New Buck Corporation 91の取扱説明書

29ページ 0.45 mb
ダウンロード

ページに移動 of 29

Summary
  • New Buck Corporation 91 - page 1

    Model 91 Bay Heater Fir eplace Insert & Freestanding FEA TURES PREP ARA TION INST ALLA TION OPERA TION MAINTENANCE SAFETY Contact your insurance company for co verage and installation inspection SAFETY NOTICE If this heater is not properly installed, a house fi re may result. For your safety, follow the installation directions. Contact local bu ...

  • New Buck Corporation 91 - page 2

    T ABLE OF CONTENTS SECTION I Room Heater Features ................................................................................................... 3 Important Statements .................................................................................................... 3-6 SECTION II Masonry Insert In stallation ................................ ...

  • New Buck Corporation 91 - page 3

    ...

  • New Buck Corporation 91 - page 4

    SECTION I The New Buck Corporation room heater Model 91 Bay is one of the safest and most efficient heating systems available when in stalled and operated as specified in thes e instru ctions and as stipul ated on the operation and installation labels affixed to the unit. The unit is d esigned to burn wood fuel only. Please read this entire manual ...

  • New Buck Corporation 91 - page 5

    EP A COMPLIANCE ST A TUS This manual describes the installation and operation of the New Buck Corporation Model 91 Bay wood heater. These heaters meet the U.S. Environmen tal Protection Agency’s Emission limits for wood heaters sold after July 1, 1992. Under specific test conditio ns this heater has been shown to deliver h eat at rates ranging fr ...

  • New Buck Corporation 91 - page 6

    CA T AL YST EQUIPPED This wood heater contains a cataly tic combustor, which needs periodic inspection a nd replacem ent for proper operation. It is against the law to operate this wo od heat er in a manner inconsistent with operating instructions in this manual or if the catalytic element is deactivated or removed. CA T AL YST W ARRANTY The combus ...

  • New Buck Corporation 91 - page 7

    CA T AL YST MONIT ORING It is important to periodically monito r the operation of the catalytic combustor to ensure that it is functioning properly, and to determine when it nee ds to be replaced. A non-functioning com busto r will result in a loss of heating ef ficiency , and an incr ease in creo sote and emis sions. See Troublesho oting sec tion ...

  • New Buck Corporation 91 - page 8

    SECTION II MASONR Y INSER T INST ALLA TION INST ALLA TION OPTIONS This unit (appliance) may be installed into an all masonry fireplace, built in accordance with the Unifor m Building Code and the National Fire Protection Association (NFPA 211). NOTE: Check with local building officia ls for any permits required for installation of this stove and no ...

  • New Buck Corporation 91 - page 9

    FIGURE 1 FIREPLACE INSERT 30" 20" 15" 20" 8" 24" HEARTH EXTENSION MANTEL INST ALLA TION (Fir eplace Insert) Minimum Clearances to Combus tible Materials (in inches) TRIM PANELS OPTION (B) OPTION (C) SEAL TRIM PANELS WITH INSULATION / AND OR HIGH TEM- PERATURE CAULK REMOVE DAMPER OR WIRE IT OPEN AIRTIGHT INSULATED CLEAN ...

  • New Buck Corporation 91 - page 10

    REQUIRED FIREPLACE DIMENSIONS Minimum fireplace dimensions: Height Widt h Dep th Min. Min. Min. Model 91 Bay 23 1/ 2" 31 3/4" 15 1/2" POSSIBLE T OOLS NEEDED FOR INST ALLA TION If you decide to install your own stov e, there are several hand too ls you may need to do the job. If you do not already have them, they are readily available ...

  • New Buck Corporation 91 - page 11

    POSITIONING THE HEA TER When positioning the h eater, the following conditio ns MUST be m et! (See Figure 2 .) 1. The front of the damper opening must be po sitioned BEHIND the rear edge of the lintel to ensure proper draft. (See Figure 2.) 2. The vertical plane of the fire place front must fall BEHIND the side panels of the unit. (In other words, ...

