  • Lennox Hearth ELDV-35NE - page 1

    OTL Report No. 116-F-39C-5 US Portland MODELS This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a ...

  • Lennox Hearth ELDV-35NE - page 2

    2 T ABLE OF CONTENTS Packaging ......................................... Page 2 Introduction ...................................... Page 2 General Information .......................... Page 2 Requirements for the Commonwealth of Massachusetts . Page 4 New Y ork City Approval ..................... Page 4 Cold Climate Insulation .................... ...

  • Lennox Hearth ELDV-35NE - page 3

    3 W ARNING I mproper installation, adjust - ment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer , service agency or the gas supplier . W ARNING Failure to comply with these i ns t al l at i on in s tr u ct i on s w i ll re s ul t i ...

  • Lennox Hearth ELDV-35NE - page 4

    4 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 2 - Dexen Electronic Gas Valve Pilot Stage T erminal Pressure-T ap (Inlet) Pilot Gas Outlet Supply Gas Inlet Pressure-T ap (Manifold) Burner Stage T erminal Ground (TP) PILOT OUT VENT LO TH TP TH TP HI IN IN Regulator Mounting Screw T est gauge connections are provided on the front of t ...

  • Lennox Hearth ELDV-35NE - page 5

    5 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. • A hard wired carbon monoxide detector with an alarm and battery back-up must be installed on the floor level where the gas fireplace is installed. The carbon monoxide detector must comply with NFP A 720, be ANSI/UL 2034 listed and be ISA certified. • A metal ...

  • Lennox Hearth ELDV-35NE - page 6

    6 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 12 X Roof Pitch is X/12 2 FT MIN. 2 FT MIN. Lowest Discharge Opening H* *H = MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING OF VENT TERMINA TION HEIGHTS FOR VENTS ABOVE FLA T OR SLOPED ROOFS Horizontal Overhang Vertical Wall Vent T ermination Storm Collar Concentric Vent Pipe Flashing 1 ...

  • Lennox Hearth ELDV-35NE - page 7

    7 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. EXTERIOR HORIZONT AL VENT TERMINA TION CLEARANCE REQUIREMENTS Figure 7 V V V V V F C Fixed Closed Window Operable Window B B A B H M I = Area where Termination is not Permitted = Air Supply Inlet X = Vent T ermination V D V 3 ft. 3 ft. A A A = 9” in U.S. = 12” in Canada V L B J X V A G Ins ...

  • Lennox Hearth ELDV-35NE - page 8

    8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 5 (1 27 ) 8-1/4 (2 09 ) 14 (3 56 ) 12 (3 05 ) 17 ( 43 1) *Shelf Height ( see table) Do not insulate the space between the appliance and the area above it. Shelf Above Fireplace With To pV enting 6 (152) 2 (51) 4 (102 ) 6 (152 ) 8 (203 ) 10 (254 ) 12 (305 ) 8 (203) 12 (305) 16 (457) 14 (356) 10 ...

  • Lennox Hearth ELDV-35NE - page 9

    9 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. W ARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifi - ca l ly a pp ro v ed w it h th i s ap pl ia nc e may result in property damage or personal injury . A VER TISSEMENT Risque de dommages ou de bl e ss ur es si le s pi èc es ne so nt ...

  • Lennox Hearth ELDV-35NE - page 10

    10 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. FIREPLACE AND FRAMING SPECIFICA TIONS Vent Size Co-axial DV Vent Size 4-1/2" Inner 7-1/2" Outer Vertical V enting Through the Ceiling: Frame ceiling opening - Use a plumb line from the ceiling above the appliance to locate center of the vertical run. Cut and/or frame an opening, 10- ...

  • Lennox Hearth ELDV-35NE - page 11

    11 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. FIREPLACE FRAMING SPECIFICA TIONS Figure 14 - Corner Framing with Horizontal T ermination Schedule 40 Black Iron Pipe Inside Diameter (Inches) Schedule 40 Pipe Length (feet) Natural Gas Propane Gas 0-10 1/2 3/8 10-40 1/2 1/2 40-100 1/2 1/2 100-150 3/4 1/2 150-200 3/4 1/2 T able 7 Notes: •? ...

