Echo PB-620STの取扱説明書

28ページ 1.16 mb
ダウンロード

ページに移動 of 28

Summary
  • Echo PB-620ST - page 1

    Power Blower Operator's Manual MODEL PB-620ST W ARNING Read rules for safe operation and all instructions carefully . ECHO provides this Operator's Manual, which must be read and understood for proper and safe opera- tion. X753003741 1 1/09 X7531 123401 ...

  • Echo PB-620ST - page 2

    2 Copyright© 2010 By Echo, Incorporated All Rights Reserved. t h e o p e r a t o r ' s m a n u a l Read and understand this manual before operation. Keep it in a safe place for future reference. It contains specications and information for operation, starting, stopping, maintenance, storage, and assembly specic to this product. t a b l ...

  • Echo PB-620ST - page 3

    3 P o w e r B l o w e r o P e r a t o r ' s M a n u a l I n t e r n a t I o n a l s y m b o l s p e r s o n a l C o n d I t I o n a n d s a f e t y e q u I p m e n t W ARNING Power Blower users risk injury to themselves and others if the power blower is used improperly or safety precautions are not followed. Proper clothing and safety gear mus ...

  • Echo PB-620ST - page 4

    4 Physical Condition Y our judgment and physical dexterity may not be good: • if you are tired or sick, • if you are taking medication, • if you have taken alcohol or drugs. Operate unit only if you are physically and mentally well. Eye Protection W ear eye protection that meets ANSI Z87.1 or CE requirements whenever you operate the unit. Han ...

  • Echo PB-620ST - page 5

    5 P o w e r B l o w e r o P e r a t o r ' s M a n u a l DANGER Do not operate this product indoors or in inadequately ventilated areas. Engine exhaust contains poisonous emissions and can cause serious injury or death. Read the Manuals • Provide all users of this equipment with the Operator ’ s Manual and Safety Manual for instructions on ...

  • Echo PB-620ST - page 6

    6 PRODUCT EMISSION DURABILITY (EMISSION COMPLIANCE PERIOD) The 300 hour emission compliance period is the time span selected by the manufacturer certifying the engine emis- sions output meets applicable emissions regulations, provided that approved maintenance procedures are followed as listed in the Maintenance Section of this manual. e q u I p m ...

  • Echo PB-620ST - page 7

    7 P o w e r B l o w e r o P e r a t o r ' s M a n u a l Locate the safety decals on your unit. Make sure the decals are legible and that you understand and follow the instruc- tions on them. If a decal cannot be read, a new one can be ordered from your ECHO dealer . See P AR TS ORDERING instructions for specic information. d e s C r I p t I ...

  • Echo PB-620ST - page 8

    8 1. SAFETY DECAL - Lists important safety precautions. 2. SP ARK PLUG - Provides spark to ignite fuel mixture. 3. SP ARK ARRESTOR MUFFLER OR SP ARK ARRESTOR MUFFLER WITH CA T AL YST - The mufer or catalytic mufer controls exhaust noise and emission. The spark arrestor screen prevents hot, glowing particles of carbon from leaving the mufer ...

  • Echo PB-620ST - page 9

    9 P o w e r B l o w e r o P e r a t o r ' s M a n u a l C o n t e n t s ____ 1 - Power Head ____ 1 - Flex Pipe ____ 1 - Pipe w/swivel ____ 1 - Straight Pipe ____ 1 - Straight Pipe w/decal ____ 1 - Operator's Manual ____ 1 - W arranty Registration Card ____ 1 - Plastic Bag ____ 2 - Clamps w/screws ____ 1 - Guide Loop W ARNING Never perform ...

  • Echo PB-620ST - page 10

    10 5. Assemble exible pipe (B) to elbow (D) on blower and tighten clamps (A). Position guide loop (G) on inside (blower side) of exible tube. NOTE A light lubricant may be used to ease assembly of exible pipe to blower elbow . 6. Clip throttle cable into throttle cable guide loop (G). 7. Move handle (E) to desired position. T ighten knob ( ...

