    TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER SM940046 SPW-UMR94EXH56 854.0.2264 SPW-UMR224EXH56 854.0.2267 0.8180.439.0 June 2005 SPW-UMR124EXH56 SPW-UMR164EXH56 SPW-UMR184EXH56 854.0.2266 Model No. Product Code No. SPW-UMR74EXH56 854.0.2301 854.0.2263 854.0.2265 ...

  • Sanyo SPW-UMR164EXH56 - page 2

    IMPORT ANT! Please read before installation This air conditioning system meets strict safety and operating standards. For the installer or service person, it is important to install or service the system so that it operates safely and efficiently . For safe installation and trouble-free operation, you must: • Carefully read this instruction bookl ...

  • Sanyo SPW-UMR164EXH56 - page 3

    Page 1. SPECIFICATIONS 4 1-1 Unit specifications 4 1-2 Major Component specifications 7 1-3 Other Component specifications 10 2. DIMENSIONAL DATA 11 3. ELECTRICAL DATA 13 3-1 Electric Wiring Diagram 13 3-2 Control PCB switches and functions 14 4. FUNCTION 15 4-1 Room Temperature Control 15 4-2 Automatic control for heating and cooling 16 5. REPLACI ...

  • Sanyo SPW-UMR164EXH56 - page 4

    1. SPECIFICATIONS 1-1 Unit Specifications SPW-UMR74/94/124EXH56 Power source V olta g e ratin g Performance Capacity Air circulation (High/Med./Low) m³/h Features Controls/Temperature controls Remote Controller (Option) wired wireless Fan speed Air Filter Sound pressure level (*) high/med/low dB(A) Refrigerant tubing connections Refrigerant Narrow ...

  • Sanyo SPW-UMR164EXH56 - page 5

    SPW-UMR164/184EXH56 Power source V olta g e ratin g Performance Capacity Air circulation (High/Med./Low) m³/h Features Controls/Temperature controls Remote Controller (Option) wired wireless Fan speed Air Filter Sound pressure level (*) high/med/low dB(A) Refrigerant tubing connections Refrigerant Narrow tube mm(in.) tube diameter Wide tube mm(in. ...

  • Sanyo SPW-UMR164EXH56 - page 6

    SPW-UMR224EXH56 Power source V olta g e ratin g Performance Capacity Air circulation (High/Med./Low) m³/h Features Controls/Temperature controls Remote Controller (Option) wired wireless Fan speed Air Filter Sound pressure level (*) high/med/low dB(A) Refrigerant tubing connections Refrigerant Narrow tube mm(in.) tube diameter Wide tube mm(in.) Re ...

  • Sanyo SPW-UMR164EXH56 - page 7

    1-2 Major Component Specifications SPW-XMR74/94/124EXH56 Controller PCB Part No. Controls Fan & Fan Motor Type Q'ty ……. Dia. and lenght mm Fan motor model…Q'ty No. Of poles…rpm (230 V, High) Running Amps A Power input W Coil resistance (Ambient temp. 20 °C ) Ω BLU-BRN: 95 BRN-BLK: 37 BLK-GRY: 15 GRY-VLT: 15 WLT-RED: 30 RED- ...

  • Sanyo SPW-UMR164EXH56 - page 8

    SPW-XMR164/184EXH56 Controller PCB Part No. Controls Fan & Fan Motor Type Q'ty ……. Dia. and lenght mm Fan motor model…Q'ty No. Of poles…rpm (230 V, High) Running Amps A Power input W Coil resistance (Ambient temp. 20 °C ) Ω BLU-BRN: 68 BRN-BLK: 9 BLK-GRY: 36 GRY-VLT: 18 VLT-RED: 18 BRN-YEL: 105 Safety devices Type Operating ...

  • Sanyo SPW-UMR164EXH56 - page 9

    SPW-XMR224EXH56 Controller PCB Part No. Controls Fan & Fan Motor Type Q'ty ……. Dia. and lenght mm Fan motor model…Q'ty No. Of poles…rpm (230 V, High) Running Amps A Power input W Coil resistance (Ambient temp. 20 °C ) Ω BLU-BRN: 68 BRN-BLK: 9 BLK-GRY: 36 GRY-VLT: 18 VLT-RED: 18 BRN-YEL: 105 Safety devices Type Operating tem ...

  • Sanyo SPW-UMR164EXH56 - page 10

    1-3 Other Component Specifications Trasformer Rating Primary Secondary 1 Secondary 2 Secondary 3 Thermal cut-off temp. Thermistor ( Coil sensor E1, E2 ) Resistance k Ω Thermistor ( Coil sensor E3 ) Resistance k Ω Thermistor ( Room sensor TA, TF/BL ) Resistance k Ω Drain pump Model Rating Voltage Input Flow rate Safet y float switch Model Cont ...

  • Sanyo SPW-UMR164EXH56 - page 11

    2. DIMENSIONAL DATA SPW-UMR74/94/124EXH56 11 ...

  • Sanyo SPW-UMR164EXH56 - page 12

    SPW-UMR164/184/224EXH56 12 ...

