    Part #MAN080 Rev. 1.0 S F-1128HV/R16-PnP High Performance V .34/V .42bis 28,800 BPS Internal Plug and Play F AX/V oice/Data Modem Featuring Advanced Full- Duplex Speakerphone Functions User's Manual ...

  • MaxTech V.34/V.42bis - page 2

    Contents Section One - Introduction ................................. 1 Section T wo - Installation .................................. 1 Section Three - A T Command Set .................... 7 Section Four - S Registers .............................. 13 Section Five - Result Codes ............................ 15 Section Six - Troubleshooting ....... ...

  • MaxTech V.34/V.42bis - page 3

    1 Section One - Introduction This 28.8 Kbps Plug and Play FAX/Voice/Data Speakerphone Modem connects your computer to all popular high speed modems available today. Your new modem features advanced speakerphone functions for hands-free voice communication and is compatible with Plug and Play (PnP) systems for simplified installation and configurati ...

  • MaxTech V.34/V.42bis - page 4

    2 or, 2. If running DOS or Windows 3.x, configure the modem using the included modem driver. Instructions for installing this driver are included in the text file called README.1ST on the Windows 95 driver disk. The README.1ST file can be viewed by loading it into any wordprocessor or any text editor (i.e. DOS EDIT, NOTEPAD). It may also be viewed ...

  • MaxTech V.34/V.42bis - page 5

    3 6. Replace the computer cover and plug in your com- puter. 7. Connect the telephone cable from the modem's LINE connector to the telephone wall jack. See Figure 2-2. 8. Optionally, connect your telephone to the modem's PHONE connector. 9. Optionally, connect your microphone to the modem's MIC jack. 10. Optionally, connect your spea ...

  • MaxTech V.34/V.42bis - page 6

    4 The Install From Disk dialog box now instructs you to “Insert the manufacturer's installation disk into the drive selected, and then click OK.” Insert the modem's Utility diskette into the disk drive and type A: (or B: if inserted in drive B) in the “Copy manufacturer's files from:” box. Click “OK.” Windows 95 may req ...

  • MaxTech V.34/V.42bis - page 7

    5 MANAGER|MAIN|CONTROL PANEL , click on PORTS and follow Windows 3.1x user's manual instructions on configuring the installed modem COM port. Proceed to Section 2.5, Software Installation/Con- figuration. 2.5 Software Installation and Configuration You are now ready to install and configure the communication software. Refer to your software ma ...

  • MaxTech V.34/V.42bis - page 8

    6 2.7 Testing Your Modem After Installation In order to test your modem you should be familiar with your communication software. Load and set up your communication software and enter into “terminal mode.” Make sure that the COM Port and IRQ settings of the modem match the software. Type AT on your terminal screen and press ENTER . You may see ? ...

  • MaxTech V.34/V.42bis - page 9

    7 Section Three - AT Command Set 3.1 Executing Commands Commands are accepted by the modem while it is in Command Mode. Your modem is automatically in Command Mode until you dial a number and establish a connection. Commands may be sent to your modem from a PC running communication software or any other terminal devices. Your modem is capable of da ...

  • MaxTech V.34/V.42bis - page 10

    8 , pause @ wait for five seconds of silence ! flash ; return to Command Mode after dialing DS=n Dial one of the four telephone numbers (n=0-3) stored in the modem’s non-volatile memory. E_ E0 Commands are not echoed E1 Commands are echoed ++ + Escape Characters - Switch from Data Mode to Command Mode H_ H0 Force modem on-hook (hang up) H1 Force ...

  • MaxTech V.34/V.42bis - page 11

    9 W_ W0 Report DTE speed only W 1 Report line speed, error correction protocol, and DTE speed. W 2 Report DCE speed only X _ X 0 Hayes Smartmodem 300 compatible responses/blind dialing. X1 Same as X0 plus all CONNECT responses/ blind dialing X 2 Same as X1 plus dial tone detection X 3 Same as X1 plus busy detection/blind dialing X4 All responses an ...

  • MaxTech V.34/V.42bis - page 12

    10 ratio &P2 Same as &P0 setting but at 20 pulses per minute &P3 Same as &P1 setting but at 20 pulses per minute &R_ &R 0 Reserved & R 1 CTS operates per flow control requirements &S_ &S 0 Force DSR Signal High (ON) &S1 DSR off in command mode, on in on-line mode &T _ &T0 Ends test in progress &T1 ...

  • MaxTech V.34/V.42bis - page 13

    11 d =300-28800. A, b, c, d default=11, 1, 300, 28800. Parameter “ a ” specifies the modulation protocol desired where: 0=V.21, 1=V.22, 2=V.22bis, 3=V.23, 9=V.32, 10=V.32bis, 11=V.34, 64=Bell 103, 69=Bell 212, and 74=VFC. Parameter “ b ” specifies automode operations where: 0=automode disabled, 1= automode enabled with V.8/V.32 Annex A. Par ...

