Venmar HRV 2600*の取扱説明書

22ページ 4.25 mb
ダウンロード

ページに移動 of 22

Summary
  • Venmar HRV 2600* - page 1

    INST ALLA TION INSTR UCTIONS AND USER MANU AL RESIDENTIAL USE ONL Y INST ALLER: LEA VE THIS MANU AL WITH THE HOMEO WNER. HOMEO WNER: USE AND CARE INFORMA TION ON P AGES 18 T O 21. READ AND SA VE THESE INSTR UCTIONS 04313 re v . G MODELS ...

  • Venmar HRV 2600* - page 2

    ABOUT THIS MANU AL First, we want to cong ratulate you on y our purchase of this excellent unit which will allo w you and y our family to enjo y clean and health y air throughout your home f or years to come! Because of the large amount of models cov ered by this pub lication, the illustrations are typical ones. Some details of your unit ma y be sl ...

  • Venmar HRV 2600* - page 3

    1. T YPICAL I NST ALLA TIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-6 1.1 HR V 2600, HR 2.6, HEP A 3100, HF 3.1 AND HEP A 4100 U NIT I NST ALLA TIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.1.1 S TA N D A LONE . . . . . . . . . . . . . . . . . . . . . . . ...

  • Venmar HRV 2600* - page 4

    1. TYPICAL INST ALLA TIONS Installations ma y vary according to the model number and the position in which the unit is installed. Use the f ollowing illustr ations as guidelines to help you decide on ho w your unit will be installed. All the units should be hung from the joists, and installed either v er tically or horizontally . NO TE: F or more d ...

  • Venmar HRV 2600* - page 5

    1. TYPICAL INST ALLA TIONS (CONT’D) ...

  • Venmar HRV 2600* - page 6

    All 3 types of installations can be used in the attic (Stand Alone, Central Dr aw P oint or Retur n-Retur n). The example sho wn bel ow i s a Return-Retur n installation (connection to a forced air system). VH0051 - 6 - A por tion of stale air is exhausted to the outside and the rest is dr awn to the unit. Outside fresh air is blended with interior ...

  • Venmar HRV 2600* - page 7

    - 7 - 2.3 M OUNTING AND S ER VICING C ONSIDERA TIONS • The two f ollowing pictures are showing the minim um clearance needed to open the door completely . 22.5” 15.75” (572 mm) (400 mm) VD0117 VD0116 22” (559 mm) NO TE: A minimum of 8” (203 mm) clearance from an y obstruction on top of the unit is required for the ductwork radius turn. 8? ...

  • Venmar HRV 2600* - page 8

    - 8 - 3.3 L OCA TING THE U NIT Choose an appropriate location for the unit. • Within an area of the house where the ambient temperature is between 10°C (50°F) and 65°C (149°F) (basement, furnace room, closet, etc.). • So as to provide easy access to the interior of the unit, f or filter maintenance. • Close to an e xter ior wall, so as to ...

  • Venmar HRV 2600* - page 9

    - 9 - 1. Route the cable from the unit to a con venient location f or the wall control. 2. Loosen the locking scre w (the screw cannot be completely remo ved). 3. Detach the f aceplate from the mounting plate by pulling the bottom par t. If necessar y , bore the mounting holes and inser t anchors. 4. P ass the cable (4 wires) through the opening of ...

  • Venmar HRV 2600* - page 10

    7. T urn the unit switch knob to OFF position in order to unloc k the door. Unlatch the door and open it. If required, the door can be removed. T o do so , remov e the stopper ( A ) located on the right side of the door hinge. Then, hold the door and hit with your palm its left side . Slide the door to the right to disengage it from the unit. 8. Us ...

  • Venmar HRV 2600* - page 11

    5.2 H OW TO H ANG THE U NIT Use the 4 chains and springs in the hardware pack pro vided with the unit. According to your needs , you can install the unit either in vertical or hor izontal position. VD0074 ...

  • Venmar HRV 2600* - page 12

    - 12 - 5.3 P LANNING OF THE D UCTWORK All units in this manual are prebalanced. • K eep it simple. Plan for a minimum of bends and joints . • K eep the length of outside insulated duct to a minimum. • Do not v entilate cra wl spaces or cold rooms. Do not attempt to recover the e x haust air from a dryer or a range hood. This w oul d cause clo ...

  • Venmar HRV 2600* - page 13

    5.4 I NST ALLING N ON -I NSULA TED D UCTS AND R EGISTERS ( CONT ’ D ) 5.4.1 S TA N D A LONE S YSTEM ( AS ILLUSTRA TED IN S ECTION 1.1.1) ( CONT ’ D ) A LL UNITS How to connect the fle xible duct to the unit ports • Using the colored stic ker dot included, identify which duct it is (red dot f or stale airflow and b lue dot for filtered airflo ...

