installation on combusti ...

  • American Water Heater BCG3-80T150-6NOX - page 8

    8 BURNERS AND FLUE TUBES AND CREA TES A RISK OF ASPHYXIA TION. Where an exhaust fan is supplied in the same room with a heater , sufficient openings for air must be provided in the walls. UNDERSIZED OPENINGS WILL CAUSE AIR TO BE DRA WN INTO THE ROOM THROUGH THE CHIMNEY , CAUSING POOR COMBUSTION. SOOTING MA Y RESUL T IN SERIOUS DAMAGE TO THE HEA TER ...

  • American Water Heater BCG3-80T150-6NOX - page 9

    9 TYPE B GAS VENT Multiple Gas Fired T ank-T ype Heaters When venting multiple tank type heaters using T ype B vent pipe, follow the installation diagram (figure 4) and tables below which give sizing and dat a based upon NFP A 54/ANSI Z223. 1992. T ABLE 6. TECHNICAL DA T A VENTING MODEL BCG3-80T150-6NOX Input: 154,000 Btu/hr T otal V ent Height (Fe ...

  • American Water Heater BCG3-80T150-6NOX - page 10

    10 W A TER LINE CONNECTIONS This manual provides detailed installation diagrams (see p ages 13-19 of this manual) for typical methods of application for the water heater(s). The water heater may be installed by itself, or with a separate storage tank, on both single and two-temperature systems. When used with a separate storage tank, the circulatio ...

  • American Water Heater BCG3-80T150-6NOX - page 11

    11 INST ALLA TION DIAGRAMS-TOP INLET/OUTLET USAGE Use of the top inlet water connection requires installation of an inlet dip tube (refer to figure 8). The tube is supplied in the heater . Follow caution labels if applying heat to this fitting. Do not allow pipe dope to contact the plastic tube during installation. CODE RESTRICTIONS Use of the top ...

  • American Water Heater BCG3-80T150-6NOX - page 12

    12 VERTICAL ST ORAGE T ANK AND FORCED CIRCULA TION DANGER TEMPERA TURE SETTING SHOULD NOT EXCEED SAFE USE TEMPERA TURE A T FIXTURES. SEE WA TER TEMPERA TURE CONTROL WARNING ON P AGE 25. IF HIGHER PREHEA T TEMPERATURES ARE NECESSARY TO OBT AIN ADEQUATE BOOSTER OUTPUT , ADD AN ANTI-SCALD V AL VE FOR HOT WA TER SUPPLIED TO FIXTURES. HORIZONT A L STORA ...

  • American Water Heater BCG3-80T150-6NOX - page 13

    13 DANGER TEMPERA TURE SETTING SHOULD NOT EXCEED SAFE USE TEMPERA TURE A T FIXTURES. SEE WA TER TEMPERA TURE CONTROL WARNING ON P AGE 25. IF HIGHER PREHEAT TEMPERA TURES ARE NECESSARY TO OBT AIN ADEQUA TE BOOSTER OUTPUT , ADD AN ANTI- SCALD V AL VE FOR HOT W A TER SUPPLIED TO FIXTURES. TWO TEMPERA TURE - ONE HEA TER HIGH TEMPERA TURE STORAGE WITH R ...

  • American Water Heater BCG3-80T150-6NOX - page 14

    14 INST ALLA TION DIAGRAMS-SIDE INLET/OUTLET USAGE DANGER TEMPERA TURE SETTING SHOULD NOT EXCEED SAFE USE TEMPERA TURE A T FIXTURES. SEE WA TER TEMPERA TURE CONTROL WARNING ON P AGE 25. IF HIGHER PREHEAT TEMPERA TURES ARE NECESSARY T O OBT AIN ADEQUA TE BOOSTER OUTPUT , ADD AN ANTI- SCALD V AL VE FOR HOT WA TER SUPPLIED TO FIXTURES. A listed temper ...

