  • Generac 4582 - page 1

    Owner’ s Manual • SAFETY • ASSEMBLY • OPERATION • TROUBLESHOOTING • ELECTRICAL DATA • PARTS • WARRANTY 1-800-333-1322 UL TRA SOURCE Portable Generator COMMERCIAL • INDUSTRIAL • RESIDENTIAL MODELS: 004 4 51 (12,500 W A TT) 004582 (15,000 W A TT) AUTHORIZED DEALER SUPPORT: GENERAC POWER SYSTEMS, INC. P.O. Box 297 • Whitewater, W ...

  • Generac 4582 - page 2

    Table of Contents Commercial-Industrial-Residential Portable Generator System Safety Rules ..............................................1-3 Section 1 – General Information ................4 1.1 Unpacking ....................................................................4 1.1.1 Accessory Box ..................................................4 1 ...

  • Generac 4582 - page 3

    INTRODUCTION Thank you for purchasing this model of the GUARDIAN ® product line by Generac Power Systems, Inc. This model is a compact, high performance, air-cooled, engine driven generator designed to supply electrical power to operate electrical loads where no utility power is available. READ THIS MANUAL THOROUGHLY If you do not understand any p ...

  • Generac 4582 - page 4

    2 • Never start or stop the unit with electrical loads connected to receptacles AND with connected devices turned ON. Start the engine and let it stabilize before connecting electrical loads. Disconnect all electrical loads before shutting down the generator. • Do not insert objects through unit's cooling slots. • Never operate generator ...

  • Generac 4582 - page 5

    3  ELECTRICAL HAZARDS  • All generators covered by this manual produce dangerous electrical voltages and can cause fatal electrical shock. Utility power delivers extremely high and dangerous voltages as does the generator when it is in operation. Avoid contact with bare wires, terminals, connections, etc., while the unit is running. Ensure ...

  • Generac 4582 - page 6

    1.1 UNPACKING • Set the palleted carton on a rigid flat surface. • Remove staples along bottom of carton that fasten carton to pallet. Open carton from top. • Remove all packaging material. • Remove separate accessory box. • Lift carton off the generator. • Remove generator from shipping pallet by removing bolts through the shipping bra ...

  • Generac 4582 - page 7

    5 1.2.3 BATTERY CONNECTION • The battery shipped with the generator has been provided fully charged. Caution must be taken when connecting the battery. • Cut the tie wrap cable holding the RED and BLACK battery cables to the stator. • Connect the RED battery cable to the battery Positive terminal (+). After making sure that the connection is ...

  • Generac 4582 - page 8

    ITEM PART NO. QTY. DESCRIPTION 1 087968 1 SWITCH, ROCKER -/0 2 090418 1 OUTLET, 12VDC SNAP 3 0D6640 1 COVER, GOVERNOR CONTROL 4 090987 6 SCREW PPHM M3-0.5 X 12 5 0D2502 1 PANEL, SHEET METAL 6 068868 2 OUTLET 30A 120V RECEPT 7 022985 2 WASHER FLAT #6 8 043182 10 WASHER LOCK M3 9 051714 6 NUT HEX M3-0.5 G8 10 075207A 4 CIRCUIT BREAKER 30A 11 075207 2 ...

  • Generac 4582 - page 9

    30 Section 7 — Exploded Views and Parts Lists Commercial-Industrial-Residential Portable Generator System Control Panel – Drawing No. 0E0227B 2.2 CORD SETS AND CONNECTION PLUGS 2.2.1 AC, 20 AMP, DUPLEX RECEPTACLE This is a 120 Volt outlet protected against overload by a 20 Amp push-to-reset circuit breaker. Use each socket to power 120 Volt AC, ...

  • Generac 4582 - page 10

    Figure 9 - 120 VAC, 30 Amp Receptacle Use this receptacle to operate 120 Volt AC, 60 Hz, single phase loads requiring up to 3600 watts (3.6 kW) of power at 30 Amps. The outlet is protected by a 30 Amp push-to-reset circuit breaker. 2.2.4 120/240V AC, 30 AMP RECEPTACLE Use a NEMA L14-30 plug with this receptacle. Connect a suitable 4-wire grounded c ...