  • MaxTech V.34/V.42bis - page 14

    12 N2 V.42 or MNP data link only N 3 V.42/MNP/Normal data link N4 V.42 data link only N5 MNP data link only 3.6 Fax Class 1 Commands +FAE=n Data/Fax Auto Answer +FCLASS=n Service Class +FRH=n Receive data with HDLC framing +FRM=n Receive data +FRS=n Receive silence +FTH=n Transmit data with HDLC framing +FTM=n Transmit data +FTS=n Stop transmis ...

  • MaxTech V.34/V.42bis - page 15

    13 +FPTS: Page Transfer Status +FPTS= Page Transfer Status +FREV? Identify Revision +FSPL Enable polling +FTSI: Report the Transmit Station ID 3.8 Voice Commands #BDR Select Baud Rate #CID Enable Caller ID detection and reporting format #CLS Select Data, Fax or Voice/Audio #MDL? Identify Model #MFR? Identify Manufacturer #REV? Identify Revision Lev ...

  • MaxTech V.34/V.42bis - page 16

    14 Table 4-1 S - Registers Register Function Range/units Default S0 Auto-answer Ring 0-255 /rings 0 S1 Ring counter 0-255 /rings 0 S2 Escape code character 0-127 /ASCII 43 S3 Carriage return character 0-127 /ASCII 13 S4 Line feed character 0-127 /ASCII 10 S5 Backspace character 0-32, 127 /ASCII 8 S6 Dial tone wait time 2-255 /seconds 2 S7 Remote ca ...

  • MaxTech V.34/V.42bis - page 17

    15 S49-81 Reserved S82 Break options 3, 7, or 128 128 S83-85 Reserved S86 Connection failure code 0, 4, 5, 9, 12, 13, 14 * S87-S90 Reserved S91 Transmit attenuation 0-15/dBm 10 S92 Fax attenuation 0-15/dBm 10 S95 Extended result code options Bit-mapped register Section Five - Result Codes OK 0 CONNECT 1 RING 2 NO CARRIER 3 ERROR 4 CONNECT 1200 5 NO ...

  • MaxTech V.34/V.42bis - page 18

    16 receive data from the modem. 2. Make sure that your modem is initialized correctly. Your modem may have been initialized to not display re- sponses. You may factory-reset the modem by issuing AT&F and press ENTER . The factory default allows the modem to display responses after a command has been executed. Modem does not dial. 1. Make sure t ...

  • MaxTech V.34/V.42bis - page 19

    17 communication software. 3. Make sure the data speed is not faster than your computer's capability. Most IBM compatibles are ca- pable of 19,200 bps under DOS and Windows. Operat- ing at higher speeds under Windows requires a faster CPU (386/486 or better), a high performance replace- ment Windows 3.1x comm.drv , or Windows 95. Modem experie ...

  • MaxTech V.34/V.42bis - page 20

    18 Data format: 300-115200 bps Power: 0.75 W Temperature: 0 to 55 degrees C (Operating) Caller ID: Y es PnP: Revision 1.0a Speakerphone: Full-duplex with DSP echo cancellation Appendix B - Speaker Type Selection Your modem supports both mono and stereo speakers. Use jumper JP3 to select the speaker type. The modem is factory set to use stereo speak ...

  • MaxTech V.34/V.42bis - page 21

    19 The FCC also requires the transmitter of a FAX transmission be properly identified (per FCC Rules Part 68, Sec. 68.381 (c) (3)). FCC Class B Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protec- tion ...

  • MaxTech V.34/V.42bis - page 22

    20 company cause to request the user to disconnect the equip- ment. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. Caution: Users should ...

  • MaxTech V.34/V.42bis - page 23

    21 ...

メーカー MaxTech カテゴリー Network Card

MaxTech V.34/V.42bisのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- V.34/V.42bisの取扱説明書
- MaxTechの製品カード
- パンフレット
- またはMaxTech V.34/V.42bisの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、MaxTech V.34/V.42bisの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、MaxTech V.34/V.42bisの取り付け説明書、サービスマニュアル、簡易説明書、またはMaxTech V.34/V.42bisのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、MaxTech V.34/V.42bisの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

MaxTech V.34/V.42bisデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMaxTech V.34/V.42bisを使用するのを助ける技術的文書のことです。説明書は通常、全てのMaxTech V.34/V.42bisユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

MaxTechの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. MaxTech V.34/V.42bisの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMaxTech V.34/V.42bisの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。MaxTech V.34/V.42bisに関してこのドキュメントで見つけることができる全てのヒントの目次
3. MaxTech V.34/V.42bisデバイスの基本機能を使うにあたってのヒント。 MaxTech V.34/V.42bisのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。MaxTech V.34/V.42bisに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMaxTech V.34/V.42bisのメーカー/サービスへの連絡先に関する情報。

MaxTech V.34/V.42bisについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMaxTech V.34/V.42bisの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMaxTech V.34/V.42bisで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)