  • American Water Heater BCG3-80T150-6NOX - page 15

    15 ONE OR TWO TEMPERATURE - ONE HEATERS,HIGH TEMPERATURE STORAGE WITH OR WITHOUT RECIRCULATION HEATER WITH OR WITHOUT MIXING VALVE HEATER WITH MIXING VALVE AND RECIRCULATED SANITIZING LOOP NOTE 1: T OGGLE SWITCH CONTROLS 180°F (82°C) WA TER CIRCULA TION. INST ALL ON OR CLOSE TO DISHW ASHING MACHINE. T OGGLE SWITCH MUST BE CLOSED (ON) DURING THE R ...

  • American Water Heater BCG3-80T150-6NOX - page 16

    16 TWO TEMPERATURE - TWO PRE-HEATERS WITH MIXING VALVE OR BOOSTER HEATER WITH OR WITHOUT BUILING RECIRCULATION TWO PRE-HEATERS WITH MIXING VALVE TWO PRE-HEATERS WITH BOOSTER HEATER DANGER TEMPERA TURE SETTING SHOULD NOT EXCEED SAFE USE TEMPERA TURE A T FIXTURES. SEE W A TER TEMPERA TURE CONTROL W ARNING ON P AGE 25. IF HIGHER PREHEA T TEMPERA TURES ...

  • American Water Heater BCG3-80T150-6NOX - page 17

    17 MEDIUM TEMPERATURE - ONE HEATER WITH AUXILIARY STORAGE TANK FORCED CIRCULATION WITH OR WITHOUT BUILDING RECIRCULATION VERTICAL STORAGE TANK HORIZONTAL STORAGE TANK DANGER TEMPERA TURE SETTING SHOULD NOT EXCEED SAFE USE TEMPERA TURE A T FIXTURES. SEE WA TER TEMPERA TURE CONTROL W ARNING ON PAGE 25. IF HIGHER PREHEA T TEMPERA TURES ARE NECESSARY T ...

  • American Water Heater BCG3-80T150-6NOX - page 18

    18 FIGURE 9 - SINGLE UNIT WIRING DIAGRAM ...

  • American Water Heater BCG3-80T150-6NOX - page 19

    19 GAS PIPING Contact your local gas service company to ensure that adequate gas service is available and to review applicable installation codes for your area. Size the main gas line in accordance with T able 3. The figures shown are for straight lengths of pipe at 0.5 in. W .C. pressure drop, which is considered normal for low pressure systems. N ...

  • American Water Heater BCG3-80T150-6NOX - page 20

    20 correct water column pressure allowing for a nominal pressure drop through the controls. The minimum gas supply pressure for input adjustment must not be less than 4.5" w .c. (1.12 kPa) for natural gas. Do not subject the combination gas valve to inlet gas pressures of more than 14.0" W .C. (3.48 kPa) - natural gas. A service regulator ...

  • American Water Heater BCG3-80T150-6NOX - page 21

    21 SEQUENCE OF OPERA TION The following information will describe the Sequence of Operation for this appliance. 1. Switch power on to unit. 2. Thermostat calls for heat. 3. Ignition Control Board performs diagnostic check on system component s. 4. On completion of diagnostics check, the Ignition Control Board sends signal to Exhaust Inducer . 5. Ex ...

  • American Water Heater BCG3-80T150-6NOX - page 22

    22 A . This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner . Do not try to light the burner by hand. B. BEFORE OPERA TING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor . “WHA T TO DO IF ...

  • American Water Heater BCG3-80T150-6NOX - page 23

    23 W A TER TEMPERA TURE CONTROL DANGER THIS W ATER HEA TER IS EQUIPPED WITH AN ADJUST ABLE THERMOST A T TO CONTROL W A TER TEMPERA TURE. HOT W A TER TEMPERA TURES REQUIRED FOR AUT OMA TIC DISHW ASHER AND LAUNDR Y USE CAN CAUSE SCALD BURNS RESUL TING IN SERIOUS PERSONAL INJURY AND/ OR DEA TH. THE TEMPERA TURE A T WHICH INJURY OCCURS V ARIES WITH THE ...

  • American Water Heater BCG3-80T150-6NOX - page 24

    24 Servicing of the ignitor assembly includes keeping the ignitor free of lint, scale or any other foreign debris. FIGURE 11, IGNITOR MAIN BURNER The main burner , fig.12, should display the following characteristics: • Cause rapid ignition and carry across entire burner . • Give reasonably quiet operation during ignition, burning, and extincti ...