  • Sanyo SPW-UMR164EXH56 - page 13

    3. ELECTRICAL DATA 3-1 Electric Wiring Diagram 7P terminal board 1(L) 2(N) U1 U2 R1 R2 w i r i ng remote con t ro ll e r power supp ly inter-unit con t ro l 13 ...

  • Sanyo SPW-UMR164EXH56 - page 14

    3-2 Control PCB switches and functions CR-TRP50A-B OC (CN040) EMG (CN044) VARISTOR (VA041) JP1 DISP (CN072) EXCT (CN073) FILTER (JP001) (CN070) CHK (CN071) FAN DRIVE GRL (CN032) (CN020) T10 (CN061) POWER LED (D002) EEPROM (IC010) T10: 6 plug (yellow): used for remote control. (Refer to the remote control section) (CN061) 1 - start/stop input 2 - CO ...

  • Sanyo SPW-UMR164EXH56 - page 15

    4. FUNCTIONS 4-1 Room temperature control 15 ...

  • Sanyo SPW-UMR164EXH56 - page 16

    4-2 Automatic control for heating and cooling 16 ...

  • Sanyo SPW-UMR164EXH56 - page 17

    5. REPLACING PCB 5-1 Replacing PCB About EEPROM (Erasable Programmable Read-Only Memory) EEPROM is a component in which the various information necessary for functionning can be electronically written or erased. This component holds informations that is essential for the running of the unit, and must be handled with care. D002 led lamp (red) 17 ...

  • Sanyo SPW-UMR164EXH56 - page 18

    5-2 How to replace PCB 18 ...

  • Sanyo SPW-UMR164EXH56 - page 19

    5-3 How to replace EEPROM with EEPROM included in PCB service pack 19 ...

  • Sanyo SPW-UMR164EXH56 - page 20

    20 ...

  • Sanyo SPW-UMR164EXH56 - page 21

    5-4 Table of settings 21 ...

  • Sanyo SPW-UMR164EXH56 - page 22

    6. SERVICING AND MAINTENANCE FUNCTIONS 22 ...

  • Sanyo SPW-UMR164EXH56 - page 23

    7. TROUBLE DIAGNOSIS 7-1 Contents of remote controller switch alarm display 23 ...

  • Sanyo SPW-UMR164EXH56 - page 24

    24 ...

  • Sanyo SPW-UMR164EXH56 - page 25

    7-2 Outdoor unit control panel LED display 25 ...

  • Sanyo SPW-UMR164EXH56 - page 26

    7-3 Trouble indications and inspection points 26 ...

  • Sanyo SPW-UMR164EXH56 - page 27

    27 ...

  • Sanyo SPW-UMR164EXH56 - page 28

    7-4 Remote controller servicing functions 28 ...

  • Sanyo SPW-UMR164EXH56 - page 29

    7-5 Super W-Multi alarm codes 29 ...

  • Sanyo SPW-UMR164EXH56 - page 30

    30 ...

  • Sanyo SPW-UMR164EXH56 - page 31

    31 ...

  • Sanyo SPW-UMR164EXH56 - page 32

    32 ...

  • Sanyo SPW-UMR164EXH56 - page 33

    33 ...

  • Sanyo SPW-UMR164EXH56 - page 34

    34 ...

  • Sanyo SPW-UMR164EXH56 - page 35

    7-6 Inspection of parts 35 ...

  • Sanyo SPW-UMR164EXH56 - page 36

    36 ...

  • Sanyo SPW-UMR164EXH56 - page 37

    37 ...

  • Sanyo SPW-UMR164EXH56 - page 38

    SANYO Airconditioners Europe S.r.l. Via Bisceglie, No.76 20152 Milano, Italy ...

メーカー Sanyo カテゴリー Air Conditioner

Sanyo SPW-UMR164EXH56のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- SPW-UMR164EXH56の取扱説明書
- Sanyoの製品カード
- パンフレット
- またはSanyo SPW-UMR164EXH56の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Sanyo SPW-UMR164EXH56の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Sanyo SPW-UMR164EXH56の取り付け説明書、サービスマニュアル、簡易説明書、またはSanyo SPW-UMR164EXH56のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Sanyo SPW-UMR164EXH56の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Sanyo SPW-UMR164EXH56デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがSanyo SPW-UMR164EXH56を使用するのを助ける技術的文書のことです。説明書は通常、全てのSanyo SPW-UMR164EXH56ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Sanyoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Sanyo SPW-UMR164EXH56の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははSanyo SPW-UMR164EXH56の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Sanyo SPW-UMR164EXH56に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Sanyo SPW-UMR164EXH56デバイスの基本機能を使うにあたってのヒント。 Sanyo SPW-UMR164EXH56のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Sanyo SPW-UMR164EXH56に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるSanyo SPW-UMR164EXH56のメーカー/サービスへの連絡先に関する情報。

Sanyo SPW-UMR164EXH56についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもSanyo SPW-UMR164EXH56の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがSanyo SPW-UMR164EXH56で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)