  • Eaton PVE12 - page 1

    M-2854-S Released 8/1/90 Overhaul Manual PVE V ariable Pump 12–21 USgpm capacity at 1800 rpm Vickers ® Piston Pumps ...

  • Eaton PVE12 - page 2

    2 T able of Contents Section Page I. Introduction 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A. Purpose of Manual 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Eaton PVE12 - page 3

    3 Section I – Introduction A. Purpose Of Manual This manual describes operational characteristics and overhaul information for the PVE12, 19(*) and the PVE21(*) – ** variable displacement piston pumps. The information contained herein pertains to the latest design series as listed in T able 1. B. General Information 1. Related Publications - Se ...

  • Eaton PVE12 - page 4

    4 C-10 – CG-10 – CV -10 – CVP-12 – CVPC-12 – Pressure compensated (PVE19, 250-3000 psi) (PVE21, 250-2700 psi) Remote control pressure compensator adjustable from 350-3000 psi using and external relief valve. Load sensing PVE19/21 Load sensing (160 psid) with pressure compensation PVE 19/21 Load sensing (350 psid) with pressure compensatio ...

  • Eaton PVE12 - page 5

    5 Figure 1. Sectional Views of the PVE Pumps Drive Shaft PVE19 Section View PVE12 Section View Housing Rotating Group T apered Roller Bearing Y oke W afer Plate Compensator Y oke Housing Compensator V alve Block Shaft Seal Shaft Bearing Piston ...

  • Eaton PVE12 - page 6

    6 Section II – Description A. General Assembly of a typical pump package is shown in Figure 1. Six types of compensator subassemblies are used with the PVE series pumps. Refer to Section III for principles of operation. See Model Code for pressure settings. 1. Compensator (C), (Flat Cut-Off T ype): A pump using this compensator will maintain a co ...

  • Eaton PVE12 - page 7

    7 Section III – Principles of Operation A. Piston Pump Rotation of the pump drive shaft causes the cylinder block, shoe plate and pistons to rotate. See Figure 2. The piston shoes are held against the yoke face by the shoe plate. The angle of the yoke face imparts a reciprocating motion to each piston within the cylinder block. Inlet and outlet p ...

  • Eaton PVE12 - page 8

    8 Figure 3. Flat Cut-Off Compensator Compensator Spring Drain Pump Load Cross Hole (Open to Spring Area) Compensator Spool Y oke Stroking Piston Rotating Group Y oke Spring Inlet Outlet D. Compensator (Load Sensing T ype - “ CV ” ) Application A frequent application of pressure compensator pumps is to supply sevo valves or mechanically operated ...

  • Eaton PVE12 - page 9

    9 Figure 4. Load Sensing Compensator (CV). Compensator Spring Drain Compensator Spool Y oke Stroking Piston Rotating Group Y oke Spring Inlet Outlet Actuator Load External V alve Spool Orifice ( n P-Pressure Drop) Relief V alve Circuit Operation At Minimum Pressure Refer to Figure 4 during the following description. Assume a no load condition. The ...

  • Eaton PVE12 - page 10

    10 External V alve Spool Orifice Size Increased If the external valve spool orifice size is increased, pump outlet pressure will decrease, lowering force against the compensator spool. (See Figure 4.) The compensator spring causes the spool to move, opening the yoke stroking piston to case drain. As fluid is metered from the yoke stroking piston, t ...

  • Eaton PVE12 - page 11

    11 Figure 5. Load Sensing Pressure Limiting Compensator (CVP , CVPC, CVPD) Compensator Spring Drain Compensator Spool Y oke Stroking Piston Rotating Group Y oke Spring Inlet Outlet Actuator Load External V alve Spool Orifice Load Sensing Spool Set Screw ...

  • Eaton PVE12 - page 12

    12 Section IV – Installation and Operating Instructions A. Installation Drawings The installation drawing listed in T able 2 will show installation dimensions and port locations. B. Mounting and Drive Connections CAUTION Pump shafts are designed to be installed in couplings with a slip fit. Pounding can injure the bearings. Shaft tolerances are s ...

  • Eaton PVE12 - page 13

    13 Sound Level Noise is only indirectly affected by the fluid selection, but the condition of the fluid is of paramount importance in obtaining optimum reduction of system sound levels. Some of the major factors affecting the fluid conditions that cause the loudest noises in a hydraulic system are: 1. V ery high viscosities at start-up temperatures ...

