Windsor CLP12IAの取扱説明書

23ページ 0.69 mb
ダウンロード

ページに移動 of 23

Summary
  • Windsor CLP12IA - page 1

    Read these instructions before operating the machine Bitte lesen Sie diese Anleitungen, bevor Sie die Maschine in Gebrauch nehmen Operating Instructions (GB/USA) Bedienungsanleitung (GER) 86038280 04/04/07 PRV NO. 98656 AC CARPET EXTRACTOR MOD EL: C O U N T R Y CLP12IA - 10080090 AUSTRALIA CLP12IB - 10080100 BRITIAN CLP12IE - 10080110 EUROPE CLP12I ...

  • Windsor CLP12IA - page 2

    MACHINE DATA LOG 86038280 04/04/07 2ENG YOUR DEALER Name: ____________________ __________________________ __________________________ __________________________ Address: __________________ __________________________ ___________________________________ ________________ Phone Number: _________ _________________________ ______________________________ _ ...

  • Windsor CLP12IA - page 3

    TABLE OF CONTENTS 86038280 04/04/07 3EN G Machine Da ta Log. ............................................... 2 Table of Co ntents ................................................. 3 HOW TO USE THIS MANUAL How to use this Manual. ....................................... 1-1 SAFETY Important Safety Instructions ............................... 2-1 Haza ...

  • Windsor CLP12IA - page 4

    HOW TO USE THIS MANUAL 86038280 04/04/07 1-1ENG This manual contains the f ollowin g sections: - HOW TO USE THIS MANUAL - SAFETY - OPERATIONS - MAINTENANCE - PARTS LIST The HOW TO USE THIS MANUAL section will tell you how to find important information for ordering correct repair parts. Parts may be ordered from authori zed Windsor dealers. When pla ...

  • Windsor CLP12IA - page 5

    86038280 04/04/07 2-1EN G IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use. To reduce the risk of fire, electric shock, or injury: Connect to a properly grounded outlet . Do not leav ...

  • Windsor CLP12IA - page 6

    HAZARD INTENSITY LEVEL 86038280 04/04/07 2-2ENG The following symbols are use d throu ghout this guide as indicated i n their de scriptions: HAZARD INTENSITY LEVEL There are three levels of hazard intensit y identified by signal words - WARNING and CAUTION and FOR SAFETY. The level of hazard intensity is determined by the following definitions: WAR ...

  • Windsor CLP12IA - page 7

    GROUNDING INSTRUCTIONS 86038280 04/04/07 2-3EN G THIS PRODUCT IS FOR COMM E RCIAL USE ONLY. ELECTRICAL: The amp, hertz, and voltage are listed on the data label found on each machine. Using voltages a bove or below those indicated on the data label will cause serious dama ge to the motors. EXTENSION CORDS: If an extension cord is used, the wire siz ...

  • Windsor CLP12IA - page 8

    TECHNICAL SPECIFICATIONS 86038280 04/04/07 3-1EN G ITEM DIMENSION/CAPACITY Electrical 230-240V, 7A, 50 HZ Electric Vacuum Motor (1) 3 stage, 1 hp, 99 cfm (2.80 cubic m/ min.) Waterlift 117” (297cm) Brush (1) 18” (45.7cm.) Brush Speed 1000 rpm Solution Pump 100 PSI, diaphragm style, internal bypass Solution Capacity 12 gallons (45.5l) Solution S ...

  • Windsor CLP12IA - page 9

    CONTROLS/COMPONENT LOCATIONS 86038280 04/04/07 3-2EN G 1. Main Handle. Used to pull and maneuver machine. 2. Handle Adjustment. Used to adjust height of handle, and allow machine to be use d in “PUSH” or “PULL orientation. 3. Electrical Cord. 4. Solution Switch. Turns on pump. Continuou s position (bottom) activates electro-valve to dispense ...

  • Windsor CLP12IA - page 10

    CONTROLS/COMPONENT LOCATIONS 86038280 04/04/07 3-3EN G 1 2 3 13 12 6 9 8 1. Solution Accessory Tool Hookup. Used for various auxiliary cleaning t ools. 2. Vacuum Hose Door. Used to connect various auxiliary 1 ½ inch cleaning tool vacuum hoses. 3. Brush Height Adjustment. Used to regulate brush height from storage position to various carpet heights ...

  • Windsor CLP12IA - page 11

    CONTROLS/COMPONENT LOCATIONS 86038280 04/04/07 3-4EN G 1. Solution Intake Cover. 2. Vacuum Intake Cover. 3. Float Shut-Off. 4. Clean-Out Opening. 5. Pour Spout. 6. Lift Handle. 2 1 3 4 5 6 6 ...

  • Windsor CLP12IA - page 12

    OPERATIONS 86038280 04/04/07 3-5ENG Remove electrical co rd an d literature from recovery tank. Fill solution tank (see filling instructions ). Adjust brush to proper setting. Note: For good operation the brush must skim the carpet. If circuit breaker trips raise brush to p revent damage to m otor or ca rpet. Plug cord into grounded ou t let. Note: ...

