    Global leaders in sleep and respiratory medicine www .m yr esmed.com 26869/2 06 04 VP AP Adapt S V User US A ENG Bleed this panel onto spine (if applicable) but NOT onto Front Cover Front Cover - User.qxp 05/04/2006 4:31 PM Page 2 ...

  • ResMed Adapt SV System - page 3

    VP AP ™ Ad a p t S V User Guide English Reorder numb er: 26869/2 06 04 ...

  • ResMed Adapt SV System - page 4

    ResMed Ltd (Manufacturer) 1 Elizabeth MacArthur Drive B ella Vista NSW 21 53 Australia ResMed Corp (US Designated Agent) 1 4040 Danielson Street Po way CA 92064-6857 USA ResMed (UK) Ltd (EU Authorized R epre sentative) 65 Milton P ark Abingdon Oxfordshire OX1 4 4RX UK ResMed Offices Australia, A ustria, Finland, France, Germany , Hong Kong, Japan, ...

  • ResMed Adapt SV System - page 5

    i Cont ents Cont ents Introduct ion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 VP AP™ A dap t S V 1 User/owner responsibility 1 Definitions 1 Medical Inf ormation 1 Intended Use 1 Contraind ications 1 W a rnings 2 Cautions 2 Quic k S etup Guide . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • ResMed Adapt SV System - page 6

    ii Cleaning and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Daily 31 W eek ly 31 P eriodically 32 Air Filter 33 Hypoall ergenic Ai r Filter 33 Ser vicing 33 T roublesho oting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Glossary . . . . . . . . . . . . . . . . . . . . . . ...

  • ResMed Adapt SV System - page 7

    1 Intr oducti on Introduction VPAP ™ Adapt SV The VP AP ™ Ada pt SV flow generator h as been des igned to be re liable, comfortabl e and ea sy to use . You can ob serve yo ur treatment and mak e adju stments t o settin gs usin g a keypa d and LCD sc reen. ! CAUTION USA federal la w restricts this device to sale by or on the order of a phy sicia ...

  • ResMed Adapt SV System - page 8

    2 • impaire d ability to c lear secr etions • pneumoth orax or pn eumomedi astinum • recen t cran ial trauma or su rgery • c hronic h ypov entilation . Below ar e gener al w ar nings and caution s. Fur ther specific w ar nings, cautions an d notes appear next to th e rel ev ant instr uctions in the manual. ! Warnings • The VP AP Adapt SV ...

  • ResMed Adapt SV System - page 9

    3 Intr oducti on The follow ing sid e effects m a y ar ise during a co urse of the rapy with the VP AP A dapt SV: • dryin g of the no se, mouth, or throat • bloatin g • ear or si nus dis comfort • ey e irritation • skin r ashes • c hest disc omfor t. ...

  • ResMed Adapt SV System - page 10

    4 ...

  • ResMed Adapt SV System - page 11

    5 Quick S etup Guid e Quick Setup Guide 1 Attach the a ir tubing a nd pressu re sensor tu be to the VP AP Adapt SV an d mask (page 9). 2 Attach a h umidifier if req uired (pa ge 11). 3 Switch on the VP AP Adapt S V. Make sure the mask is un blocked. 4 Select the mask settin g (page 2 2). 5 Perform the Ai r Circuit Learn function (pa ge 22) at first ...

  • ResMed Adapt SV System - page 12

    6 ...

  • ResMed Adapt SV System - page 13

    7 VP AP Adapt SV System VPAP Adapt SV Syste m VPAP Adapt SV Componen ts The VP AP Adapt SV flo w generator is supp lied w ith air tubi ng and a pow er cord. Masks a re suppli ed separate ly , as you and your c linicia n hav e to decide w hic h mas k is best for you. Masks that ca n be used w it h VP AP Adapt SV are lis ted on page 8. Some peo ple e ...

  • ResMed Adapt SV System - page 14

    8 Figu re 3 : Ai r tu bing fu lly a ssembl ed All neces sary ai r tubing co mponents are packed with the VP AP Adapt SV: • a 6’6" (2 m) length of air t ubing • a press ure sensor t ube (to me asure press ure at the m ask) w ith Luer connec tors • tube clip s (to ho ld the p ressu re sens or tube ont o the a ir tubing) • a pro ximal c ...