  • New Buck Corporation 91 - page 12

    7. Slide the unit back i nto the fireplace. Check to be sure that the trim pane ls are prope rly positioned and li e flat against the front of the fireplace. If one or more of the pa nels is out of position, slide t he unit out and reset by loosening t he mount ing screws a nd reposi tioning i n the slot. 8. Reinstall the top trim panel by sliding ...

  • New Buck Corporation 91 - page 13

    SECTION III RESIDENTIAL FREEST ANDING ROOM HEA TER INST ALLA TION INST ALLA TION PRECAUTION Extensive field and laborator y testing has s hown that cataly tic stoves perf orm best as freest anding stoves whe n vented into a mason ry chimney that include th e following: 1. A rain cap is installed on th e chimney. 2. Height of chim ney is at least 15 ...

  • New Buck Corporation 91 - page 14

    MODEL 91 BA Y MINIMUM CLEARANCES The New Buck C orporati on Model 91 B ay must be installed in compliance with the instructions contained in this manual. Clearance from combustible walls and ceilings . (Using single wall chimney connector) The minimum lateral distance between an y part of the ro om heater and combustible walls is shown in Figures 1 ...

  • New Buck Corporation 91 - page 15

    PREP ARING THE ST OVE FOR INST ALLA TION 1. Inspect the u nit for a ny obvious physical da mage. 2. Plug the power cord into a 115V AC outlet. Set switch to “Manual” and rheostat to “High” position to ensure motor operates properly. You cannot check t he motor when the sw itch is in the “Off” or “Autom atic” position, unless a heat ...

  • New Buck Corporation 91 - page 16

    CLOSE CLEARANCE INST ALLA TIONS (in inches) Close clearanc e installati on is possibl e by usi ng the foll owing b rands of bl ack, doubl e-wall chim ney pipe . (See Figure 4 and Figure 5 fo r clearances.) 1. Simpson Dura-Vent d ouble wall chimney connector “Type DVL” and 8" Sim pson Dura- Vent 2100 o HT “Type DP” chimney 2. 8" Se ...

  • New Buck Corporation 91 - page 17

    thimble meets the NFPA-211 Code and local building c odes and is a minim um of 18" from the ceiling. If the connector thimble does not meet these codes , the pass-through connector must be modified. Connectors may pass through walls or partitions constructed of combustible material if the connector is: (a) either listed for wall pass-th rough ...

  • New Buck Corporation 91 - page 18

    Example: The rear clearance for the Model 91 from page 12 is 18" . (See Figure 1.) Thi s clearance may be reduce d by 50% to 9" by using eithe r of the wall protect ion devices ment ioned below. AL TERNA TIVES FOR W ALL PROTECTION Ceiling Exit - Close Clearance 1. Susp end a plumb bob from the ceiling above th e unit so that the weigh t i ...

  • New Buck Corporation 91 - page 19

    Tested and Listed Wall Protector Clearances to combustibles may be reduced if a tested an d listed wall protector is installed over a combustible surface when the followi ng conditions exist: 1. A dead air space of 1" separa tes the listed and tested wall protector from the combustibl e surface. 2. The tested and listed wall protecto r extends ...

  • New Buck Corporation 91 - page 20

    SECTION IV WOOD HEA TER SAFETY Certain safety hazards are inherent in any wood heater in stallation. You should be aware of these so that a safe and proper i nstallati on can be m ade. 1. FAULTY CHIMNE Y: An older masonry chimney should be thoroughly checked to be sure there are no holes or we ak spots w hich could all ow sparks or hot gases to esc ...

  • New Buck Corporation 91 - page 21

    SECTION V OPERA TION This section of t he manual is t o help you get maxim um efficiency a nd maxim um smoke ( particulate) re duction from your heat er. If you s hould experi ence any diffi culty or ha ve questions concerning your heater, c ontact your dealer for assistance. Manufacturer’s recommendatio n for peak performance and long catalyst l ...