  • Lennox Hearth ELDV-35NE - page 12

    12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Step 3. INST ALL THE VENT SYSTEM General Information These instructions should be used as a guideline and do not supersede local codes in any way . Install venting according to local code s, these instru ctions , the curr ent Nat ional Fuel Gas Code (ANSI-Z223.1) in the USA or the current sta ...

  • Lennox Hearth ELDV-35NE - page 13

    13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Note: Convert inches into metric equivalent measurement, as follows: Millimeters (mm) = Inches x 25.4 Centimeters (cm) = Inches x 2.54 Meters (M) = Inches x .0254 T R A H C H T G N E L N O I T C E S T N E V l a n i m o N h t g n e L n o i t c e S ) s e h c n i ( 62 14 26 38 4 T O T A L Q T Y ...

  • Lennox Hearth ELDV-35NE - page 14

    14 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Push the vent component against the previous section until it fully engages, then twist the com ponen t cloc kwise runni ng the dimpl es dow n and along the incline channels until they seat at the end of the channels. This seating position is indicated by the alignment of the arrow and dimple ...

  • Lennox Hearth ELDV-35NE - page 15

    15 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. If the vent system extends more than 5 feet (1.5m) above the roof flashing, stabilizers may be necessar y . Additional screws may be used at section joints for added stability . Guide wires may be attached to the joint for additional sup - port on multiple joint configurations. G. Continue ...

  • Lennox Hearth ELDV-35NE - page 16

    16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. u Ceil in g F ire st op / Spacer (SV4.5VF) v When using Se- cure Flex, use Firestop / Spac- er SF4.5VF A Vent Restrictor , as shown in Figure 16 Page 12 , must be used in this application Figure 25 - T op Vent - STRAIGHT 40 feet (12.2 meters) Maximum VERTICAL VENT FIGURES/T ABLES Notes: ? ...

  • Lennox Hearth ELDV-35NE - page 17

    17 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Maintain a minimum 1" (25 mm) clearance to combustibles on the vertical sections. Clear - ances for the horizontal runs are; 3" (76 mm) on top, 1" (25 mm) on sides, and 1" (25 mm) at the bottom. B. Frame exterior wall opening - Locate the center of the vent outlet on the e ...

  • Lennox Hearth ELDV-35NE - page 18

    18 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Support Brackets Building Support Framing SV4.5E90 Elbow Ceiling Fireplace SV4.5L6/12/24/36/48 Vent Sections Vertical Rise Support Bracket Spacing Every 5 ft (1.52 m) TYPICAL HORIZONT AL VENT INST ALLA TION u W h e n U s i n g Se cu re Fl ex ™, Use Firestop / Spacer SF4.5VF u Firestop / Spa ...

  • Lennox Hearth ELDV-35NE - page 19

    19 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. J. Assemble vent run to exterior wall - If not previously measured, locate the center of the vent at the exterior wall. Prepare an opening as described in Step B and Figure 29 . Assemble the vent system to point where the terminus of the last section is located relative to the exterior surfac ...

  • Lennox Hearth ELDV-35NE - page 20

    20 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. See T able 9 as an aid in venting component selection for a particular range of exterior wall thicknesses. HORIZONT AL VENT FIGURES/T ABLES Notes:     components (rigid vent pipe and terminal) are shown in the Figures;  ? ...

  • Lennox Hearth ELDV-35NE - page 21

    21 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 32 - T op Vent - TWO 90 DEGREE ELBOWS See T able 9 on Page 20 as an aid in venting component selection for a particular range of exterior wall thicknesses. Example: If 20 feet of (H + H 1 ) horizontal vent run is needed, then 4 feet minimum of (V) vertical vent will be required. This t ...

  • Lennox Hearth ELDV-35NE - page 22

    22 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. V H H 1 V 1 Wall Firestop/Spacer (SV4.5HF) Ceiling Firestop/Spacer (SV4.5VF) When using Secure Flex TM , use Firestop/Spacer SF4.5VF. When using Secure Flex, use Firestop/Spacer SF4.5HF. Wall Firestop/Spacer (SV4.5HF) v v u Min. One Foot Vent Section Required v u E L B A TE m u m i n i M Vm u ...

