Emerson KF100AP01 - page 1
Net Weight: 30.0 Lbs. Part No. F40BP72800004 Form No. BP7280-4 U.L. Model No.: KF100 READ AND SA VE THESE INSTRUCTIONS KF100AP01 Antique P ewter with Natural Cher r y/Mahogany Blades KF100DBK01 Distressed Black with Distressed Black/Natural Cher r y Blades OL YMPIA Ceiling Fan Owner's Manual Emerson F ans Designed by KF100OZ01 Olde Bronze ¨ w ...
-
Emerson KF100AP01 - page 2
W ARNING: T o avoid fire, shock, and serious personal injury , follow these instructions. Safety Instructions 1. Read your owner ’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidental ...
-
Emerson KF100AP01 - page 3
T ools Needed for Assembly One Phillips head screwdriver One wire stripper One stepladder Three 60-watt (max.) candelabra base bulbs Six wire connectors (supplied) Materials Wiring, outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the following sizes: Installed ...
-
Emerson KF100AP01 - page 4
Preset Memory Feature Y our remote control receiver is equipped with a preset memory feature. The receiv- er will remember the light intensity and fan speed when the light and fan are turned off from the wall switch. When the wall switch is turned back on, the lights and fan will resume operation as they were prior to the switch being turned off. I ...
-
Emerson KF100AP01 - page 5
2. Slide the four switch levers on the code switch to your choice of ON (up) or down positions. Use a ball-point pen or small screwdriver and slide the levers firmly up or down. 3. In the receiver (Figure 1), slide the four switch levers to the same positions as set in the transmitter . Make sure the levers on both switches are in the same position ...
-
Emerson KF100AP01 - page 6
5. Reinstall the hanger ball (Figure 5) on the downrod as follows. Route the three 80” motor leads through the hanger ball and slide the hanger ball over the downrod. Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight aga ...
-
Emerson KF100AP01 - page 7
11 . Engage the connector of the switch housing/light fitter assembly with the motor connector (Figure 8). The two connectors are color-coded and must be mated correctly (color-to-color) before they can be engaged. Make sure the connectors close properly . 12. Partially install two 8-32 x 7mm pan head screws (supplied) into two of the threaded hole ...
-
Emerson KF100AP01 - page 8
2. Carefully lift the fan and seat the hang- er ball/downrod assembly on the hang- er bracket that was just attached to the outlet box (Figure 12). Be sure the groove in the ball is lined up with the tab on the hanger bracket (Figure 1 1). 8 How to Hang Y our Ceiling Fan The fan must be hung with at least 7' of clearance from floor to blades ( ...
-
Emerson KF100AP01 - page 9
9 1. Position the supply wires to the left side of the outlet box (Figure 13); position the fan wires to the right side. Partially insert the remote control receiver (flat side up) until one end rests on the hanger ball as shown in Figure 13. NOTE: Make all wiring connections using wire connectors (supplied). Make sure that all connections are tigh ...
-
Emerson KF100AP01 - page 10
7. Screw three 60-watt (maximum) cande- labra base bulbs into the light fitter sockets (Figure 16). 8. Place the lower glass in the lower ring assembly (Figure 16). Unscrew four bracket mounting screws from the four lower ring posts. SOCKET LOWER RING ASSEMBL Y POST LOWER RING BRACKET BRACKET MOUNTING SCREW (4) LOWER GLASS 60-WA TT CANDELABRA BASE ...
-
Emerson KF100AP01 - page 11
NOTE: Slightly loosen the four screws securing the lower ring brackets to the switch housing assembly . 9. Securely grasp one of the lower ring posts and raise the lower ring up to one of the lower ring brackets. Secure the lower ring post to the lower ring brack- et using a bracket mounting screw (Figure 16). Grasp the opposite post and secure the ...
-
Emerson KF100AP01 - page 12
12 Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock. ! W ARNING The use of any other control not specifically approved for this fan could result in fire, shock and per- sonal injury . ! W ARNING This product is designed to use only those parts supplied with th ...
-
Emerson KF100AP01 - page 13
13 T rouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch start. blown. circuit fuses or circuit breakers. 2. Loose power line 2. Check line power connections connections to the fan, or to fan and wire. loose wire connections in the switch housing. 3. W all switch is off. 3. Tur ...
-
Emerson KF100AP01 - page 14
14 Repair Parts 16 17 3 2 1 5 4 7 6 14 18 19 15 23 25 24 22 21 9 8 11 10 12 13 26 FAN/OFF FOR/REV LIGHT DIMMER HI MED LOW ® 20 BP7280, Olympia, KF100 7/31/06 10:57 AM Page 14 ...
-
Emerson KF100AP01 - page 15
Part Numbers Key Model No. Model No. Model No. N o . Description KF100AP01 KF100DBK01 KF100OZ01 * Hanger Pack, Consisting of: 761655-34 761655-36 761655-35 1 Bracket, Hanger Assembly (1) — — — 2 Ball, Hanger (1) — — — 3 Downrod (1) — — — * Parts Bag, Containing: 762655 762655 762655 4 Wire Connector (6) — — — 5 Stud, Threade ...
-
Emerson KF100AP01 - page 16
LIMITED WARRANTY What The War ranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. Y ou must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor , this warranty will la ...