  • New Buck Corporation 91 - page 22

    BUILDING A FIRE: 1. Place the “Manual/Off/ Automatic” sw itch in the “Automatic” (bottom) position for thermostat cont rol operation. Turn rheostat knob clockwise (it will click from “Off” position to “On”) so you can v ary the speed of motor. 2. Open the doo r. 3. While looki ng inside firebox, operate the dam per bypass pl ate in ...

  • New Buck Corporation 91 - page 23

    SECTION VI PREVENTIVE MAINTENANCE / P AR TS REPLACEMENT THE CA T AL YSTS The catalysts in your stove are d esigned for many years of use. If af ter several years of use, the efficiency of the stove decreases or if a notable am ount of sm oke is observed, the catalysts ma y need to be replaced. See the Catalyst Warranty prior to replacemen t. The fo ...

  • New Buck Corporation 91 - page 24

    8. Cleaning the catalyst with plain water can redu ce build -up of the catalyst-retarding chemicals. Nothing but a soft brush, low pressu re air or plai n water sh ould be us ed to clean a catalyst. The ceramic unit is fragile i n comparison to the rest of the stove, so it should be handled with care. A soak in warm or hot (not boiling ) water for ...

  • New Buck Corporation 91 - page 25

    MOT OR ASSEMBL Y REPLACEMENT (Motor, Thermostat, Rheostat, Wiring Ha rness) 1. Unplug the heater from the 115V AC outlet. 2. To replace the motor you m ust first take the cover door off. Do this by re moving the two screws holding it i n place. 3. Next, you will find a wire cage prot ecting you from the electri cal com ponents of t his un it. By lo ...

  • New Buck Corporation 91 - page 26

    OFF AUTO/MAIN SWITCH WIRING SCHEMA TIC ...

  • New Buck Corporation 91 - page 27

    SECTION VII TROUBLESHOOTING Operation of any wood heater can create problems. Wh ile the use of a catalytic-combustor equipped stove will substantially lessen so me of these problems– such as cr eosote formation – other tra ditional wood heater pr oblems may remain. The following guidelines apply to op eration of all wood heaters, with problem ...

  • New Buck Corporation 91 - page 28

    3. Backpuffin g 4. Smoke Rollo ut when Heater Door is Opene d 5. Low Catalytic Temperature COMBUSTOR-RELATED PROBLEMS 1. Pluggin g 2. Catalyst Peeling 3. Catalyst Masking 1. Gusts of wind / windy day 2. Hot co mbustor. (Above 1400 o F) 1. Bypass damper i s closed 2. Open ed door too soon af ter opening bypa ss damper 3. Wind gusts blowin g 1. Bypas ...

  • New Buck Corporation 91 - page 29

    NEW BUCK CORPOR ATION (NBC) “LIMITED WARRAN TY” FOR NBC RELATED PRODUCTS PLEASE READ THIS WARRANTY CAREFULLY PRODUCTS COVERE D This warranty covers the new heating unit so long as it is owned by the ori ginal purchaser, including opt ional and standard accessories purchased at the sam e time, subject to terms, limitations, and co nditions herei ...

メーカー New Buck Corporation カテゴリー Fan

New Buck Corporation 91のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 91の取扱説明書
- New Buck Corporationの製品カード
- パンフレット
- またはNew Buck Corporation 91の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、New Buck Corporation 91の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、New Buck Corporation 91の取り付け説明書、サービスマニュアル、簡易説明書、またはNew Buck Corporation 91のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、New Buck Corporation 91の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

New Buck Corporation 91デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがNew Buck Corporation 91を使用するのを助ける技術的文書のことです。説明書は通常、全てのNew Buck Corporation 91ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

New Buck Corporationの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. New Buck Corporation 91の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははNew Buck Corporation 91の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。New Buck Corporation 91に関してこのドキュメントで見つけることができる全てのヒントの目次
3. New Buck Corporation 91デバイスの基本機能を使うにあたってのヒント。 New Buck Corporation 91のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。New Buck Corporation 91に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるNew Buck Corporation 91のメーカー/サービスへの連絡先に関する情報。

New Buck Corporation 91についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもNew Buck Corporation 91の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがNew Buck Corporation 91で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)