  • Eaton PVE12 - page 14

    14 Section V – Service and Maintenance A. Service T ools The following standard tools for overhauling the piston pump are shown in Figure 8. Standard T ools and Equipment: 1. T orque wrench with short extension and sockets 2. 1 ” micrometer 3. 1 ” depth micrometer 4. External T ruarc pliers 5. Internal T ruarc pliers In addition to the above ...

  • Eaton PVE12 - page 15

    15 Figure 8. Standard T ools. 1 2 3 4 5 6 Figure 9. Special Shaft Bearing Removal and Installation T ools. 1.232 1.500 “ A ” Use for “ A ” Intermediate shaft bearing installation Drive shaft bearing installation Drive shaft bearing removal 4 ” 6 ” 9 ” 1 1/2 ” heavy wall tubing .005 .005 Description A B C V alve Block 1.675 1.300 1.2 ...

  • Eaton PVE12 - page 16

    16 Figure 1 1. Special Bearing Race Installation T ools. “ C ”“ B ” “ A ” .375 Nominal Pipe Size ABC 1 1/2 ” 4 ” 1.625 1.900 2 ” 4 ” 2.125 2.375 Schedule 80 (extra heavy) .005 Figure 12. Shaft Seal Driver . Aluminum ring Heavy wall tubing Press ring on end of tubing. 0.125 2.500 1.439 1.440 0.250 6.50 1.500 .375 .005 F . Replace ...

  • Eaton PVE12 - page 17

    17 G. T roubleshooting T able 3 lists the common difficulties experienced with piston pumps and hydraulic systems. It also indicates probable causes and remedies for each of the troubles listed. TROUBLE PROBABLE CAUSE REMEDY Excessive pump noise. Low oil level in the reservoir Air in the system V acuum condition Oil too thick Cold weather Fill rese ...

  • Eaton PVE12 - page 18

    18 Section VI – Overhaul A. General CAUTION Before breaking a circuit connection, make certain that power is off and system pressure has been released. Lower all vertical cylinders, discharge accumulators, and block any load whose movement could generate pressure. After removing the pump from the system and before disassembly , cap or plug all po ...

  • Eaton PVE12 - page 19

    19 55 54 53 52 51 50 49 27 30 60 59 58 57 34 35 36 45 55 54 53 52 51 50 49 27 33 72 23 71 70 44 42 40 34 37 35 31 29 26 25 43 41 39 38 36 28 32 64 65 66 69 74 68 67 Figure 13. PVE19/21 Exploded View Refer to Service Drawings for assembly instructions and torque values. Item Description Qty 70 O-ring 1 71 Retaining Ring 1 25 Screw 5 67 Plug 1 68 O-r ...

  • Eaton PVE12 - page 20

    20 Figure & Index No. Units per Assembly Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 6 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Screw Gasket O-Ring Lockwire and Seal Adjusting Plug Back-Up Ring O-Ring Spri ...

  • Eaton PVE12 - page 21

    21 4 5 6 7 8 9 10 1 24 3 2 72 56 57 58 59 60 61 62 30 25 55 54 53 52 51 50 49 46 47 48 44 45 27 55 54 53 52 51 50 49 Figure 13. PVE19/21 Exploded View ...

  • Eaton PVE12 - page 22

    22 63 9 10 8 7 5 12 1 18 17 16 15 14 13 4 11 19 23 24 3 2 21 20 22 69 68 67 71 70 73 26 29 31 66 43 42 41 40 39 34 38 37 36 35 33 28 32 65 64 ...

  • Eaton PVE12 - page 23

    23 3. Inspect spring (8) and (16) for wear and parallelism. Spring ends must be parallel. Replace if spring is warped or wear is evident. 4. Inspect seat (9) for wear in the area of spool contact. 5. Inspect spool (10) for excessive wear , galling, scratches, etc. If scratches exist across the spool land, replace the spool and inspect the body bore ...

  • Eaton PVE12 - page 24

    24 Figure 14. Cylinder bloc k subassembly disassembly tool. (T ighten nut, remove snap ring, loosen nut to relieve spring tens ion). Figure 14a. Cylinder Block Subassembly parts. F . Inspection Repair and Replacement 1. Check bearing (32) for scoring or brinelling of the rollers (PVE 19/21). 2. Check bearing spacer (33) for burrs (PVE 19/21). 3. In ...

  • Eaton PVE12 - page 25

    25 NOTE If shims (51) were destroyed during disassembly , a yoke bearing preload adjustment must be made at assembly . c. Slide the yoke from side to side to loosen the yoke bearing races (54) within the housing. The races are a normal slip fit but may be tight. Use an open end wrench between the yoke and the pintle bearing to help slide out the ra ...