  • Windsor CLP12IA - page 13

    OPERATIONS 86038280 04/04/07 3-6EN G Select contin uou s setting to st art solution spray or select intermittent setting to enable use of trigger switches to sta rt solution spra y. The intermittent setting requires the operator to hold any one of the three trigger switches in the “on” positio n with the fingers, and is typically used in small ...

  • Windsor CLP12IA - page 14

    FILLING OPERATIONS 86038280 04/04/07 3-7EN G FILLING THE CLIPPER NOTE: Use clean bucket of water to fill solution tank Do not put defoamer, solvents, spotter or prespray chemicals in the solution tank . Do not allow water to spill into vacuum motor inlet. Dry spillage from top of solution tank before replacing recovery tank . CHEMICALS Suitable Che ...

  • Windsor CLP12IA - page 15

    CLEANING PROCEDURE 86038280 04/04/07 3-8EN G Release intermittent trigger switches or turn off continuous setting on solution switch approximately 1 foot before en ding cleaning pass. Push down on handle to raise vacuum shoe and brush before moving to the next cleaning pass. Overlap brush contact area a minimum of 1inch on the right (close cleaning ...

  • Windsor CLP12IA - page 16

    CLEANING PROCEDURE 86038280 04/04/07 3-9EN G STEP 5 STEP 6 After cleaning, turn off all controls, return brush to storage position and ca refully unplug machine. STEP 4 STEP 1 Use right side of machine for cle anin g against walls. SOLUTION INTAKE COVER VACUUM INTAKE COVER O R Start at wall closest to power outlet. For large areas flip handle and o ...

  • Windsor CLP12IA - page 17

    CLEANING PROCEDURE 86038280 04/04/07 3-10EN G To speed drying, use a Windblo wer ™ fan. Empty recovery tank by releasing dump hose. Use a hose with cold water to clean out the recovery tank. Also drain solution tank after each use. STEP 7 STEP 8 RECOVERY DRAIN SOLUTION DRAIN ...

  • Windsor CLP12IA - page 18

    ACCESSORY TOOL USAGE 86038280 04/04/07 3-11ENG Turn on vacuum motor swit ch and set solution switch to intermittent position. Note: Be sure brush switch is in off position and brush is in storage position. Squeeze handle on accessory tool to begin cleaning. STEP 3 STEP 4 STEP 1 STEP 2 Use only one of the following acceptable accessory tools. 860000 ...

  • Windsor CLP12IA - page 19

    MAINTENANCE 86038280 04/04/07 4-1ENG ONLY QUALIFIED MAINTENANCE PE RSONNEL ARE TO PERFORM THE FOLLOWING REPAIRS. VACUUM MOTOR REPLACEME NT 1. Turn off all switches and unplug machi ne. 2. Remove recovery tank. 3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame. 4. Locate the vac ...

  • Windsor CLP12IA - page 20

    MAINTENANCE 86038280 04/04/07 4-2ENG SOLUTION PUMP REPLACEMENT 1. Turn off all switches and unplug the machin e. 2. Remove recovery tank. 3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame. 4. Remove solution hoses from fittings in pump. 5. Remove the (2) screws that fasten the ...

  • Windsor CLP12IA - page 21

    MAINTENANCE 86038280 04/04/07 4-3EN G PERIODIC MAIN TENANCE Twice a month, flush a white vinegar sol ution (One quart vinegar to two gallons of water) or anti- browning solution (mixed as directe d) t hrough the extractor. This will prev ent build-up of alkaline residue in the system. If spray jets become clog ged, remove the spray tips, wash them ...

  • Windsor CLP12IA - page 22

    TROUBLESHOOTING CHART 86038280 04/04/07 4-4ENG PROBLEM CAUSE SOLUTION No Power, Nothing Runs 1. Is the cord plugged in? 2. Circuit breaker tripped in building. 3. Faulty switch. 4. Faulty power cord or pigtail. 1. Plug in cord. 2. Reset breake r 3. Call for service. 4. Call for service. Vacuum Motor Will Not Run 1. Vacuum circuit breaker tripped. 2 ...

  • Windsor CLP12IA - page 23

    NOTES 86038280 04/04/07 4-5EN G ...

メーカー Windsor カテゴリー Carpet Cleaner

Windsor CLP12IAのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CLP12IAの取扱説明書
- Windsorの製品カード
- パンフレット
- またはWindsor CLP12IAの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Windsor CLP12IAの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Windsor CLP12IAの取り付け説明書、サービスマニュアル、簡易説明書、またはWindsor CLP12IAのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Windsor CLP12IAの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Windsor CLP12IAデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがWindsor CLP12IAを使用するのを助ける技術的文書のことです。説明書は通常、全てのWindsor CLP12IAユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Windsorの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Windsor CLP12IAの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははWindsor CLP12IAの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Windsor CLP12IAに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Windsor CLP12IAデバイスの基本機能を使うにあたってのヒント。 Windsor CLP12IAのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Windsor CLP12IAに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるWindsor CLP12IAのメーカー/サービスへの連絡先に関する情報。

Windsor CLP12IAについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもWindsor CLP12IAの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがWindsor CLP12IAで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)