    1:1 RA TIO TRIT ON R 308 Diaphragm Pump Used to pump waterborne and solvent–based paints and catalysts. For professional use only . 1 15 psi (0.8 MPa, 8 bar) Maximum Fluid Working Pressure 1 15 psi (0.8 MPa, 8 bar) Maximum Air Input Pressure Part No. 233500 Aluminum Pump, Series D, npt threads Part No. 233501 Stainless Steel Pump, Series C, npt t ...

  • Graco 233776 - page 2

    2 309303 T able of Contents Safety W arnings 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 1 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maintenance 12 . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Graco 233776 - page 3

    309303 3 W ARNING INSTRUCTIONS EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result in a serious injury .  This equipment is for professional use only .  Read all instruction manuals, tags, and labels before operating the equipment.  Use the equipment only for its intend ...

  • Graco 233776 - page 4

    4 309303 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor air ventilation, open flames, or sparks can cause a hazardous condition and result in fire or explosion and serious injury .  Ground the equipment. Refer to Grounding on page 7.  If there is any static sparking or you feel an electric shock while using this equipment, stop p ...

  • Graco 233776 - page 5

    309303 5 W ARNING PRESSURIZED FLUID HAZARD Spray from the gun, hose leaks, or ruptured components can splash fluid in the eyes or on the skin and cause serious injury .  Do not stop or deflect fluid leaks with your hand, glove, or rag.  Follow the Pressure Relief Procedure on page 1 1 before cleaning, checking, or servicing the equipment.  ...

  • Graco 233776 - page 6

    6 309303 Installation General Information  Fig. 2 shows a wall mounted HVLP spray applica- tion. It is only a guide for selecting and installing system components. Contact your Graco distributor for assistance in planning a system to suit your needs.  Always use Genuine Graco Parts and Accessories, available from your Graco distributor . If y ...

  • Graco 233776 - page 7

    309303 7 Installation Grounding W ARNING FIRE AND EXPLOSION HAZARD This pump must be grounded. Before operating the pump, ground the system as explained below . Also read the sec- tion FIRE AND EXPLOSION HAZARD on page 4. T o reduce the risk of static sparking, ground the pump and all other equipment used or located in the pumping area. Check your ...

  • Graco 233776 - page 8

    8 309303 Installation Air Line W ARNING A bleed-type master air valve (B) is required in your system to relieve air trapped between this valve and the pump. See Fig. 2. T rapped air can cause the pump to cycle unexpectedly , which could result in serious injury , including splashing in the eyes or on the skin, injury from moving parts, or contamina ...

  • Graco 233776 - page 9

    309303 9 Installation KEY A TRI T O N 308 Pump B Bleed-type master air valve (required for pump) C Air supply line D Air line filter E Air line shutof f valve F Pump air regulator G Gun air regulator (used in spray system only) H Fluid pressure regulator (used in spray system only) J Drain/circulation valve K Drain tube L Suction tube M Pump fluid ...

  • Graco 233776 - page 10

    10 309303 Installation Fluid Suction Line  Screw the suction line (L) into the pump inlet (M) snugly . Use a compatible liquid thread sealant on connections to prevent air from getting into the fluid line.  Do not pressure feed this pump.  See the T echnical Data on page 24 for maximum suction lift.  Use an agitator (U) to prevent fluid ...

  • Graco 233776 - page 11

    309303 1 1 Operation Pressure Relief Procedure W ARNING The system remains pressurized until pressure is manually relieved. T o reduce the risk of serious injury from pressurized fluid, accidental spray from the gun, or splashing of any fluid, follow this proce- dure whenever you  Stop spraying  Are instructed to relieve pressure  Check or ...

  • Graco 233776 - page 12

    12 309303 Maintenance Tightening Threaded Connections Before each use, check all hoses for wear or damage. Replace as necessary . Check that all threaded con- nections are tight and leak-free. NOTE: Periodically , re–torque fluid cover screws (38) to 10 ft–lb (13.6 N  m). Cleaning Clean the outside of the equipment daily , using a soft cloth ...

  • Graco 233776 - page 13

    309303 13 T roubleshooting PROBLEM CAUSE SOLUTION Pump runs sluggishly . Worn or damaged carriage o-rings. Service air valve. See page 18. Pump runs erratically . Clogged suction line or inlet strainer . Clear . Sticking or leaking ball check valves. Disassemble and clean ball checks. Replace worn parts. See page 16. Pump runs too fast. Exhausted f ...

  • Graco 233776 - page 14

    14 309303 Service Remove the Fluid and Side Covers T ools Required  T orque wrench  2.5 mm allen wrench  6 mm allen wrench  Adjustable wrench Disassembly W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 1 1. 1. Relieve the pressure. 2. Dis ...

  • Graco 233776 - page 15

    309303 15 Service Remove the Fluid and Side Covers (continued) Reassembly 1. Clean all parts and inspect for wear or damage. Replace parts as needed. 2. If necessary , reinstall the felt dampener (29) and side cover (31). T orque the screws (39) to 28 in-lb (3.1 N  m). 3. Install new ball check seals (24). 4. Place the fluid covers (32) on the h ...