  • Eaton PVE12 - page 26

    26 Figure 16. Removal of Front Bearing Race. Figure 17. Front Bearing Removal. Shaft Seal 1 1/2 ” heavy wall tubing 6 ” long. See Figure 1 1. Arbor Press Here Retaining Ring Figure 18. Front Bearing Installation. Shoulder 1 1/2 ” heavy wall tubing 6 ” long. See Figure 1 1. Arbor Press Here G. Assembly of Housing Parts NOTE If a new shaft be ...

  • Eaton PVE12 - page 27

    27 a. Assemble pintle bearings (55) on each end of the yoke and insert bearing races (54). b. Install bearing spacer (53) at one pintle end. c. Install O-Ring (52) against spacer (53) into the groove, then install a 0.010 inch shim (51) under pintle cover (50). Install four pintle cover screws (49) and torque to 175 – 185 lbf. in. NOTE Early desi ...

  • Eaton PVE12 - page 28

    28 H. Disassembly of V alve Block 1. Do not disassemble check valve parts (64) through (66), unless action of the valve indicates a problem. Check the valve action with a pencil or a screwdriver . Press the check valve in against the spring, it should return and hold firm against the seat. If the check valve is defective, remove and replace the com ...

  • Eaton PVE12 - page 29

    29 2. Install pipe plug (69) into valve block (26) and secure. 3. Assemble a new O — Ring (68) on hex plug (67) and thread plug into place. K. Shaft Bearing Preload Adjustment (PVE 19/21 only) NOTE If the shaft bearings, shaft, valve block or housing were not replaced, use the bearing spacer removed during the disassembly procedure to preload the ...

  • Eaton PVE12 - page 30

    30 Section VII – T est Procedure A. T est Conditions FLUID MEDIUM: SAE 10W meeting API service classification MS or equivalent. FLUID TEMPERA TURE: 120 ° F ± 5 ° F at pump outlet. Fluid entering the pump must be maintained below a maximum contamination limit of class four according to NAS1638. B. Preliminary Check 1. Rotate the drive shaft thr ...

  • Eaton PVE12 - page 31

    31 F . Performance T est of PVE 12/19/21 Piston Pump with “ CG ” Compensator Control 1. Operate pump at 1200 RPM. Set remote control valve to minimum pressure setting. 2. Refer to Figure 23 and adjust load valve (1) and globe valve (1) to 100 PSI system pressure at P1. Observe maximum pump flow and maximum case leakage requirement noted in T ab ...

  • Eaton PVE12 - page 32

    32 G. Performance T est of PVE 12/19/21 Piston Pump with “ CV ” , “ CVP ” , “ CVPC ” and “ CVPD ” Compensator Control NOTE Refer to Figure 24 for location of circuit components. 1. Open load valve one (1) and turn compensator adjust - ment plug clockw ise until seated. 2. Operate at 1200 RPM and 100 Psig outlet pressure until all ai ...

  • Eaton PVE12 - page 33

    33 Model Compensator Pressure Setting Psig T able 9. Load sensing compensator adjustment range. Lockwire Standby Pressure P2 P @ USgpm (P2-P1) P @ Compensator Cracking Pressure (P2-P1) PVE19*-*-**-CV -10 PVE19*-*-**-CVP-12 PVE19*-*-**-CVPC-12 PVE12*-*-**-C**VPD41 PVE21*-*-**-CV -10 PVE21*-*-**-CVP-12 PVE21*-*-**-CVPC-12 Not Applicable Not Applicabl ...

メーカー Eaton カテゴリー Heat Pump

Eaton PVE12のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- PVE12の取扱説明書
- Eatonの製品カード
- パンフレット
- またはEaton PVE12の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Eaton PVE12の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Eaton PVE12の取り付け説明書、サービスマニュアル、簡易説明書、またはEaton PVE12のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Eaton PVE12の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Eaton PVE12デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがEaton PVE12を使用するのを助ける技術的文書のことです。説明書は通常、全てのEaton PVE12ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Eatonの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Eaton PVE12の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははEaton PVE12の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Eaton PVE12に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Eaton PVE12デバイスの基本機能を使うにあたってのヒント。 Eaton PVE12のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Eaton PVE12に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるEaton PVE12のメーカー/サービスへの連絡先に関する情報。

Eaton PVE12についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもEaton PVE12の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがEaton PVE12で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)