  • ResMed Adapt SV System - page 15

    9 VP AP Adapt SV System Assembling the VPAP Ada pt SV System Complete th e followi ng steps to a ssemble the VP AP A d apt SV syste m. Mak e sure the area around the uni t is clean (dus t free) and clear of be dding, clo thes and any other pote ntial blockag es. To add a humidifie r see pag e 11. ! WARNI NG Use only the air tub ing system su pplied ...

  • ResMed Adapt SV System - page 16

    10 2 Connect air t ubing Connect the air tube fir mly ont o the air ou tlet at the fr ont of the unit . Figu re 4: Fron t vi ew of VPAP Adapt SV T o attach the pres sure se nsor tube to the unit , screw the Luer connector on to the sock et on the side of the unit . Figure 5: Tw isting the Luer lock conne ctors together ! WARNI NG Use care wh en han ...

  • ResMed Adapt SV System - page 17

    11 VP AP Adapt SV System Humidifiers A humidifie r may be required if you are e xperienci ng dryness of the nose , throat , or mouth. Th e followi ng ResMed humidifi ers are comp atible wi th the VP AP A dapt SV: Figu re 7: H umi difiers compat ible with the VP AP Ad apt SV When using a humidifier, stop the VP AP A dapt SV by using the Start/Stop k ...

  • ResMed Adapt SV System - page 18

    12 HumidAire 2i™ The Hum idAire 2i p rovides hea ted humidi fication for the VPAP Ad apt SV. To attach the HumidAire 2 i , remove the VP AP Adapt SV front cover and a ttach the hum idifier do cking st ation and water ch amber. N o other acces sories ar e required for use . Plea se refer to the HumidAire 2i User’s Ma nual for details . Once you ...

  • ResMed Adapt SV System - page 19

    13 VP AP Adapt SV System HumidAire™ You will ne ed a medium size 21" (52 cm ) air tube to co nnect the VP AP Adap t SV unit to the HumidAire™ (see Fi gure 7). 1 Make sure bo th the HumidAire and th e VP AP A dapt SV a re turned off. Fill the HumidAire with w ater as des cribed in the humidifie r manual. Pl ace the filled water c hamb er in ...

  • ResMed Adapt SV System - page 20

    14 5 Connect the mask sys tem to the fre e end of th e long air tub ing. The fi nal assembl y should look like t his: 6 Switch on the HumidAire and the VP AP A dapt SV. ! WARNI NG Make sure that the powe r cords and p lugs are in g ood condition and the equipment is not damaged . 7 Perform the Ai r Circuit Learn function (se e page 22). For informa ...

  • ResMed Adapt SV System - page 21

    15 VP AP Adapt SV System ResLink™ The Res Link is a de vice that records data onto a Sma rtMedia™ car d during your therapy. T he card can be re turned to yo ur clinician so that they c an observe you r progress a nd adjust fl ow genera tor param eters if nec essary. Th e Re sL i nk connects to the bac k of VP AP Ada pt SV as shown. F or full d ...

  • ResMed Adapt SV System - page 22

    16 Using DC Power to Run t he VPAP Adapt SV The VPAP Adapt SV ca n be run on DC in case of power fail ure. ResMed su pplies separately a co nverter that al lows a 12 V or 2 4 V battery to be con nected to the DC inpu t of the VP AP Adapt S V. When using D C, power is turned on and off via the switch o n the connec tor that connec ts the DC-DC conve ...

  • ResMed Adapt SV System - page 23

    17 Using th e VP AP Adap t SV Using the VPAP Adapt SV ! WARNI NG Before starting therapy with a new ma sk select the correct mas k type in the Settings menu (page 22 ). When adding or removing a ne w component su ch as a mask, h umidifier, or anti -bacterial filter, pe rform the Air Circuit Lea rn function (page 22). Starting Treatm ent When the sy ...

  • ResMed Adapt SV System - page 24

    18 Control Panel Functions The contro l panel o f the VP AP Adapt SV has a ke ypad tha t allo ws you to : • start or stop treatm ent • adjust set tings on the flow generato r • mute o r stop alarms • view treatm ent dat a. Figure 13: The VPAP Adapt SV control panel LCD s creen Displays informati on about fl ow generat or setting s, alarm s ...

