    562156-UIM-A-0610 R-410A OUTDOOR SPLIT -SYSTEM AIR CONDITIONING MODELS: 16 SEER - CZF / AC6B / AL6B SERIES 2 TO 5 T ONS INSTALLATION MANUAL LISTED ISO 9001 Certified Quality Management System T ABLE OF CONTENTS GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 SAFETY . . . . . . . . . . . . . . . . . . . . . . ...

  • Johnson Controls AC6B - page 2

    562156-UIM-A-0610 2 Johnson Controls Unitary Products INSPECTION As soon as a unit is r eceived, it should be inspected for possible dam- age during transit. If damage is evident, th e extent of the damage should be noted on the carrier ’s delivery receipt. A sep arate request for inspection by the carrier ’ s agent sh ould be made in writing. ...

  • Johnson Controls AC6B - page 3

    562156-UIM-A-0610 Johnson Controls Unitary Produ cts 3 GROUND IN ST ALLA TION The unit may be installed at ground level on a solid b ase that will not shift or settle, causing strain on t he refrigerant lines and possible leaks. Maintain the clearances shown in Figure 1 "T ypical Installation with Required Clearances" and install the unit ...

  • Johnson Controls AC6B - page 4

    562156-UIM-A-0610 4 Johnson Controls Unitary Products The outdoor condensing unit must be connected to the indoor evapora - tor coil using field supplied refrigerant grade copper tubing that is inter- nally clean and dry . Units should be installed only with the tubing sizes for approved system combinations as specified in tabular data sheet. The c ...

  • Johnson Controls AC6B - page 5

    562156-UIM-A-0610 Johnson Controls Unitary Produ cts 5 2. Remove the cap and Schrader core from both the liquid and vapor service valve service ports at th e outdoor unit. Connect low pressure nitrogen to the liquid line service port. 3. Braze the liquid line to the liquid valve at the outdoor unit. Be sure to wrap the valve body with a wet rag. Al ...

  • Johnson Controls AC6B - page 6

    562156-UIM-A-0610 6 Johnson Controls Unitary Products FIELD CONNECTIONS POWER WIRING 1. Install the proper size weather proof disconnect switch outdoors and within sight of the unit. 2. Remove the screws at the bottom of the corner cover . Slide corner cover down and remove from unit. See Figure 5 "T ypical Field Wir- ing". 3. Run power w ...

  • Johnson Controls AC6B - page 7

    562156-UIM-A-0610 Johnson Controls Unitary Produ cts 7 CFM SELECTION BOARD SETTINGS For proper system operation the CFM Selection Board jumpers must be set properly . Refer to the T ech Guide for the recommende d air flow settings for each size condensing unit and matchu p. Set the cooling speed per the instruct ions for the air handler or furnace ...

  • Johnson Controls AC6B - page 8

    562156-UIM-A-0610 8 Johnson Controls Unitary Products For additional connection diagrams for a ll UPG equipment refer to “Low V olt age System Wiring” document available online at www . upgnet.com in the Product Catalog Section. FIGURE 10: Thermost at Wiring – Single Stage Air Conditioner (with AC control) – PSC Air Handler 6LQJOH6WDJH? ...

  • Johnson Controls AC6B - page 9

    562156-UIM-A-0610 Johnson Controls Unitary Produ cts 9 FIGURE 1 1: Thermostat Wiring – Single S tage Air Conditioner (with AC control) – VS Air Handler 09 $9 ,'02'(/ 6 -XPSHUPXVWE HVHW WR³*$6(/(&´ < )LUVW6WDJH &RPSUHVVRU : 6HFRQG6WDJH+HD W * )DQ 67+683E 7+(502 67$7 ...

  • Johnson Controls AC6B - page 10

    562156-UIM-A-0610 10 Johnson Controls Unitary Products FIGURE 12: Thermostat Wiring – Single S tage Air Conditi oner (with AC control) – Modulating F urnace </&/& 7 /& 7& </&& ,'02'(/ 6 700 <00 <0/0 -XPSHUPX ...