  • Lennox Hearth ELDV-35NE - page 23

    23 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. D. I n s t a l l F i r e s t o p / S p a c e r s a t c ei li ng s a n d w a l l s - When Secure Flex pe netra tes a wall or ceili ng, a firestop / spacer is required: use the SF4.5 VF fire stop / spac er for ceili ngs and the SF4.5 HF fire stop / spa cer for wa lls. Se e the appr opria te ...

  • Lennox Hearth ELDV-35NE - page 24

    24 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Step 4. FIELD WIRING B. Electronic Wiring (See Figure 37 ) – Note: The electronic appliance must be con- nected to the main power supply . 1 . Route a 3-wire 120Vac 60Hz 1ph power supply to the appliance junction box. 2 . Remove the electrical inlet cover plate from the side of the unit by ...

  • Lennox Hearth ELDV-35NE - page 25

    25 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Note: Remote receiver should be located in the wall, or if installed in the control compartment, pulled all the way forward and completely to the left or right against the corner posts. The door must be removed first to place the receiver in the lower control compartment. 7. If wall-mounted ...

  • Lennox Hearth ELDV-35NE - page 26

    26 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 40 Step 6. CONNECTING GAS LINE All codes require a shut-off valve mounted in the supply line. The orientation of the shut-off valve should face the front. Figure 39 illustrates two metho ds for connecting the gas supp ly . A sediment trap is recommended in the gas piping within the hom ...

  • Lennox Hearth ELDV-35NE - page 27

    27 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. T urn on gas supply and test for gas leaks, us- ing a gas leak test solution (also referred to as bubble leak solution). Note: Using a soapy water solution is an effective leak test solution but it is not recom - mended, because the soap residue that is left on th e pip es /fit ti ng s can r ...

  • Lennox Hearth ELDV-35NE - page 28

    28 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. REFERENCE Firebox Accessories / Parts Cat. No. Model No. Description 88L53 FGE Bag of Glowing Embers 80L42 FDVS Bag of Decorative Volcanic Stone Glowing Embers Bag of Glowing Embers (rockwool) Separate into Quarter Size (separate) Pieces Step 8. INST ALL VOLCANIC STONE, GLOWING EMBERS AND LOG ...

  • Lennox Hearth ELDV-35NE - page 29

    29 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. ELDV3530 LOG PLACEMENT Log Number Description 1 Log, Center 2 Log, Rear 3 Log, Front 4 Log, Left 5 Log, Right Catalog Number for the entire log set: H4656 Align holes at the bottom of log (1) over the pins on the burner Align holes at the bottom of log (2) over the pins of the back baffle. A ...

  • Lennox Hearth ELDV-35NE - page 30

    30 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. ELDV4035 LOG PLACEMENT Log Number Description 1 Log, Center 2 Log, Rear 3 Log, Front 4 Log, Left 5 Log, Right Catalog Number for the entire log set: H4657 4 2 5 Align holes at the bottom of log (1) over the pins on the burner 1 Baffle Pins Baffle Burner Step 1 Step 2 Step 3 Step 4 Align hol ...

  • Lennox Hearth ELDV-35NE - page 31

    31 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Log Number Description 1 Log, Center 2 Log, Rear 3 Log, Front 4 Log, Left 5 Log, Right 6 Log, Right/Rear 7 Log, Left/Rear Catalog Number for the entire log set: H4658 ELDV4540 LOG PLACEMENT (REPEA T STEPS 1 THRU 4 FROM ELDV4035 LOG PLACEMENT AND THEN ADD THE FOLLOWING STEPS) 7 2 5 1 3 4 6 Ste ...

  • Lennox Hearth ELDV-35NE - page 32

    32 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Step 9. REMOVING AND INST ALLING THE GLASS DOOR Air Shutter Adjustment Guidelines : Amount of Primary Air Flame Color Air Shutter Adjustment If ai r shu tte r is closed too far Flame will be orange Air shutter gap should be increased If ai r shu tte r is open too far Flame will be blue Air sh ...