  • ResMed Adapt SV System - page 25

    19 Using th e VP AP Adap t SV Left k ey (green) • Enters a menu. • Confirms and appl ies set tings. • P erforms the function indicated by the tex t abov e it in the LCD (eg, ’enter ’ , ’c hange’). Right k ey (red) • P erforms the function indicated by the te xt abov e it in the LCD (eg, ’exit’). • Cancels operatio ns. • Exte ...

  • ResMed Adapt SV System - page 26

    20 To chang e a settin g, press t he Up /Down key un til you a rrive at the men u you require. • P ress the Left k ey to enter the menu, then use the Up/Down k ey again t o scroll throu gh the options. • Once y ou find the option y ou require pres s the Left k ey to select the func tion that is d isplay ed in the bot tom le ft of the screen (eg ...

  • ResMed Adapt SV System - page 27

    21 Using th e VP AP Adap t SV Menus The option s available in the Setti ngs menu will dep end on the therapy y ou are receivin g (either ASV or CPAP mode ), as set by your clinic ian. Figur e 15: Navigating the Patient menu A VG PRESS: 10.4 SW: SX432-0100 VP AP Adapt SV ASV MODE SOUND LEVEL:LOW SOUND LEVEL:LOW These menus appe ar only if at least o ...

  • ResMed Adapt SV System - page 28

    22 Setti ngs Menu You will only see the option s releva nt to your th erapy. In CPAP ( Continuous Positive Airw ay Pressure) mo de, the clini cian sets a p ressure that w ill be constant throughout t reatment. In ASV mode, the VP A P Adapt SV continua lly meas ures yo ur brea thing and regu lates t he air pr essure accord ingly. Mask Select the typ ...

  • ResMed Adapt SV System - page 29

    23 Using th e VP AP Adap t SV 7 . When the functio n is comple te, a screen w ill appe ar say ing that the circ uit has bee n learned successfu lly . The ne xt menu item is then dis play ed. Commenc e treatment as describe d in “Starting T reatment” on page 1 7. If there i s a probl em with th e circuit a s creen sa ying ’Inva lid circu it’ ...

  • ResMed Adapt SV System - page 30

    24 Mask-fit Gives a rating of how well th e mask wa s fitting du ring your last sessi on on the VP AP Adapt SV. T he stars in dicate ho w good the fi t was (more stars = be tter fit). Aver age Pressure Provides informatio n on the a verage air pr essure du ring your mos t recent session on the VP AP Adapt SV . Usage Tells yo u how lon g the VP AP A ...

  • ResMed Adapt SV System - page 31

    25 Using th e VP AP Adap t SV Servicing Men u This men u displays the followin g informat ion: • SN—the flo w generator’ s serial num ber • PCB—the flo w gen erator’ s PCB numbe r (PCB—printed circuit bo ard) • SW—the version of sof tware cu rrently installed on the fl ow genera tor . Treatment Screens There are th ree Treatm ent ...

  • ResMed Adapt SV System - page 32

    26 ...

  • ResMed Adapt SV System - page 33

    27 Ala rms Alarms The VP AP Adapt S V unit is fitted with alarm s to alert you to c hanges tha t will aff ect your t reatmen t. The m ost comm on reason for an al arm to sou nd is because the system has not been pro perly assem bled. Check tha t the air tubin g and pr essure sen sor tube have be en properl y attached to the fl ow gene rator and mas ...

  • ResMed Adapt SV System - page 34

    28 Will clea r when: • the lo w press ure cond ition is fix ed • treatment is stoppe d by pressing the Start/Stop key . Power Fa il Alarm Triggered by: • pow er failure • mac hine is di sconnected or s wit c h ed of f while deliv ering treatment . If a po wer fail al arm sounds: • the flo w gene rator stops deliv ering air pr essure. Will ...

  • ResMed Adapt SV System - page 35

    29 Ala rms • c hec k that the air t ube and s ensor t ube are connecte d properly . Will stop when: • the m ask leak ha s been rectifi ed. Note : The High Lea k alarm can be tu rned off in the Leak Alert option in t he Settings m enu. Insufficient Pressure Support Alarm Triggered by: • air pres sure at the mask has fail ed to reac h an exp ec ...