  • Generac 4582 - page 11

    2.3 HOW TO USE THE GENERATOR If you have any problems operating your generator, please call the generator helpline at 1-800-333-1322. 2.3.1 GROUNDING THE GENERATOR The National Electrical Code requires that the frame and external electrically conductive parts of this generator be properly connected to an approved earth ground . Local electrical cod ...

  • Generac 4582 - page 12

    10 2.5 WATTAGE REFERENCE GUIDE Device . . . . . . . . . . . . . . . . . . . . . . .Running Watts *Air Conditioner (12,000 Btu) . . . . . . . . . . . . . . . . .1700 *Air Conditioner (24,000 Btu) . . . . . . . . . . . . . . . . .3800 *Air Conditioner (40,000 Btu) . . . . . . . . . . . . . . . . .6000 Battery Charger (20 Amp) . . . . . . . . . . . . ...

  • Generac 4582 - page 13

    11 2.6.2 ADDING GASOLINE  WARNING: Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot. DO NOT light a cigarette or smoke when filling the fuel tank.  Caution: Do not overfill the fuel tank. Always leave room for fuel expansion. • Use regular UNLEADED gasoline with the generator engine. Do not use premium gasoli ...

  • Generac 4582 - page 14

    12 • Move engine CHOKE knob to “Full Choke” position. Figure 17 - Full Choke Position • To start engine, press and hold the Start/Run/Stop switch in the “Start” position. The engine will crank and attempt to start. When the engine starts, release the switch to the run position. • When the engine starts, move choke knob to “1/2 Choke ...

  • Generac 4582 - page 15

    2.12 CHARGING A BATTERY  DANGER! Storage batteries give off explosive hydrogen gas while recharging. An explosive mixture will remain around the battery for a long time after it has been charged. The slightest spark can ignite the hydrogen and cause an explosion. Such an explosion can shatter the battery and cause blindness or other serious inju ...

  • Generac 4582 - page 16

    3.2.1 GENERATOR SPECIFICATIONS MODEL GPS 12500 GPS 15000 Model # 004451-1 004582-1 Rated Max. Power 12.5 kW 15.0 kW Surge Power 18.75 kW 22.5 kW Rated AC Voltage 120/240 120/240 Rated Max AC Load Current @ 240V 52.0 Amps 62.5 Amps Current @ 120V 104.0 Amps 125.0 Amps Rated Frequency 60 Hz @ 3600 RPM Phase Single Phase Rated DC Voltage 12 Volts Rate ...

  • Generac 4582 - page 17

    15 3.3 GENERAL RECOMMENDATIONS The warranty of the generator does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain the generator as instructed in this manual. Some adjustments will need to be made periodically to properly maintain the generator. All adjustm ...

  • Generac 4582 - page 18

    16 3.3.6 REPLACING THE SPARK PLUG Use Champion RC14YC spark plug or equivalent. The correct air gap is 0.76 mm (0.030 in.). Replace the plug once each year . This will help your engine start easier and run better. 1. Stop the engine and pull the spark plug wire off of the spark plug. 2. Clean the area around the spark plug and remove it from the cy ...

  • Generac 4582 - page 19

    Figure 21 - Spark Arrestor 3.6 ADJUSTING VALVE CLEARANCE After the first 50 hours of operation, you should adjust the valve clearance in the engine. Important: If you feel uncomfortable about doing this procedure or you don't have the proper tools, please take your generator in to the nearest service center to have the valve clearance adjusted ...

  • Generac 4582 - page 20

    18 Section 3 — Maintenance Commercial-Industrial-Residential Portable Generator System 3.7 GENERAL The generator should be started at least once every seven days and be allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following information as a guide to prepare it for storage. ? ...

  • Generac 4582 - page 21

    18 Section 3 — Maintenance Commercial-Industrial-Residential Portable Generator System 3.7 GENERAL The generator should be started at least once every seven days and be allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following information as a guide to prepare it for storage. ? ...

  • Generac 4582 - page 22

    Figure 21 - Spark Arrestor 3.6 ADJUSTING VALVE CLEARANCE After the first 50 hours of operation, you should adjust the valve clearance in the engine. Important: If you feel uncomfortable about doing this procedure or you don't have the proper tools, please take your generator in to the nearest service center to have the valve clearance adjusted ...