  • American Water Heater BCG3-80T150-6NOX - page 25

    25 When the heater is operating at full capacity , or full gas input, it should consume 1 cu. ft. of gas in time indicated on T able 9. VENTING SYSTEM Examine the venting system every six months for obstructions and/or deterioration of the vent piping. Remove all soot or other obstructions from chimney which will ret ard free draft. REMOTE STORAGE ...

  • American Water Heater BCG3-80T150-6NOX - page 26

    26 1. Once a month the heater should be flushed. Open the drain valve and allow two gallons of water to drain from the heater . Inlet water valve should remain open to maint ain pressure in tank. 2. A cleanout opening is provided for periodic cleaning of the t ank. Gas must be shut off and heater drained before opening cleanout. T o clean heater th ...

  • American Water Heater BCG3-80T150-6NOX - page 27

    27 — It is possible that the high limit (E.C.O.) has functioned to shut off the appliance. See FEA TURES — Water T emperature Control for reset procedure. Contact your serviceman if limit continues to function to shut off appliance. SYSTEM DIAGNOSTICS Y our water heater is equipped with an ignition module that incorporates a diagnostic system t ...

  • American Water Heater BCG3-80T150-6NOX - page 28

    28 SEQUENCE OF OPERA TION FLOW CHART Description of this flow chart can be found in the “SEQUENCE OF OPERA TION” section. Switch power on to unit. Thermostat calls for heat. Ignition Control Board performs diagnostic check on components Ignition Control Board sends power to Exhaust Inducer Exhaust Inducer engages Prover Switch Ignition Control ...

  • American Water Heater BCG3-80T150-6NOX - page 29

    29 REMEDY COMPLAINT CAUSE USER SERVICEMAN *W ater not hot enough. Thermostat set too low. Set thermost at dial to a higher temperature. Thermostat out of calibration. Call serviceman Recalibrate thermostat. If thermostat cannot be recalibrated, replace. *Insufficient hot water Thermostat set too low. Set thermost at dial to a higher *See WA TER TEM ...

  • American Water Heater BCG3-80T150-6NOX - page 30

    30 NOTES: ...

  • American Water Heater BCG3-80T150-6NOX - page 31

    31 Model BCG3 & ABCG3 Limited Warranty American W ater Heater, the warrantor , extends the following LIMITED W ARRANTY to the owner of this water heater . 1. THE T ANK If the glass-lined tank in this water heater shall prove upon examination by the warrantor to have leaked due to natural corrosion from potable water therein, during the first TH ...

  • American Water Heater BCG3-80T150-6NOX - page 32

    32 ...

メーカー American Water Heater カテゴリー Water Heater

American Water Heater BCG3-80T150-6NOXのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- BCG3-80T150-6NOXの取扱説明書
- American Water Heaterの製品カード
- パンフレット
- またはAmerican Water Heater BCG3-80T150-6NOXの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、American Water Heater BCG3-80T150-6NOXの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、American Water Heater BCG3-80T150-6NOXの取り付け説明書、サービスマニュアル、簡易説明書、またはAmerican Water Heater BCG3-80T150-6NOXのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、American Water Heater BCG3-80T150-6NOXの製品を使用するにあたって最も人気のある説明書を閲覧できます。

American Water Heater BCG3-80T150-6NOXデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAmerican Water Heater BCG3-80T150-6NOXを使用するのを助ける技術的文書のことです。説明書は通常、全てのAmerican Water Heater BCG3-80T150-6NOXユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

American Water Heaterの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. American Water Heater BCG3-80T150-6NOXの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAmerican Water Heater BCG3-80T150-6NOXの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。American Water Heater BCG3-80T150-6NOXに関してこのドキュメントで見つけることができる全てのヒントの目次
3. American Water Heater BCG3-80T150-6NOXデバイスの基本機能を使うにあたってのヒント。 American Water Heater BCG3-80T150-6NOXのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。American Water Heater BCG3-80T150-6NOXに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAmerican Water Heater BCG3-80T150-6NOXのメーカー/サービスへの連絡先に関する情報。

American Water Heater BCG3-80T150-6NOXについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAmerican Water Heater BCG3-80T150-6NOXの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAmerican Water Heater BCG3-80T150-6NOXで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)