  • ResMed Adapt SV System - page 36

    30 ...

  • ResMed Adapt SV System - page 37

    31 Cleani ng and Maint enance Cleaning and Maintenance You shoul d regularl y carry out th e cleaning and mai ntenance des cribed i n this manual. ! CAUTION Do not wash the pressure sensor tube. If fl uid enters the pressure s ensor tube allow i t to dry comple tely by han ging it in a c lean place out of direct sunlight . If the pressure s ensor t ...

  • ResMed Adapt SV System - page 38

    32 Figure 19: Air tubing as sembly removed for cleaning ! CAUTION • Do not use b leac h, c hlorine-, alcohol- , or aromatic-base d solutions (including all sc ented oils), moisturising or antibac terial soaps to clean the cushion, mask, air tubing, or the VP AP Adapt SV . These solutions may caus e hardening and reduce the life of the product. ? ...

  • ResMed Adapt SV System - page 39

    33 Cleani ng and Maint enance Air Filter Inspect th e air filter every month and check if it is blocked by dirt or co ntains holes. The filter s hould be replaced every six months, or more often i f the flow generator i s operati ng in a du sty environ ment. ! WARNI NG Do not wash the air filter onc e it has be come soil ed. The air fil ter is not ...

  • ResMed Adapt SV System - page 40

    34 apparent, you should exe rcise caution an d have the devi ce inspe cted by a n authorize d ResMed service cen ter. If you feel the u nit is not perfo rming proper ly, see “Troubl eshootin g” on page 35 . ! CAUTION Inspection and repair sho uld only be p erformed by an authorized serv ice agent. Unde r no circumstan ces shoul d you attempt to ...

  • ResMed Adapt SV System - page 41

    35 T roubles hootin g Troubleshooting If there is a problem , try the foll owing sugg estions. If the probl em cannot be solved, c ontact y our equipmen t supplier or ResMed. Do not atte mpt to open the flow gene rator. Prob lem Possible ca use Sol utio n Insuf ficient air deliv ered from flow generator Air filter is dirty . Replace air filter . Ai ...

  • ResMed Adapt SV System - page 42

    36 ...

  • ResMed Adapt SV System - page 43

    37 Glossary Glossary Alarms When more th an one a larm is a ctivate d at the on e time, the highest pr iority alarm will be display ed. Backlight The ba c kl ight turns of f if no but to n has be en pres sed for t wo minu tes. It can also be k ept permanently on b y selecting A uto in the B ac klight scre en of the Option s menu. bpm breaths pe r m ...

  • ResMed Adapt SV System - page 44

    38 ...

  • ResMed Adapt SV System - page 45

    39 T ech nical Sp ecifica tions Technical Specifications Dime nsions (H x W x D) 5.6" x 9.8" x 11.5" (142 mm x 248 mm x 293 mm) Weight Flow gen erator with cover: 8. 14 lb (3.7 kg) Flow gen erator with Humi daire 2i (empty): 9.24 l b (4.2 kg ) Environmental condition s Ope ratin g temper ature : 41 o F to 104 o F (+5 o C to +40 o C) ...

  • ResMed Adapt SV System - page 46

    40 • Insuf ficie nt pressu re support ala rm Is trigger ed if for 3 br eaths in a row th e maximum m ask pressu re ac hiev ed at inspira tor y to expirato r y transition is either <87 .5% of the absolu te mask pressure target ted at that poi nt, or < absolute mask pre ssure targeted min us 1 cm H 2 O , whic heve r is the lo wer . • High l ...

  • ResMed Adapt SV System - page 47

    41 T ech nical Sp ecifica tions T able 4: Maximum lo w impedance f low at stated pressures Pressure (c m H 2 O) Flow (L/min) 4.2 21 7 8.6 218 13 . 0 2 19 ...