  • Graco 233776 - page 16

    16 309303 Service Ball Check Repair T ools Required  O-ring pick Disassembly NOTE: Ball Check Repair Kit 245067 is available. Parts included in the kit are marked with a double dagger , for example (21  ). Use all the parts in the kit for the best results. 1. Remove the fluid covers. See page 14. 2. Remove the inlet and outlet ball checks. No ...

  • Graco 233776 - page 17

    309303 17 Service Diaphragm Repair T ools Required  M8 bolt  M8 hexnut  Adjustable wrench, or vise NOTE: Diaphragm Repair Kit 245065 is available. Parts included in the kit are marked with an asterisk, for example (6*). Always replace both diaphragms for the best results. 1. Remove the fluid covers. See page 14. W ARNING Wear gloves when r ...

  • Graco 233776 - page 18

    18 309303 Service Air V alve Repair T ools Required  3 mm allen wrench  Needlenose pliers  Retaining ring removal tool  O-ring pick Disassembly NOTE: Air V alve Repair Kit 245066 is available. Parts included in the kit are marked with a dagger , for exam- ple (8  ). Use all the parts in the kit for the best results. 1. Remove the sid ...

  • Graco 233776 - page 19

    309303 19 Service Air V alve Repair (continued) Reassembly 1. Lubricate the o-rings (8  ) and install them on the carriage (7). Slide the carriage into the center housing (1) so the notch faces out, as shown in Fig. 7. 2. Lubricate each o-ring (10  ) and install them on the plugs (9). Insert a plug in each side to secure the carriage (7). Ins ...

  • Graco 233776 - page 20

    20 309303 Service Shaft Repair T ools Required  Needlenose pliers  O-ring pick  Retaining ring removal tool  Vise with soft jaws Disassembly NOTE: Shaft Repair Kit 24A155 is available. Parts included in the kit are marked with a star , for example (5  ). Use all the parts in the kit for the best results. NOTE: Shaft and Bearing Repai ...

  • Graco 233776 - page 21

    309303 21 Service Shaft Repair (continued) ti1035E Fig. 8 38 1 3 2 10 ft-lb (13.6 N  m). Lubricate. Align. 4 1 3 4 1 2 2 2 2 3 3 28 in-lb (3.1 N  m). 4  8  10 12  13 14  15  16   24 24   24 24  32 38 11 9 1 32 17 29 31 39 7 2  8 36 3 4   5 6 6 2 5 Align. See Fig. 6. 5 43  46 45  44 ? ...

  • Graco 233776 - page 22

    22 309303 Parts Part No. 233500 Aluminum Pump, Series D, npt threads Part No. 233501 Stainless Steel Pump, Series C, npt threads (Shown) Part No. 233776 Aluminum Pump, Series C, BSPP threads Part No. 233777 Stainless Steel Pump, Series C, BSPP threads 1 3 4  5  *6 6* 7  8 9  10 11 12  13  14  15  16  17 18 ...

  • Graco 233776 - page 23

    309303 23 Parts NOTE: Purchase items 36–39 locally . Ref. No. Part No. Description Qty . Ref. No. Part No. Description Qty . 1 15J732 HOUSING, center; for Part No. 233500; aluminum 1 198894 HOUSING, center; for Part No. 233501; stainless steel 1 198892 HOUSING, center; for Part No. 233776; aluminum 1 197679 HOUSING, center; for Part No. 233777; s ...

  • Graco 233776 - page 24

    24 309303 T echnical Data Category Data Maximum fluid working pressure 1 15 psi (0.8 MPa, 8.0 bar) Air pressure operating range 12 to 1 15 psi (.08 to 0.8 MPa, 0.8 to 8.0 bar) Ratio 1:1 Maximum free flow delivery 8.5 gal./min (32 l/min) Operating fluid temperature range 50 to 176  C (10 to 80  C) Maximum suction lift 16 ft (4.8 m) dry; 22 ft ...

  • Graco 233776 - page 25

    309303 25 Dimensions BOTTOM VIEW SIDE VIEW Aluminum T wo 0.35 in. (9 mm) diameter holes, for mounting pump 4.1 in. (104 mm) 4.53 in. (1 15 mm) 3/8 npt or 3/8 BSPP Fluid Outlet 3/4 npt or M26 x 1.5 Fluid Inlet 1/4 npt or 1/4 BSPP Air Inlet 4.88 in. (124 mm) 8.2 in. (208 mm) ti1037a TI3265A SIDE VIEW SST 9.1 in. (231.5 mm) ...

  • Graco 233776 - page 26

    26 309303 Graco Standard W arranty Graco w arrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco w ill, for a period of twelve months from th ...

メーカー Graco カテゴリー Heat Pump

Graco 233776のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 233776の取扱説明書
- Gracoの製品カード
- パンフレット
- またはGraco 233776の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Graco 233776の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Graco 233776の取り付け説明書、サービスマニュアル、簡易説明書、またはGraco 233776のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Graco 233776の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Graco 233776デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGraco 233776を使用するのを助ける技術的文書のことです。説明書は通常、全てのGraco 233776ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Gracoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Graco 233776の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGraco 233776の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Graco 233776に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Graco 233776デバイスの基本機能を使うにあたってのヒント。 Graco 233776のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Graco 233776に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGraco 233776のメーカー/サービスへの連絡先に関する情報。

Graco 233776についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGraco 233776の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGraco 233776で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)