    FieldPoint ™ is a trademark of National Instruments Corporation. Product and company names are trademarks or trade names of their respective companies. 321697A-01 © Copyright 1997 National Instruments Corp. All rights reserved. July 1997 FP-1000 FieldPoint RS-232 Network Module Highlights • RS-232 interface to host computer • Built-in isolat ...

  • National Instruments FP-1000 - page 2

    2 DIN Rail Mounting NOTE: Terminal bases must be connected to the network module before applying power to the module. Do not connect or disconnect terminal bases while power is applied to the network module. The FP-1000 has a simple rail clip for mounting reliably onto a standard 35 mm DIN rail. To install the FP-1000 to the DIN rail, follow these ...

  • National Instruments FP-1000 - page 3

    3 4. Add terminal bases to the DIN rail with their local bus connectors firmly mated to the FP-1000 local bus connector. The FP-1000 is shipped with a protective cover over the local bus connector. Remove this protective cover, and place it over the local bus connector of the last terminal base in the stack. Figure 3 shows an installed FP-1000 netw ...

  • National Instruments FP-1000 - page 4

    4 Figure 4. RS-232 Connector Pinout Up to 24 additional FP-1001 network modules can be connected to this FP-1000 module by using the built in RS-485 repeater. This repeater makes the RS-485 port of the FP-1000 appear to the additional FP-1001 modules as if it were an RS-485 port of the host computer. The pinout of the RS-485 connector is shown in F ...

  • National Instruments FP-1000 - page 5

    5 These connections are shown in Figure 6. Figure 6. Typical Signal Connections with One FP-1000 Connected to Multiple FP-1001 Network Modules Figure 6 also shows the use of 120 Ohm termination resistors. An RS-485 network must be terminated at each end of the network, but not anywhere else. Termination resistors should be installed between the RX ...

  • National Instruments FP-1000 - page 6

    6 module is at address 22, and so on. A terminal base is assigned a network address whether an I/O module is inserted into it or not. Figure 7. Address and Baud Rate Switch Table 1 shows the possible switch positions and the corresponding address of the FP-1000. Table 1. Network Address Switch Settings Switch Positions 1-5 Network Module Address (D ...

  • National Instruments FP-1000 - page 7

    7 Switches 6-8 set the baud rate of the FP-1000. Table 2 shows the switch positions and the corresponding network baud rates. 70 200 80 210 90 220 100 230 110 240 120 Other Settings Not Allowed Table 2. Baud Rate Switch Settings Switch Positions 6-8 Network Module Baud Rate Switch Positions 6-8 Network Module Baud Rate 300 19200 1200 38400 2400 576 ...

  • National Instruments FP-1000 - page 8

    8 Powering the FP-1000 NOTE: Terminal bases must be connected to the FP-1000, and the baud rate switch must be set, before power is applied to the FP-1000. An 11-30 VDC power supply is required by each FieldPoint stack. The network module filters and regulates this supplied power and provides power for all the I/O modules in the stack. Therefore yo ...

  • National Instruments FP-1000 - page 9

    9 Specifications Network ports ................................... 1 RS-232 port, 1 RS-485 repeater port Baud Rates ........................................ 300, 1200, 2400, 9600, 19200, 38400, 57600, 115200 (switch selectable) Communication parameters .............. 1 start bit, 8 data bits, 1 stop bit, No parity RS-485 isolation ................. ...

  • National Instruments FP-1000 - page 10

    10 Mechanical Dimensions Figure 9 shows the mechanical dimensions of the FP-1000. Figure 9. Mechanical Dimensions 4.31 [109.5] 3.58 [90.9] 4.19 [106.4] FP1000.fm Page 10 Thursday, July 31, 1997 8:49 AM ...

  • National Instruments FP-1000 - page 11

    FP1000.fm Page 11 Thursday, July 31, 1997 8:49 AM ...

  • National Instruments FP-1000 - page 12

    FP1000.fm Page 12 Thursday, July 31, 1997 8:49 AM ...

メーカー National Instruments カテゴリー Network Router

National Instruments FP-1000のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- FP-1000の取扱説明書
- National Instrumentsの製品カード
- パンフレット
- またはNational Instruments FP-1000の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、National Instruments FP-1000の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、National Instruments FP-1000の取り付け説明書、サービスマニュアル、簡易説明書、またはNational Instruments FP-1000のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、National Instruments FP-1000の製品を使用するにあたって最も人気のある説明書を閲覧できます。

National Instruments FP-1000デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがNational Instruments FP-1000を使用するのを助ける技術的文書のことです。説明書は通常、全てのNational Instruments FP-1000ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

National Instrumentsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. National Instruments FP-1000の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははNational Instruments FP-1000の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。National Instruments FP-1000に関してこのドキュメントで見つけることができる全てのヒントの目次
3. National Instruments FP-1000デバイスの基本機能を使うにあたってのヒント。 National Instruments FP-1000のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。National Instruments FP-1000に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるNational Instruments FP-1000のメーカー/サービスへの連絡先に関する情報。

National Instruments FP-1000についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもNational Instruments FP-1000の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがNational Instruments FP-1000で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)