    Instructions – Parts List GRACO INC.ąP .O. BOX 1441ąMINNEAPOLIS, MNą55440-1441 Copyright 1975, Graco Inc. is registered to I.S. EN ISO 9001 307160R Read warnings and instructions. V iscount R II Pump 1500 psi (10.3 MPa, 103 bar) Maximum Hydraulic Input Pressure 1000 psi (7 MPa, 69 bar) Maximum Pump Outlet Pressure Model 210313, Series D With S ...

  • Hitachi 210313 - page 2

    2 307160 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maintenance 10 . . . . . . . . . . . . . . . . . . . . . . ...

  • Hitachi 210313 - page 3

    3 307160 W ARNING INJECTION HAZARD Spray from the gun/valve, leaks or ruptured components can inject fluid into your body and cause ex- tremely serious injury , including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury . D Fluid injected into the skin might look like just a cut, but it is a serious i ...

  • Hitachi 210313 - page 4

    4 307160 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and re- sult in a fire or explosion and serious injury . D Ground the equipment and the object being sprayed. Refer to Grounding on page 5. D If there is any static sparking or you feel an electric shock while usin ...

  • Hitachi 210313 - page 5

    5 307160 Installation General Information NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing. NOTE: Always use Genuine Graco Parts and Acces- sories, available from your Graco distributor . Grounding W ARNING FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system ...

  • Hitachi 210313 - page 6

    6 307160 Installation Mount the pump to suit the type of installation planned. Pump dimensions and mounting hole layout are shown on page 14. CAUTION The hydraulic supply system must be kept clean at all times to avoid damage to the motor and hydraulic power supply . Blow out all hydraulic lines with air and flush thoroughly with compatible solvent ...

  • Hitachi 210313 - page 7

    7 307160 Installation 0627A KEY A B C D E F G H J K L M N P Q R S T Fluid Hose to Gun Fluid Drain V alve Suction Hose Hydraulic Return Line Hydraulic Return Shutoff V alve Pressure Gauge Flow Control V alve Pressure Reducing V alve Accumulator Drain Line (from pressure reducing valve) Hydraulic Supply Line Hydraulic Power Supply Ground Wire W et-Cu ...

  • Hitachi 210313 - page 8

    8 307160 Operation Pressure Relief Procedure W ARNING INJECTION HAZARD Fluid under high pressure can be in- jected through the skin and cause seri- ous injury . T o reduce the risk of an injury from injection, splashing fluid, or moving parts, fol- low the Pressure Relief Procedure whenever you D Are instructed to relieve the pressure D Stop sprayi ...

  • Hitachi 210313 - page 9

    9 307160 Operation W ARNING COMPONENT RUPTURE HAZARD T o reduce the risk of overpressurizing your system, which could cause compo- nent rupture and serious injury , never exceed the specified Maximum Hydraulic Input Pressure to the pump (see the T echnical Data on page 15). T o prevent overpressurizing the hydraulic motor or its seals, always shut ...

  • Hitachi 210313 - page 10

    10 307160 Maintenance Carefully monitor your fluid supply . If your pump us running too fast, or accelerates quickly , it is probably out of fluid. Shut off the hydraulic power supply imme- diately to prevent damage to the pump. If the fluid supply is empty , and air has entered the fluid lines, be sure to prime the pump again before regular operat ...

  • Hitachi 210313 - page 11

    11 307160 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. Before servicing this equipment, always make sure to relieve the pressure. NOTE: Check all possible problems and solutions before disassembling the pump. Problem Cause Solu ...

  • Hitachi 210313 - page 12

    12 307160 Service Fig. 3 06640 1 11 8 7 1 1 12 3 6 5 T 4 9 1 T orque to 40–50 ft-lb (54–68 N S m) NOTE: T o service the displacement pump, refer to manual 308043, supplied. NOTE: T o service the hydraulic motor , refer to manual 308158, supplied. Disassembly (See Fig. 3) W ARNING T o reduce the risk of serious injury whenever you are instructed ...

  • Hitachi 210313 - page 13

    13 307160 Parts 06640 11 8 7 1 1 12 3 6 5 4 9 Ref. No. Part N o. Description Qty . 1 100103 PIN, cott er; 1.5” (38.1 mm) long 2 3 101712 LOCKNUT ; 5/8–1 1; with nylon insert 3 4 101936 NUT , hex, jam; 3/4–10 1 5 158674 O-RING; nitrile rubber 1 6 16791 1 ROD, tie; 7” (177.8 mm) long, shoulder-to-shoulder 3 7 168210 NUT , shouldered 1 8 16821 ...

  • Hitachi 210313 - page 14

    14 307160 Dimensions 06641 48.1” (1220 mm) 23.2” (585 mm) 3/4 npt inlet 1” npt outlet 2” npt fluid inlet 1–1/2” npt fluid outlet Mounting Hole Layout 06595 gasket 161806 four 0.437” (1 1.1 mm) holes on 10.5” (267 mm) bolt circle 45 _ 90 _ 1.38” (34.9 mm) radius 4” (102 mm) 9.75” (247.7 mm) diameter ...

  • Hitachi 210313 - page 15

    15 307160 T echnical Data Maximum hydraulic input pressure 1500 psi (10.3 MPa, 103 bar) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maximum pump outlet pressure 1000 psi (7.0 MPa, 69 bar) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hydraulic fluid cons ...

  • Hitachi 210313 - page 16

    16 307160 Graco Standard W arranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by a n authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for ...

メーカー Hitachi カテゴリー Water Pump

Hitachi 210313のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 210313の取扱説明書
- Hitachiの製品カード
- パンフレット
- またはHitachi 210313の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Hitachi 210313の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Hitachi 210313の取り付け説明書、サービスマニュアル、簡易説明書、またはHitachi 210313のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Hitachi 210313の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Hitachi 210313デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHitachi 210313を使用するのを助ける技術的文書のことです。説明書は通常、全てのHitachi 210313ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Hitachiの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Hitachi 210313の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHitachi 210313の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Hitachi 210313に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Hitachi 210313デバイスの基本機能を使うにあたってのヒント。 Hitachi 210313のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Hitachi 210313に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHitachi 210313のメーカー/サービスへの連絡先に関する情報。

Hitachi 210313についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHitachi 210313の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHitachi 210313で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)