  • Echo PB-620ST - page 11

    11 P o w e r B l o w e r o P e r a t o r ' s M a n u a l Fuel Requirements Gasoline - Use 89 Octane [R+M/2] (mid grade or higher) gasoline known to be good quality . Gasoline may contain up to 10% Ethanol (grain alcohol) or 15% MTBE (methyl tertiary-butyl ether). Gasoline containing methanol (wood alcohol) is NOT approved. T wo Stroke Oil - A ...

  • Echo PB-620ST - page 12

    12 IMPOR T ANT Stored fuel ages. Do not mix more fuel than you expect to use in thirty (30) days, ninety (90) days when a fuel sta- bilizer is added. IMPOR T ANT Stored two-stroke fuel may separate. AL W A YS shake fuel container thor- oughly before each use. After use • DO NOT store a unit with fuel in its tank. Leaks can occur . Return unused f ...

  • Echo PB-620ST - page 13

    13 P o w e r B l o w e r o P e r a t o r ' s M a n u a l s t a r t I n g w a r m e n g I n e The starting procedure is the same as Cold Start except DO NOT close the choke. 1. Thr ottle Position/Stop Switch Button Slide Throttle Position /Stop Switch Button (A) back to idle posi- tion (rst detent away from stop position). 2. Pur ge Bulb Pum ...

  • Echo PB-620ST - page 14

    14 IMPOR T ANT Use reduced speed only when performing light-duty tasks or to comply with local noise regulations. Continuous low speed opera- tion may allow fuel/oil residue to build-up on the piston and cause rapid build-up of carbon on the spark arrestor screen, resulting in overheating and engine damage. T o reduce harmful build-up, run engine a ...

  • Echo PB-620ST - page 15

    15 P o w e r B l o w e r o P e r a t o r ' s M a n u a l m a I n t e n a n C e W ARNING Moving parts can amputate ngers or cause severe injuries. Keep hands, clothing and loose objects away from all openings. Always stop engine, disconnect spark plug, and make sure all moving parts have come to a complete stop before removing obstructions, ...

  • Echo PB-620ST - page 16

    16 a I r f I l t e r Level 1. T ools r equired: 25 - 50 mm (1 - 2 in.) Cleaning brush. Parts r equir ed: REPOWER TM T une Up Kit NOTE Clean daily . 1. Close choke (Cold Start Position ( ). This prevents dirt from entering the carburetor throat when the air lter is removed. Brush accumulated dirt from air cleaner area. 2. Remove air lter cover ...

  • Echo PB-620ST - page 17

    17 P o w e r B l o w e r o P e r a t o r ' s M a n u a l s p a r k p l u g Level 1. T ools r equired: 19 mm Spark Plug deep socket, feeler gauge Parts Requir ed: REPOWER TM T une Up Kit IMPOR T ANT Use only NGK BPM-8Y spark plug (BPMR-8Y in Canada) other - wise severe engine damage may occur . 1. Remove spark plug, and check for fouling, and w ...

  • Echo PB-620ST - page 18

    18 A B C e x h a u s t s y s t e m Spark Arrestor Screen Level 2. T ools r equired: Cross head screwdriver , soft metal brush Parts Requir ed: Spark arrestor screen, Gaskets (3) IMPOR T ANT Carbon deposits in mufer will cause a drop in engine output and overheating. Spark arrestor screen must be checked periodically . 1. Remove spark plug lead f ...

  • Echo PB-620ST - page 19

    19 P o w e r B l o w e r o P e r a t o r ' s M a n u a l Exhaust Port Cleaning Level 2. T ools r equired: 4 & 5 mm Hexagon wrench, Cross head screwdriver, W ood or plastic scraper Parts Requir ed: As needed: Heat Shield 1. Remove spark plug lead from spark plug, and remove engine or mufer cover (5 screws). 2. Place piston at top dead ce ...

  • Echo PB-620ST - page 20

    20 C a r b u r e t o r a d j u s t m e n t Engine Break-In New engines must be operated for a minimum duration of two tanks of fuel before carburetor adjustments can be made. During the break-in period your engine performance will increase and exhaust emissions will stabilize. Idle speed can be adjusted as required. High Altitude Operation This eng ...