  • Generac 4582 - page 23

    16 3.3.6 REPLACING THE SPARK PLUG Use Champion RC14YC spark plug or equivalent. The correct air gap is 0.76 mm (0.030 in.). Replace the plug once each year . This will help your engine start easier and run better. 1. Stop the engine and pull the spark plug wire off of the spark plug. 2. Clean the area around the spark plug and remove it from the cy ...

  • Generac 4582 - page 24

    15 3.3 GENERAL RECOMMENDATIONS The warranty of the generator does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain the generator as instructed in this manual. Some adjustments will need to be made periodically to properly maintain the generator. All adjustm ...

  • Generac 4582 - page 25

    3.2.1 GENERATOR SPECIFICATIONS MODEL GPS 12500 GPS 15000 Model # 004451-1 004582-1 Rated Max. Power 12.5 kW 15.0 kW Surge Power 18.75 kW 22.5 kW Rated AC Voltage 120/240 120/240 Rated Max AC Load Current @ 240V 52.0 Amps 62.5 Amps Current @ 120V 104.0 Amps 125.0 Amps Rated Frequency 60 Hz @ 3600 RPM Phase Single Phase Rated DC Voltage 12 Volts Rate ...

  • Generac 4582 - page 26

    2.12 CHARGING A BATTERY  DANGER! Storage batteries give off explosive hydrogen gas while recharging. An explosive mixture will remain around the battery for a long time after it has been charged. The slightest spark can ignite the hydrogen and cause an explosion. Such an explosion can shatter the battery and cause blindness or other serious inju ...

  • Generac 4582 - page 27

    12 • Move engine CHOKE knob to “Full Choke” position. Figure 17 - Full Choke Position • To start engine, press and hold the Start/Run/Stop switch in the “Start” position. The engine will crank and attempt to start. When the engine starts, release the switch to the run position. • When the engine starts, move choke knob to “1/2 Choke ...

  • Generac 4582 - page 28

    11 2.6.2 ADDING GASOLINE  WARNING: Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot. DO NOT light a cigarette or smoke when filling the fuel tank.  Caution: Do not overfill the fuel tank. Always leave room for fuel expansion. • Use regular UNLEADED gasoline with the generator engine. Do not use premium gasoli ...

  • Generac 4582 - page 29

    10 2.5 WATTAGE REFERENCE GUIDE Device . . . . . . . . . . . . . . . . . . . . . . .Running Watts *Air Conditioner (12,000 Btu) . . . . . . . . . . . . . . . . .1700 *Air Conditioner (24,000 Btu) . . . . . . . . . . . . . . . . .3800 *Air Conditioner (40,000 Btu) . . . . . . . . . . . . . . . . .6000 Battery Charger (20 Amp) . . . . . . . . . . . . ...

  • Generac 4582 - page 30

    2.3 HOW TO USE THE GENERATOR If you have any problems operating your generator, please call the generator helpline at 1-800-333-1322. 2.3.1 GROUNDING THE GENERATOR The National Electrical Code requires that the frame and external electrically conductive parts of this generator be properly connected to an approved earth ground . Local electrical cod ...

  • Generac 4582 - page 31

    Figure 9 - 120 VAC, 30 Amp Receptacle Use this receptacle to operate 120 Volt AC, 60 Hz, single phase loads requiring up to 3600 watts (3.6 kW) of power at 30 Amps. The outlet is protected by a 30 Amp push-to-reset circuit breaker. 2.2.4 120/240V AC, 30 AMP RECEPTACLE Use a NEMA L14-30 plug with this receptacle. Connect a suitable 4-wire grounded c ...

  • Generac 4582 - page 32

    30 Section 7 — Exploded Views and Parts Lists Commercial-Industrial-Residential Portable Generator System Control Panel – Drawing No. 0E0227B 2.2 CORD SETS AND CONNECTION PLUGS 2.2.1 AC, 20 AMP, DUPLEX RECEPTACLE This is a 120 Volt outlet protected against overload by a 20 Amp push-to-reset circuit breaker. Use each socket to power 120 Volt AC, ...