  • Johnson Controls AC6B - page 11

    562156-UIM-A-0610 Johnson Controls Unitary Produ cts 11 SECTION VI: SY STEM CHARGE 1. The factory charge in the outdoor unit includes enough charge for the unit, a 15 ft. line set and the smallest rated indoor coil match-up. Some indoor coil matches may r equire additional charge. See tabu- lar data sheet provided in unit literature packet for char ...

  • Johnson Controls AC6B - page 12

    562156-UIM-A-0610 12 Johnson Controls Unitary Products 3. If the coil needs to be cleaned , use clean water to wash dust, dir t, and debris from outdoor condensing coil. 4. Refer to the furnace or air handler instructions for filter a nd blower motor maintenance. 5. The indoor coil and drain pan should be inspected and clea ned reg- ularly to preve ...

  • Johnson Controls AC6B - page 13

    562156-UIM-A-0610 Johnson Controls Unitary Produ cts 13 LED DIAGN OSTIC INDICA TORS The control includes two LED’s that display diagnostic information. LED1 is red and LED2 is green. These LED’s are used to display oper- ational mode, fault information. A third LED, LED3 is used to display status information. LED3 is yellow . These LED’s are ...

  • Johnson Controls AC6B - page 14

    562156-UIM-A-0610 14 Johnson Controls Unitary Products F AUL T CODE DISPLA Y The control will display any fault cod e that is currently active using the LED’s. The control will display the fault code, pause two seconds, and display the fault again. The control will continue the fault code display until the condition that caused the f ault code no ...

  • Johnson Controls AC6B - page 15

    562156-UIM-A-0610 Johnson Controls Unitary Produ cts 15 COOLING OPERA TION First-St age Cooling Operation During first-stage cooling operation, the con trol will receive a thermostat signal at the Y1 terminal. The contr ol will energize the M compressor output terminal. This signal energi zes the coil on the compressor con- tactor causing the compr ...

  • Johnson Controls AC6B - page 16

    562156-UIM-A-0610 16 Johnson Controls Unitary Products SECTION IX: WIRING DIAGRAM FIGURE 13: Wiring Diagram (2 - 4 T on) ...

  • Johnson Controls AC6B - page 17

    562156-UIM-A-0610 Johnson Controls Unitary Produ cts 17 FIGURE 14: Wiring Diagram (5 T on) ...

  • Johnson Controls AC6B - page 18

    Subject to change without not ice. Published in U.S.A. 562156-UIM-A-0610 Copyright © 2010 by Johnson Controls, Inc. All rights reserved. Supersedes: Nothing Johnson Contro ls Unitar y Prod uc t s 5005 Y ork Driv e Norman, OK 73069 NOTES ...

メーカー Johnson Controls カテゴリー Air Conditioner

Johnson Controls AC6Bのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AC6Bの取扱説明書
- Johnson Controlsの製品カード
- パンフレット
- またはJohnson Controls AC6Bの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Johnson Controls AC6Bの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Johnson Controls AC6Bの取り付け説明書、サービスマニュアル、簡易説明書、またはJohnson Controls AC6Bのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Johnson Controls AC6Bの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Johnson Controls AC6Bデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがJohnson Controls AC6Bを使用するのを助ける技術的文書のことです。説明書は通常、全てのJohnson Controls AC6Bユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Johnson Controlsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Johnson Controls AC6Bの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははJohnson Controls AC6Bの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Johnson Controls AC6Bに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Johnson Controls AC6Bデバイスの基本機能を使うにあたってのヒント。 Johnson Controls AC6Bのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Johnson Controls AC6Bに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるJohnson Controls AC6Bのメーカー/サービスへの連絡先に関する情報。

Johnson Controls AC6Bについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもJohnson Controls AC6Bの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがJohnson Controls AC6Bで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)