  • Echo PB-620ST - page 21

    21 P o w e r B l o w e r o P e r a t o r ' s M a n u a l Initial Adjustment 1. W ith engine off, turn HI speed screw (C) counterclockwise to stop. 2. T urn LO speed screw (B) midway between stops. 3. T urn idle screw (A) until tip of screw just touches throttle plate; then turn three (3) turns clockwise. Final Adjustment IMPOR T ANT Limiter ca ...

  • Echo PB-620ST - page 22

    22 DANGER Fuel vapors are extremely ammable and may cause re and/or explosion. Never test for ignition spark by ground- ing spark plug near cylinder plug hole, otherwise serious personal injury may result. t r o u b l e s h o o t I n g T R A H C G N I T O O H S E L B U O R T m e l b o r Pk c e h Cs u t a t Se s u a C y d e m e R - s k n a r c ...

  • Echo PB-620ST - page 23

    23 P o w e r B l o w e r o P e r a t o r ' s M a n u a l s t o r a g e W ARNING During operation the mufer or catalytic mufer and surrounding cover become hot. Always keep exhaust area clear of ammable debris during transportation or when storing, otherwise serious property damage or personal injury may result. Long T erm Storage (Ove ...

  • Echo PB-620ST - page 24

    24 MODEL ---------------------------------------------------- PB-620ST Length ------------------------------------------------------ 325 mm (12.8 in.) W idth -------------------------------------------------------- 475 mm (18.7 in.) Height ------------------------------------------------------- 490 mm (19.3 in.) W eight (dry) ---------------------- ...

  • Echo PB-620ST - page 25

    25 P o w e r B l o w e r o P e r a t o r ' s M a n u a l ECHO LIMITED W ARRANTY ST A TEMENT FOR PRODUCT SOLD IN USA AND CANADA BEGINNING 01/01/2010 ECHO'S RESPONSIBILITY ECHO In corporated’s Limited Warranty , provides to the original purchaser that this ECHO product is free from defects in material and workmanship . Under normal use an ...

  • Echo PB-620ST - page 26

    26 PURCHASED REP AIR P ARTS, SHORT BLOCKS AND ACCESSORIES   ...

  • Echo PB-620ST - page 27

    27 P o w e r B l o w e r o P e r a t o r ' s M a n u a l ECHO INCORPORA TED EMISSION CONTROL W ARRANTY ST A TEMENT FOR ECHO AND SHINDAIWA BRANDS The Environmental Protection Agency (EP A) and the California Air Resources Board (C.A.R.B.) and ECHO Incorporated (ECHO Inc.) are pleased to explain the emission control system warranty on your 2010 ...

  • Echo PB-620ST - page 28

    DEALER? Call 1-800-432-ECHO 1-800-432-3246 or www .echo-usa.com ECHO, INCORPORA TED 400 O a k w O O d R O a d L a k e Z u R i c h , iL 60047 www .echo-usa.com CONSUMER PRODUCT SUPPORT 1-800-673-1558 8:30 - 4:30 Mon - Fri C.S.T . P0371 1001001/P0371 1999999 P03812001001/P03812999999 s e r v I C I n g I n f o r m a t I o n p a r t s / s e r I a l n u ...

メーカー Echo カテゴリー Blower

Echo PB-620STのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- PB-620STの取扱説明書
- Echoの製品カード
- パンフレット
- またはEcho PB-620STの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Echo PB-620STの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Echo PB-620STの取り付け説明書、サービスマニュアル、簡易説明書、またはEcho PB-620STのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Echo PB-620STの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Echo PB-620STデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがEcho PB-620STを使用するのを助ける技術的文書のことです。説明書は通常、全てのEcho PB-620STユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Echoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Echo PB-620STの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははEcho PB-620STの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Echo PB-620STに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Echo PB-620STデバイスの基本機能を使うにあたってのヒント。 Echo PB-620STのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Echo PB-620STに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるEcho PB-620STのメーカー/サービスへの連絡先に関する情報。

Echo PB-620STについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもEcho PB-620STの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがEcho PB-620STで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)