Datalogic Scanning 1100I OEMの取扱説明書

16ページ 0.36 mb
ダウンロード

ページに移動 of 16

Summary
  • Datalogic Scanning 1100I OEM - page 1

    Magellan TM 1100i OEM Pr esentation Omnidir ec tional Bar C ode Reader Integr a tion Manual ...

  • Datalogic Scanning 1100I OEM - page 2

    Datalogic Scanning, Inc. 959 T err y Street Eugene, Oregon 974 02 USA T eleph one: (541) 6 83-5700 F ax: (541) 345- 7140 An Unpublished Work - All rights reserved. No par t of the contents of this do cumentation or the procedures described therein may be repr oduced or transmitted in any f orm or by any means without prior writt en permission of Da ...

  • Datalogic Scanning 1100I OEM - page 3

    T able of C ont ents Overview ............ .......... ............. ........... .......... ............. .......... ............. .......... ........... ..... ..... 1-1 Resources in other docu ments .......... ............. ............ ............. ............. ............ ............. ........ 1-1 Unpacking the Scanner .......... ............ ...

  • Datalogic Scanning 1100I OEM - page 4

    NO TES Magellan ® 1100i OEM i-2 ...

  • Datalogic Scanning 1100I OEM - page 5

    Secti on 1 Intr oduc tion This document gives instruction, mechanical deta ils, and design considerations to inte- grate the Magellan 1100i OEM model (designate d as “ scanner ” or “OEM scanner” in this manual) specifically into equip ment-integrated scanning applications. Ov er vi ew The OEM scanner is a compact, decoded, om ni-directional ...

  • Datalogic Scanning 1100I OEM - page 6

    Introduction Unpacking the S canner The scanner is shipped in custom packaging. Carefully open the package, and inspect for the following: • scanner • power supply (if or dered) • interface cable (if ordered) If any parts are damaged or you need additional har dware, please contact T echnical Suppor t . Scanner Care The scanner contains sensi ...

  • Datalogic Scanning 1100I OEM - page 7

    Secti on 2 Mounting the Scanner This section describes how to design the mounting for optimum scanner performance. General C onsider ations A typical system uses the sca nner mounted inside a host encl osure, with an opening for the scanning pattern to exit and read bar code s. The opening should be the size of the scanner window at a minimum, but ...

  • Datalogic Scanning 1100I OEM - page 8

    Mounting the Scanner Cab le R ou ti ng The mounting design should also take into consideration the clea rances needed for the interface cable. This cable should be routed internal to the host enclosure as much as possible. I t is recommended to use a flat cable or round cable without a large strain r elief so that the cable can be routed away from ...

  • Datalogic Scanning 1100I OEM - page 9

    Design of the Scanner Opening Second, the scanner must be positioned so that the scan volume and illumination light will cov er the entire bar code. The scan volume is shown in Figu re 2-2 . The combina- tion of the Scan V olume and the illumination light is called the F ield of View . Design- ing around the scanner F ield of View is explained more ...

  • Datalogic Scanning 1100I OEM - page 10

    Mounting the Scanner Integra ting the Sc anner Behind a W indow It is not recommended to place any type of additional wi ndow between the scanner and the bar code to be read. The addition of a host encl osure windo w will significantly degrade scanner performance. This is due to the additional op tical reflective surfaces that will cause interfer - ...

  • Datalogic Scanning 1100I OEM - page 11

    Appendix A T echnical Specificat ions Optical and Read P er formanc e Par ameters Pa rameter Specification Scan V olume 1147 cm 3 / 70 in 3 Scan P attern 136 scan lines Scan Rate 1760 Digital Scan Lines/second Minimum Resolution 5 mil Depth of Field (100% UPC Labels) Code Size Depth of Field 5 mil 25.4 - 57.2mm / 1.0 - 2.25” 7.5 mil 12.7 - 69.9mm ...

  • Datalogic Scanning 1100I OEM - page 12

    Technical Specifications Environ ment al Para meter s Pa rameter Specification Mechanical Shock Multi 1.0m drops Contaminants W ater and Dust IP52 T emperature Ranges: Operating Storage 32  F to +122  F (0  C to +50  C) -104  F to +158  F (-40  C to + 70  C) Ambient Light Indoor 0 - 6000 lux Ambient Light Outdoor 0 - 86,100 ...

  • Datalogic Scanning 1100I OEM - page 13

    Appendix B Mechanical Specifications Ph y sical Proper ties Pa rameter Specification Dimensions 86.4 mm x 71.1 mm x 66.0 mm ( 3.4” x 2.8” x 2.6”) W eight ~ 198 g / 7.0 oz. Scanner Dimensions Integration Manual B-1 ...

  • Datalogic Scanning 1100I OEM - page 14

    Mechanical Specifications Clearanc e Required f or Integration Magellan ® 1100i OEM B-2 ...

  • Datalogic Scanning 1100I OEM - page 15

    ...

  • Datalogic Scanning 1100I OEM - page 16

    Aus tral ia Datalogic Scanning Pty Ltd T elephone: [61] (2) 9870 3200 australia.scanning@datalogic.com Fr ance and Benelux Datalogic Scanning SAS T elephone: [33].0 1.64.86.71.00 france.scanning@datalogic.com Ger man y Datalogic Scanning GmbH T elephone: 49 (0) 61 51/93 58-0 germany .scanning@datalogic.com Indi a Datalogic Scanning India T elephone ...

メーカー Datalogic Scanning カテゴリー Barcode Reader

Datalogic Scanning 1100I OEMのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 1100I OEMの取扱説明書
- Datalogic Scanningの製品カード
- パンフレット
- またはDatalogic Scanning 1100I OEMの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Datalogic Scanning 1100I OEMの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Datalogic Scanning 1100I OEMの取り付け説明書、サービスマニュアル、簡易説明書、またはDatalogic Scanning 1100I OEMのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Datalogic Scanning 1100I OEMの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Datalogic Scanning 1100I OEMデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがDatalogic Scanning 1100I OEMを使用するのを助ける技術的文書のことです。説明書は通常、全てのDatalogic Scanning 1100I OEMユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Datalogic Scanningの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Datalogic Scanning 1100I OEMの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははDatalogic Scanning 1100I OEMの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Datalogic Scanning 1100I OEMに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Datalogic Scanning 1100I OEMデバイスの基本機能を使うにあたってのヒント。 Datalogic Scanning 1100I OEMのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Datalogic Scanning 1100I OEMに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるDatalogic Scanning 1100I OEMのメーカー/サービスへの連絡先に関する情報。

Datalogic Scanning 1100I OEMについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもDatalogic Scanning 1100I OEMの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがDatalogic Scanning 1100I OEMで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)