  • Generac 4582 - page 33

    ITEM PART NO. QTY. DESCRIPTION 1 087968 1 SWITCH, ROCKER -/0 2 090418 1 OUTLET, 12VDC SNAP 3 0D6640 1 COVER, GOVERNOR CONTROL 4 090987 6 SCREW PPHM M3-0.5 X 12 5 0D2502 1 PANEL, SHEET METAL 6 068868 2 OUTLET 30A 120V RECEPT 7 022985 2 WASHER FLAT #6 8 043182 10 WASHER LOCK M3 9 051714 6 NUT HEX M3-0.5 G8 10 075207A 4 CIRCUIT BREAKER 30A 11 075207 2 ...

  • Generac 4582 - page 34

    5 1.2.3 BATTERY CONNECTION • The battery shipped with the generator has been provided fully charged. Caution must be taken when connecting the battery. • Cut the tie wrap cable holding the RED and BLACK battery cables to the stator. • Connect the RED battery cable to the battery Positive terminal (+). After making sure that the connection is ...

  • Generac 4582 - page 35

    1.1 UNPACKING • Set the palleted carton on a rigid flat surface. • Remove staples along bottom of carton that fasten carton to pallet. Open carton from top. • Remove all packaging material. • Remove separate accessory box. • Lift carton off the generator. • Remove generator from shipping pallet by removing bolts through the shipping bra ...

  • Generac 4582 - page 36

    3  ELECTRICAL HAZARDS  • All generators covered by this manual produce dangerous electrical voltages and can cause fatal electrical shock. Utility power delivers extremely high and dangerous voltages as does the generator when it is in operation. Avoid contact with bare wires, terminals, connections, etc., while the unit is running. Ensure ...

  • Generac 4582 - page 37

    2 • Never start or stop the unit with electrical loads connected to receptacles AND with connected devices turned ON. Start the engine and let it stabilize before connecting electrical loads. Disconnect all electrical loads before shutting down the generator. • Do not insert objects through unit's cooling slots. • Never operate generator ...

  • Generac 4582 - page 38

    INTRODUCTION Thank you for purchasing this model of the GUARDIAN ® product line by Generac Power Systems, Inc. This model is a compact, high performance, air-cooled, engine driven generator designed to supply electrical power to operate electrical loads where no utility power is available. READ THIS MANUAL THOROUGHLY If you do not understand any p ...

  • Generac 4582 - page 39

    Owner’ s Manual • SAFETY • ASSEMBLY • OPERATION • TROUBLESHOOTING • ELECTRICAL DATA • PARTS • WARRANTY 1-800-333-1322 UL TRA SOURCE Portable Generator COMMERCIAL • INDUSTRIAL • RESIDENTIAL MODELS: 004 4 51 (12,500 W A TT) 004582 (15,000 W A TT) AUTHORIZED DEALER SUPPORT: GENERAC POWER SYSTEMS, INC. P.O. Box 297 • Whitewater, W ...

  • Generac 4582 - page 40

    Owner’ s Manual • SAFETY • ASSEMBLY • OPERATION • TROUBLESHOOTING • ELECTRICAL DATA • PARTS • WARRANTY 1-800-333-1322 UL TRA SOURCE Portable Generator COMMERCIAL • INDUSTRIAL • RESIDENTIAL MODELS: 004 4 51 (12,500 W A TT) 004582 (15,000 W A TT) AUTHORIZED DEALER SUPPORT: ...

メーカー Generac カテゴリー Portable Generator

Generac 4582のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 4582の取扱説明書
- Generacの製品カード
- パンフレット
- またはGenerac 4582の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Generac 4582の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Generac 4582の取り付け説明書、サービスマニュアル、簡易説明書、またはGenerac 4582のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Generac 4582の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Generac 4582デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGenerac 4582を使用するのを助ける技術的文書のことです。説明書は通常、全てのGenerac 4582ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Generacの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Generac 4582の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGenerac 4582の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Generac 4582に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Generac 4582デバイスの基本機能を使うにあたってのヒント。 Generac 4582のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Generac 4582に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGenerac 4582のメーカー/サービスへの連絡先に関する情報。

Generac 4582についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGenerac 4582の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGenerac 4582で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)