  • Lennox Hearth ELDV-35NE - page 33

    33 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. W ARNINGS • Air shutter adjustment should only be performed by a quali- fied professional ser vice tech - nician. • Ensure front glass panel are in place and sealed during adjustment. CAUTIONS • Soot will be produced if the air shutter is closed too much. Any damage due to sooting resu ...

  • Lennox Hearth ELDV-35NE - page 34

    34 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Step 11. HOOD INST ALLA TION The hood is optional for these products. In "Shadow Box" installations, the hood may not be desired. If the opening above the door is objectionable (as is the case in certain "Flush-Mounted" installations) the hood may be used. Position the hoo ...

  • Lennox Hearth ELDV-35NE - page 35

    35 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. STEP 12. A TT ACHING SAFETY -IN-OPERA TION W ARNINGS It is the installer ' s responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance. A PP OS I TI O N D ES M I S ...

  • Lennox Hearth ELDV-35NE - page 36

    36 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Cat. No. Model Description 77L70 SV4.5L6 6 In ch ( 15 2 mm ) 77L71 SV4.5L12 12 I nch ( 30 5 mm ) 77L72 SV4.5L24 24 I nch ( 61 0 mm ) 77L73 SV4.5L36 36 I nch ( 91 4 mm ) 77L74 SV4.5L48 48 I nch ( 12 19 m m) 77L75 SV4.5LA T elescopic Length Slip Sec - tion (2" to 7-1/2" rigid) 77L76 S ...

  • Lennox Hearth ELDV-35NE - page 37

    37 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Cat. # Model Description H1969 SF4.5HT -2 Horizontal Square T ermina - tion for flex (without flex) 77L87 SFKIT12S Square T erm. for flex ( w i t h 12 i n c h [ 3 0 5 m m ] * compressed flex) 77L88 SFKIT18S Square T erm. for flex ( w i t h 18 i n c h [ 4 5 7 m m ] * compressed flex) 77L ...

  • Lennox Hearth ELDV-35NE - page 38

    38 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Millivolt SIT Systems Propane Gas to Natural Gas Conversion Kits Models Catalog No. ELDV-35 H3960 ELDV-40 H7252 ELDV-45 H7254 Millivolt SIT Systems Natural Gas T o Propane Gas Conversion Kits Models Catalog No. ELDV-35 85L62 ELDV-40 H7257 ELDV-45 H7253 Electronic DEXEN Systems Propane Gas T o ...

  • Lennox Hearth ELDV-35NE - page 39

    39 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 55 Millivolt Appliances Step 5. SIT Systems - Refer to Figure 56 and the instructions provided with the kit. Using a T orx T20 (with 1/4" shank and center hole), remove and discard the three pressur e regulator mounting screws. Remove the pressure regu- lator , spring, poppet, dia ...

  • Lennox Hearth ELDV-35NE - page 40

    Printed in U.S.A. © 2006 Lennox Hearth Products P/N 850036M REV . H 01/2011 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. 1508ElmHillPik ...

メーカー Lennox Hearth カテゴリー Indoor Fireplace

Lennox Hearth ELDV-35NEのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- ELDV-35NEの取扱説明書
- Lennox Hearthの製品カード
- パンフレット
- またはLennox Hearth ELDV-35NEの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Lennox Hearth ELDV-35NEの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Lennox Hearth ELDV-35NEの取り付け説明書、サービスマニュアル、簡易説明書、またはLennox Hearth ELDV-35NEのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Lennox Hearth ELDV-35NEの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Lennox Hearth ELDV-35NEデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLennox Hearth ELDV-35NEを使用するのを助ける技術的文書のことです。説明書は通常、全てのLennox Hearth ELDV-35NEユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Lennox Hearthの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Lennox Hearth ELDV-35NEの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLennox Hearth ELDV-35NEの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Lennox Hearth ELDV-35NEに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Lennox Hearth ELDV-35NEデバイスの基本機能を使うにあたってのヒント。 Lennox Hearth ELDV-35NEのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Lennox Hearth ELDV-35NEに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLennox Hearth ELDV-35NEのメーカー/サービスへの連絡先に関する情報。

Lennox Hearth ELDV-35NEについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLennox Hearth ELDV-35NEの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLennox Hearth ELDV-35NEで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)