  • Liebert II - page 1

    P OWER P ROTECTION Interceptor II T ransi ent V olta ge Surge Su ppress or Installatio n, Operation & Maintenance Manual ...

  • Liebert II - page 2

    ...

  • Liebert II - page 3

    i T ABLE OF CONTENTS 1.0 I NTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2.0 U NPACKING AND I NS TALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2.1 Unpa ckin g and Prel imina ry Insp ection . . . . . . . . . . . . . . . . ...

  • Liebert II - page 4

    ii FIGURES Figure 1 Typical cabi net data, Form C contact and wiri ng . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Figure 2 Typical parallel connections (without internal rotary disconnect) . . . . . . . . . . . . . . . . . . . . . . . 6 Figure 3 Typical parallel connections (with internal rotary disconnect) . . . . . . ...

  • Liebert II - page 5

    Introduc tion 1 1.0 I NTRODUCTION The L iebert Inter ceptor I I Seri es Tr ansient Voltag e Surg e Supp ressor (TVSS ) is a h igh-q uality, high energy surge current divers ion syst em designed to pro tect sensit ive equipment from damag- ing tra nsient voltag e surges. Pr oper install ation is required f or maximum syst em performance. The ins tal ...

  • Liebert II - page 6

    2 Un packing and Insta llation 2.0 U NPACKING AN D I NSTALLATION 2.1 Unpacking and Prelimi nary Inspection 1. Inspect th e shipping crate(s ) for damage or signs of mishandling befo re unpacking the unit . 2. Remove any securin g bands and cardboard pa cking and ins pect the un it for any o bvious shipping da mages. 3. If any damage as a re sult of ...

  • Liebert II - page 7

    Unpacki ng and Ins tallatio n 3 Figure 1 T ypical cabinet data, Form C contact and wiring T able 1 Units with or without internal service disconnect switch **Mo del Ser ies Applicatio n Connec tion Dime nsions (Inch es) Weig ht (lbs.) A B C D E F SI016 SI025 All volt age configu rations* Wire Lugs 16 12 9 16.75 10 0.31 35 Discon nect (optiona l) 16 ...

  • Liebert II - page 8

    4 El ectrical Connections 3.0 E LECTRICAL C ONNE CTIO NS All electri cal connect ions shoul d be inst alled only by a qualifie d (license d) electri cian. All w iring must com ply with the Nationa l Electrical C ode (NEC) and applicab le local codes. 3.1 V oltage Ratings and Power Source Configurations Before making conne ctions to the unit, verify ...

  • Liebert II - page 9

    Electrical Con nections 5 Disconnect Switch —T VSS un its mu st be co nnect ed to th e load side o f the m ain serv ice dis con- nect, or load side of a protected circuit’s disconnect ing means. Interceptor II “ SI” Models with a n “R” designat or in the part n umber, are equipped w ith an inter- nal disconnect switch, that can be us ed ...

  • Liebert II - page 10

    6 El ectrical Connections Figure 2 T ypical parallel connections (without internal rot ary disconnect) Figure 3 T ypical parallel connections (with inte rnal rotary disconnect) Phases Neut ral Grou nd Lieb ert Surge Pr otective Prot ected Pane l To Loads Prot ected Wir e shou ld be les s than 5 feet and str aight as possible Devi ce Phases Neutral ...

  • Liebert II - page 11

    Electrical Con nections 7 3.2.1 System Grounding and Bonding The performa nce and safety of any TVSS sy stem is depende nt on proper ground ing and bonding. Ground ing is required prima rily for safety . Correct implemen tation als o enhances e quipment per- formance. Incorrect grounding can reduc e or impede the TVSS's operation. All electric ...

  • Liebert II - page 12

    8 O peration 4.0 O PERATION Figure 4 Operation contro ls and indicators Status LED Indicat ors —Green and re d LEDs for each protect ed phase pro vide a visual status summary of all surge modules within device. Full Protection LEDs —Green LED s are illumi nated onl y when all surge compo nents ar e at 100% percent efficiency. Reduc ed Protecti ...

  • Liebert II - page 13

    Operatio n 9 Form C Dry Cont acts —Dual summary alarm Form C (1 N.O. and 1 N.C.) relay cont acts are provided for remote indication of each f ailed surge current modules. The summary alarm contacts terminals a re loca ted on th e PC board i nside the u nit. Contacts are rate d for 5 amps a t 240 VAC with a po wer factor of 1.0 . The states of the ...

  • Liebert II - page 14

    10 T roubleshooting, Service & Maintenan ce 5.0 T RO UBLESHOOTIN G , S ERVICE & M AINTE NANCE 5.1 T roubles hooting If status failure indication occurs or Form C relay has changed states, a qualified electrician should fi rst determi ne if the s ystems vol tage an d proper phasi ng exists . If the Interceptor II TVSS remains in an alarm con ...

  • Liebert II - page 15

    Limited W arranty 1 1 6.0 L IMITED W AR RANT Y This Warranty is given ON LY to purchasers who buy for commercial or industrial use in the ordi- nary course of each purchaser's business. General: Lieb ert’s pro ducts are in our opin ion the f inest av ailable. W e take p ride in our prod ucts and are pleased that you have chosen t hem. Under ...

  • Liebert II - page 16

    12 Limited W arranty Items Not Covered By Warranty: THIS WARRANTY DOES NOT COVER DAMAGE OR DEFECT CAUSED BY misu se, improper applica tion, wrong or inadeq uate electrica l current or connect ion, inadequate wa ter or drain ser- vices, negligence, inappropriate on site operating cond itions, corrosive atmosphere, repair by non- Liebert designate d ...

  • Liebert II - page 17

    Revise d: April 20 01 Interceptor T ransi ent V oltage Surge Suppres sor The Company Behind the Produc ts With more than 1,000,0 00 installati ons arou nd the glo be, Liebert is the world leade r in computer prot ection s ystems . Since its foun ding in 196 5, Lieb ert has d evelo ped a comp lete ran ge of su pport and prote ction systems for sensi ...

メーカー Liebert カテゴリー Surge Protector

Liebert IIのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- IIの取扱説明書
- Liebertの製品カード
- パンフレット
- またはLiebert IIの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Liebert IIの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Liebert IIの取り付け説明書、サービスマニュアル、簡易説明書、またはLiebert IIのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Liebert IIの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Liebert IIデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLiebert IIを使用するのを助ける技術的文書のことです。説明書は通常、全てのLiebert IIユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Liebertの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Liebert IIの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLiebert IIの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Liebert IIに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Liebert IIデバイスの基本機能を使うにあたってのヒント。 Liebert IIのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Liebert IIに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLiebert IIのメーカー/サービスへの連絡先に関する情報。

Liebert IIについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLiebert IIの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLiebert IIで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)