  • ResMed Adapt SV System - page 48

    42 Mask sett ing: flow/pre ssure ch aracter istics Glossary of symbols Read the op erating ma nual be fore using Type CF eq uipment AC switch Class II e quipment 0 10 20 30 40 50 60 0 5 10 15 20 25 Fu ll Face Act iv a Ultra Vi sta Press ure (c m H 2 O) Flow ( L/min) ...

  • ResMed Adapt SV System - page 49

    43 T ech nical Sp ecifica tions Guidance and Manufact urer’s Declaration — Electromagnetic Emissions and Immunit y Guidance and manufactur er ’ s declaration – electromagnetic emissions The VP A P Adapt SV is inten ded for use in the ele ctromagnet ic environment specified below . The customer or the user o f the VP AP Adapt SV should assur ...

  • ResMed Adapt SV System - page 50

    44 (Continued nex t page) Guidance and manufactur er ’ s declaration – electromagnetic immunity The VP A P Adapt SV is inten ded for use in the electr omagnet ic environment specified be low . The customer or the user o f the VP AP Adapt SV should assure that it is used in suc h an environment. Immunity t est I E C 6 0 6 01- 1- 2 tes t l eve l ...

  • ResMed Adapt SV System - page 51

    45 T ech nical Sp ecifica tions Guidan ce and manuf actur er ’ s declar ation – ele ctro magnetic im munity (c ontinued) The VP AP Adapt S V is inten ded for use in the electromagnet ic environment sp ecified below . The cu stomer or the us er of the VP AP Adapt SV should assu re that it is us ed in such an environment. Immunit y tes t I E C 6 ...

  • ResMed Adapt SV System - page 52

    46 Reco mmended s eparat ion dis tances betw een por table and mobile RF communi cation s equipment and the VP AP Adapt S V The VP AP Adapt SV is inte nded for use in an environment in which radiated R F disturbance s are contr olled. The custome r or the u ser of the V P AP Adapt SV can h elp prevent electr omagnetic interference by maint aining a ...

  • ResMed Adapt SV System - page 53

    47 Limited W arranty Limi ted Warrant y ResMed wa rrants that yo ur ResMed product shall b e free from d efects in material and workmansh ip for the perio d specified below fro m the date of purchase by the initi al consu mer. This warranty is not transferab l e. Not e: Some m odels are not availa ble in a ll regions . If the produc t fails under c ...

  • ResMed Adapt SV System - page 54

    48 ...

  • ResMed Adapt SV System - page 55

    49 Index Index A Ai r Circu it L earn fu nction 22 air filt er 33 hy po-all erge nic 33 air pre ssure monitorin g 24 air tubi ng at t aching to mask 10 cleaning 31 conne cting 10 air tubi ng sy stem 7 , 8 , 10 alarm flow bloc ked 29 high lea k 28 high p ressure 28 low mask pres sure 27 power fail 28 alarm LED 19 anti- bacteri al filt er 15 B bac k ...

  • ResMed Adapt SV System - page 56

    50 S yst em Er ror 7 mess age 35 T trea tmen t scr eens 25 U user/owner responsi bility 1 V VP AP Adapt SV 7 usage 24 ...

メーカー ResMed カテゴリー Respiratory Product

ResMed Adapt SV Systemのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Adapt SV Systemの取扱説明書
- ResMedの製品カード
- パンフレット
- またはResMed Adapt SV Systemの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、ResMed Adapt SV Systemの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、ResMed Adapt SV Systemの取り付け説明書、サービスマニュアル、簡易説明書、またはResMed Adapt SV Systemのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、ResMed Adapt SV Systemの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

ResMed Adapt SV Systemデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがResMed Adapt SV Systemを使用するのを助ける技術的文書のことです。説明書は通常、全てのResMed Adapt SV Systemユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

ResMedの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. ResMed Adapt SV Systemの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははResMed Adapt SV Systemの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。ResMed Adapt SV Systemに関してこのドキュメントで見つけることができる全てのヒントの目次
3. ResMed Adapt SV Systemデバイスの基本機能を使うにあたってのヒント。 ResMed Adapt SV Systemのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。ResMed Adapt SV Systemに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるResMed Adapt SV Systemのメーカー/サービスへの連絡先に関する情報。

ResMed Adapt SV Systemについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもResMed Adapt SV Systemの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがResMed Adapt SV Systemで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)