Quartz Thermo installation guide page 1 Quartz ® Thermo C oncealed show er v alv e with adjust able head ...
-
Quartz QZ3111 - page 2
Quartz Thermo installation guide page 2 Show er s ystems Quartz Thermo built-in shower v alv e with adjustable head QZ3111 C omponents ...
-
Quartz QZ3111 - page 3
Quartz Thermo installation guide page 3 Import ant inf ormation Intr oduction The Quartz Thermo is designed f or both built-in and concealed panel mount installation and is supplied complet e with adjustable height head. Quartz Thermo provides close t emperatur e stability and f ail saf e protection when inst alled on approv ed gra vity or pumped s ...
-
Quartz QZ3111 - page 4
Quartz Thermo installation guide page 4 Import ant inf ormation P ump installation UNDER NO CIRCUMST ANCES MUST A PUMP BE FITTED DIRECTL Y T O THE W A TER MAIN. A pump must only be used to boost the pressure f rom t ank-f ed supplies. A typical la yout is shown on the rev erse of this guide. Stored w ater c apacities The minimum capacity of the col ...
-
Quartz QZ3111 - page 5
Quartz Thermo installation guide page 5 Step-b y-step instructions In addition to the guide below it is essential that the written instructions overleaf ar e read and understood and that you hav e all the necessary components (shown overleaf) bef ore commencing installation. F ailure to install the product in accor dance with these instructions may ...
-
Quartz QZ3111 - page 6
Quartz Thermo installation guide page 6 Set the temper ature control lev er to full cold (9 o’clock) prior to removing the f our screws securing the lever to the v alve. C arefully r emove the temper ature lev er to reveal the lilac temper ature preset ov erride ring and the white temper ature preset location ring. Neither of these parts need to ...
-
Quartz QZ3111 - page 7
Quartz Thermo installation guide page 7 The installation may now be check ed f or leaks. T emporarily cap off the outlet supply pipe. Push the on/off lev er assembly onto the f ront of the valve f ully home and turn the knob fully clockwise to ensure the valv e is fully turned off. The on/off shaft is manuf actured with a flat area. The correspondi ...
-
Quartz QZ3111 - page 8
Quartz Thermo installation guide page 8 R efit the lilac temper ature preset ov erride ring and the white temper ature preset location ring if remov ed prior to installation, taking car e to fit the override ring in the correct orientation as outlined in st ep 5. Prior to replacing the shr oud, ensure the shroud seal is in position as indicated. 17 ...
-
Quartz QZ3111 - page 9
Quartz Thermo installation guide page 9 Ensuring the fixing lugs and locating pins are correctly aligned, caref ully place the valve end c ap onto the on/off lever and click into position. 23 Adjustable height head inst allation Prepar e pipe work f rom the shower valv e to the required position f or the hose outlet using a ø15mm copper pipe. Slid ...
-
Quartz QZ3111 - page 10
Quartz Thermo installation guide page 10 Drill and plug two holes 642mm-655mm vertically apart using a spirit le vel if necessary. Fit the rail end clip into position and loosely fit the lower br ack et into position. 7 P ass the rail through the handset holder whilst keeping the slider lev ers depressed with the handset holder pointing in a downwa ...
-
Quartz QZ3111 - page 11
Quartz Thermo installation guide page 11 Connect the hose to the wall outlet assembly after passing it through the gel hook/hose restr aint (if required) and run the shower f or 15 seconds without the handset attached to clear any internal debris, which may be present. 14 ...
-
Quartz QZ3111 - page 12
Quartz Thermo installation guide page 12 After inst allation... Commissioning The Quartz Thermo valve is pr e-set to a saf e maximum show er temper ature. During use, the action of the stop button may be overridden b y depressing it as the temper ature control is r otated. Should it be necessary to r eset the maximum temper ature position please ob ...
-
Quartz QZ3111 - page 13
Quartz Thermo installation guide page 13 User guide Shower oper ation T urn the on/off control fully anti-clockwise into the open position to turn the shower on. N.B. The on/off knob MUST NOT be used as a method of flow control. Rot ate the temper ature contr ol lever, depressing the gr ey temper ature limit button if required, to select a comf ort ...
-
Quartz QZ3111 - page 14
Quartz Thermo installation guide page 14 T roubleshooting guide W ater output is either all hot or all cold, or cold only Symptom P ossible cause Action Re versed inlet supplies Check that the supplies correspond with the inlet markings W ater output is not hot enough The temperatur e of the hot water cylinder is too low W ater flow through the app ...
-
Quartz QZ3111 - page 15
Quartz Thermo installation guide page 15 T ypical inst allations Supply Cent ral heating boiler Supply V ent and draw-off pipe to hot water Underside of cistern Highest point must be below underside of cistern Hot water cylinder Cold f eed to cylinder Connect ‘A’ or ‘B’ B A Supply Hot water cylinder Supply Pressure reducing valve if require ...
-
Quartz QZ3111 - page 16
Aqualisa Pr oducts Limited The Flyer’s W ay W esterham K ent TN16 1DE Sales enquiries: 01959 560010 R epublic of Ireland 01-864-3363 Customer helpline: 01959 560010 R epublic of Ireland 01-844-3212 Brochure Hotline: 0800 652 3669 W ebsite: www.aqualisa.co.uk Email: enquiries@aqualisa.co.uk Please note that calls may be r ecorded f or training and ...
Quartz QZ3111についてご質問がありますか?
次のフォームを使用してください
見つけた説明書を読んでもQuartz QZ3111の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがQuartz QZ3111で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。