  • Venmar HRV 2600* - page 14

    5.4 I NST ALLING N ON -I NSULA TED D UCTS AND R EGISTERS ( CONT ’ D ) 5.4.2 C ENTRAL DRA W P OINT ( AS ILLUSTRA TED IN S ECTION 1.1.2) ( CONT ’ D ) Fresh/Filtered air ductwork (Return side connection) (cont’ d) HEP A 3100, HF 3.1 AND HEP A 4100 UNITS ONL Y ( CONT ’ D ) • Fix the duct connector to the f orced air unit duct using its 4 reta ...

  • Venmar HRV 2600* - page 15

    5.5 I NST ALLING I NSULA TED F LEXIBLE D UCTS Use the f ollowing procedure f or connecting the insulated flexib le ducts to the T andem® transition* ( EXHA UST AIR TO OUTSIDE and FRESH AIR FROM OUTSIDE ). NO TE: If the joist are perpendicular to the ducts, or if the connection to the exterior hood is in a limited area, your installation will need ...

  • Venmar HRV 2600* - page 16

    5.5 I NST ALLING I NSULA TED F LEXIBLE D UCTS ( CONT ’ D ) 5.5.2 C ONNECTION TO THE 5’ ’ TO 6’ ’ O V AL PORTS OF THE UNIT ( CONT ’ D ) 4. Apply duct tape gently to the joint in order to make an airtight seal. 5. Repeat steps 1 to 4 f or the other 5’ ’ to 6’ ’ por t. See figure beside to find the EXHA UST AIR T O OUTSIDE ( 1 ) an ...

  • Venmar HRV 2600* - page 17

    5.6 I NST ALLING D UA L E XTERIOR H OOD ( CONT ’ D ) 5.6.3 C ONNECTING T ANDEM ® TRANSITION TO EXTERIOR D UAL H OOD ( CONT ’ D ) 2. Join the end of the T andem transition to the rear of the e xter ior backplate. Secure with 2 Xmas tree pins and seal properly with duct tape. 3. Lean the e xter ior bac kplate to the exterior wall. Using 4 #8 x 1 ...

  • Venmar HRV 2600* - page 18

    6.1 M AIN S WITCH All units are equipped with a 3-position main s witch, located on the front panel. 6.2 40415 AND 40425 W ALL C ONTR OLS D ESCRIPTION The included wall control is 40415 (intented f or HR V 2600, HEP A 3100 and HEP A 4100 units only) or 40425 control (intented for HR 2.6 and HF 3.1 units only). The w all control is in OFF mode when ...

  • Venmar HRV 2600* - page 19

    6.4 W ALL C ONTROLS C ONFIGURA TION See the configuration tab le below f or the list of configuration parameters. Press the Menu b utton for 3 seconds to enter or e xit the configuration menu. NO TE: The wall control automatically sav es any changes and e xits the configuration menu if no b utton is pressed within the ne xt 60 seconds. Press the Me ...

  • Venmar HRV 2600* - page 20

    - 20 - 7. MAINTENANCE W ARNING Risk of electrical shocks. Before performing an y maintenance or servicing, al ways disconnect the unit fr om its power source. ! 7.1 B IANNU AL M AINTENANCE ( ESSENTIAL ) P erf or m this maintenance when the Filter Maintenance LED is flashing . F ollow these steps: 1. T urn switch knob to OFF to unloc k the door . 2. ...

  • Venmar HRV 2600* - page 21

    - 21 - 7.1 B IANNU AL M AINTENANCE ( ESSENTIAL ) ( CONT ’ D ) 6. W ash the 2 core filters under hot water with mild soap . Rinse thoroughly and let dr y completely bef ore reinstalling on the core. Remove the dust on the core using a v acuum cleaner with a soft brush attachment. 1) Core filters 2) Core NO TE: Make sure the damper spring ( 1 ) is ...

  • Venmar HRV 2600* - page 22

    If the problem is still not solv ed, call your installer or the nearest authorized Service Center . Also , you can reach the Customer Service Depar tment at one of the following telephone n umbers: Exclusively f or models HRV 2600, HEP A 3100 and HEP A 4100: Exclusively f or models HR 2.6 and HF 3.1: 1-800-567-3855. 1-866-737-7770. PROBLEMS SOLUTIO ...

メーカー Venmar カテゴリー Ventilation Hood

Venmar HRV 2600*のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- HRV 2600*の取扱説明書
- Venmarの製品カード
- パンフレット
- またはVenmar HRV 2600*の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Venmar HRV 2600*の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Venmar HRV 2600*の取り付け説明書、サービスマニュアル、簡易説明書、またはVenmar HRV 2600*のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Venmar HRV 2600*の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Venmar HRV 2600*デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがVenmar HRV 2600*を使用するのを助ける技術的文書のことです。説明書は通常、全てのVenmar HRV 2600*ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Venmarの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Venmar HRV 2600*の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははVenmar HRV 2600*の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Venmar HRV 2600*に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Venmar HRV 2600*デバイスの基本機能を使うにあたってのヒント。 Venmar HRV 2600*のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Venmar HRV 2600*に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるVenmar HRV 2600*のメーカー/サービスへの連絡先に関する情報。

Venmar HRV 2600*についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもVenmar HRV 2600*の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがVenmar HRV 2600*で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)