Desa PCVDR24 RGAの取扱説明書

20ページ 2.1 mb
ダウンロード

ページに移動 of 20

Summary
  • Desa PCVDR24 RGA - page 1

    NA TURAL GAS LOG WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS • Do not try to light ...

  • Desa PCVDR24 RGA - page 2

    2 901747 VENTED NA TURAL GAS LOGS 1. This appliance, as supplied, is only for use with the type of gas indicated on the rating plate. This appliance is con- vertible for use with propane/LP , using the GA9050 or GA9150 pilot kit. SAFETY INFORMA TION Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headach ...

  • Desa PCVDR24 RGA - page 3

    3 901747 OWNER’S MANUAL PRODUCT IDENTIFICA TION Figure 1 - Product Identification OPTIONAL PRODUCT FEA TURES ON/OFF SAFETY VALVE/ PILOT KIT AND PROPANE/LP CONVERSION An optional valve/safety pilot kit with a piezo ignitor is available for this appliance. This system requires no matches, batteries, or other sources to light. You must use this opti ...

  • Desa PCVDR24 RGA - page 4

    4 901747 VENTED NA TURAL GAS LOGS PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation . All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually T ight Construction 2. Unconfined Space 3. Confined Space ...

  • Desa PCVDR24 RGA - page 5

    5 901747 OWNER’S MANUAL DETERMINING FRESH-AIR FLOW FOR APPLIANCE LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install appliance plus any adjoining rooms with doorless passageways or ventilation grills between ...

  • Desa PCVDR24 RGA - page 6

    6 901747 VENTED NA TURAL GAS LOGS AIR FOR COMBUSTION AND VENTILA TION Continued Figure 3 - Ventilation Air from Outdoors Figure 2 - Ventilation Air from Inside Building Outlet Air Ventilated Attic Outlet Air Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Or Remove Door into Adjoining Room, Option 3 Ventilation Grills Into Adjoin ...

  • Desa PCVDR24 RGA - page 7

    7 901747 OWNER’S MANUAL INST ALLA TION WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a quali- fied chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and dis- tribute soot within the house. In- spect chimne ...

  • Desa PCVDR24 RGA - page 8

    8 901747 VENTED NA TURAL GAS LOGS INST ALLA TION Continued WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once. WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once. CHECKING ...

  • Desa PCVDR24 RGA - page 9

    9 901747 OWNER’S MANUAL INST ALLA TION Continued Figure 7 - Checking Gas Joints HEARTH KIT ASSEMBLY AND INSTALLATION Kit Assembly Note: Be sure all pipe threaded connections are tight, and have thread compound to pre- vent leaks. 1. Determine which side the gas line will be coming into the fir eplace. 2. Using a hammer and screw dri ver , re- mov ...

  • Desa PCVDR24 RGA - page 10

    10 901747 VENTED NA TURAL GAS LOGS 2. Attach the pilot gas line to the pilot out- let of the gas control v alve and tighten. Connect the thermocouple to the rear of the gas control valv e. See Figure 12. Do not overtighten. If using propane/LP g as, see Changing Pilot Orif ice, page 11. 3. Install the inlet fitting into the inlet opening of the gas ...

  • Desa PCVDR24 RGA - page 11

    11 901747 OWNER’S MANUAL TESTING BURNER FOR LEAKS 1. Generously apply soapy solution to all connections. WARNING: Never check for gas leaks with open flame. 2. Light the b urner with the shut-off v alve no more than half open and holding a match slightly in front of the pan (see Lighting Instructions, page 12). 3. Inspect all connections for bubb ...

  • Desa PCVDR24 RGA - page 12

    12 901747 VENTED NA TURAL GAS LOGS LIGHTING INSTRUCTIONS OPERA TING APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next t ...

  • Desa PCVDR24 RGA - page 13

    13 901747 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off log set and let cool before servicing. Only a qualified service person should service and repair log set. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit. POSSIBLE CAUSE REMEDY OBSERVED PROBLEM Continued Note: For additional help, v ...

  • Desa PCVDR24 RGA - page 14

    14 901747 VENTED NA TURAL GAS LOGS OBSERVED PROBLEM When ignitor button is pressed, there is no spark at pilot (GA9050 Only) When ignitor button is pressed, there is spark at pilot but no ignition (GA9050 Only) Pilot lights but flame goes out when control knob is released (GA9050 Only) Burner does not light after pilot is lit (GA9050 Only) Delayed ...

  • Desa PCVDR24 RGA - page 15

    15 901747 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot re ...

  • Desa PCVDR24 RGA - page 16

    16 901747 VENTED NA TURAL GAS LOGS ILLUSTRA TED PA R T S BREAKDOWN MODEL PCVDR24 3 13 1 8 6 4 2 10 7 20 5 9 9 14 15 19 16 21 17 18 11 12 ...

  • Desa PCVDR24 RGA - page 17

    17 901747 OWNER’S MANUAL P ARTS LIST This list contains replaceable parts used in your log set. When ordering parts, follow the instructions listed under Replacement Parts on page 18 of this manual. MODEL PCVDR24 KEY PART NO. NUMBER DESCRIPTION QTY. 1 901058-01 Brass 3/8 FLR x 1/2 FPT Adapter 1 2 901059-01 Brass 3/8 FLR x 3/8 FPT Adapter 1 3 9010 ...

  • Desa PCVDR24 RGA - page 18

    18 901747 VENTED NA TURAL GAS LOGS ACCESSORIES Purchase these logset accessories from your local dealer. If they can not supply these accessories, call DESA International’s Sales Department at 1-800-432-2382 for infor- mation. You can also write to the address listed on the back page of this manual. MANUAL SHUTOFF VALVE GA5010 For all models. Man ...

  • Desa PCVDR24 RGA - page 19

    19 901747 OWNER’S MANUAL Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514 1-800-397-7553 203-248-7553 Parts Department Portable Heater Parts 342 N. County Rd. 400 E. Valparaiso, IN 46383 All States 219-462-7441 1-800-362-6951 Parts Department FBD 1349 Adams St. Bowling Green, KY 42103 502-846-1199 1-800-654-8534 Fax: 1-800-846-0090 Four Fl ...

  • Desa PCVDR24 RGA - page 20

    LIMITED WARRANTY COMFORT FLAME ® VENTED GAS LOGS DESA International warrants this product to be free from defects on burner system for three (3 ) years and logs for a lifetime f rom the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a cl ...

メーカー Desa カテゴリー Water Heater

Desa PCVDR24 RGAのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- PCVDR24 RGAの取扱説明書
- Desaの製品カード
- パンフレット
- またはDesa PCVDR24 RGAの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Desa PCVDR24 RGAの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Desa PCVDR24 RGAの取り付け説明書、サービスマニュアル、簡易説明書、またはDesa PCVDR24 RGAのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Desa PCVDR24 RGAの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Desa PCVDR24 RGAデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがDesa PCVDR24 RGAを使用するのを助ける技術的文書のことです。説明書は通常、全てのDesa PCVDR24 RGAユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Desaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Desa PCVDR24 RGAの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははDesa PCVDR24 RGAの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Desa PCVDR24 RGAに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Desa PCVDR24 RGAデバイスの基本機能を使うにあたってのヒント。 Desa PCVDR24 RGAのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Desa PCVDR24 RGAに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるDesa PCVDR24 RGAのメーカー/サービスへの連絡先に関する情報。

Desa PCVDR24 RGAについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもDesa PCVDR24 RGAの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがDesa PCVDR24 RGAで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)