Universal Security Instruments MICN109の取扱説明書

17ページ 0.11 mb
ダウンロード

ページに移動 of 17

Summary
  • Universal Security Instruments MICN109 - page 1

    THANK YOU for purchasing this combination alarm. It is designed to detect smoke, carbon monoxide and natural gas (methane) which reaches the sensor . It is not designed to detect fire, heat, flames or any other gas. This manual includes important information regarding where to inst all the alarm, how to operate, maintenance, testing and product fea ...

  • Universal Security Instruments MICN109 - page 2

    ALARM LIMIT A TIONS AND FUNCTIONS  This Combination Ionization Smoke/Carbon Monoxide (CO)/Natural Gas alarm requires constant 120 V AC power to operate properly .  There are three basic smoke alarm types: IoPhic , Ionization and Photoelectric . IoPhic is an ionization alarm containing a patent-pending Universal Smoke Sensing T echnology . IoP ...

  • Universal Security Instruments MICN109 - page 3

    WHA T YOU SHOULD KNOW ABOUT CO Carbon monoxide (CO) is an insidious poison. It is a colorless, odorless, tasteless gas. It is a cumulative poison. Even low levels of CO have been shown to cause brain and other vital organ damage in unborn infants with no effect on the mother . The following symptoms are related to CARBON MONOXIDE POISONING and shou ...

  • Universal Security Instruments MICN109 - page 4

    • Locate the first combination alarm in the immediate area of the bedrooms. T ry to protect the escape route as the bedrooms are usually farthest from an exit. If more than one sleeping area exists, locate additional combination alarms in each sleeping area. If a hall is more than 40 feet (12 meters) long, install a combination alarm at each end. ...

  • Universal Security Instruments MICN109 - page 5

    In general, install combination Smoke, CO and Gas Alarms: • WHERE YOU CAN HEAR THE ALARM FROM ALL SLEEPING AREAS. • In or near bedrooms and living areas or wherever you suspect a smoke, gas or CO exposure is likely . • On each level of a multilevel home. IMPORT ANT! Installation in an improper location can af fect the sensitive electronic com ...

  • Universal Security Instruments MICN109 - page 6

    Page 6 RECOMMENDED PLACEMENT : NOTE: For any location, make sure no door or other obstruction could prevent the smoke, carbon monoxide or gas from reaching the alarm. WHERE THIS ALARM SHOULD NOT BE INST ALLED T o avoid causing damage to the unit, to provide optimum protection, and to prevent unnecessary alarms. Do NOT locate this alarm: • In gara ...

  • Universal Security Instruments MICN109 - page 7

    • Good ventilation is recommended when household cleaning supplies or similar contaminants are used. • Excessive spillage or reverse venting of fuel-burning appliances caused by outdoor ambient conditions, such as:  Wind direction and/or velocity , including high gust s of wind. Heavy air in the vent pipes (cold/ humid air with extended peri ...

  • Universal Security Instruments MICN109 - page 8

    DO NOT T AMPER WITH WIRES WHEN POWER IS ON! For alarms that are used as single non-interconnected, stand-alone alarms, do not connect the yellow wire to anything. Insulate this wire (tape it) in place to make certain the yellow wire cannot contact any metal parts. IInterconnected alarms can provide earlier warning of fire than stand-alone alarms, e ...

  • Universal Security Instruments MICN109 - page 9

    Page 9 The yellow wire is used only for multiple station operations with USI ELECTRIC or UNIVERSAL Model alarms only. Connecting this yellow wire to any other circuits may result in damage and alarm malfunction. When alarms are interconnected, all alarms must be powered from a single AC branch circuit. If local codes do not permit, be sure the neut ...

  • Universal Security Instruments MICN109 - page 10

    SMOKE ALARM LA TCHING LED INDICA TOR: The alarm had prevously detected smoke and had alarmed. The red LED is of f and blinks on every 5 seconds until reset. Follow the reset instructions to remove the latching LED. CO ALARM LA TCHING LED INDICA TOR: The alarm had previously detected CO and had alarmed. The red LED is off and blinks on every 5 secon ...

  • Universal Security Instruments MICN109 - page 11

    WH A T TO DO IF NA TURAL GAS IS DETECTED: 1. Leave the house immediately , opening doors and windows as you leave. 2. Do not use your telephone or appliances. Do not turn any light switches off or on. Any spark or flame could ignite the gas. 3. Call 91 1 and your gas company from a phone that is away from your home. 4. Do not reenter the area until ...

  • Universal Security Instruments MICN109 - page 12

    NEVER use an open flame of any kind to test this smoke alarm. Y ou might accidentally damage or set fire to the smoke alarm or to your home. The built-in test switch accurately tests the smoke alarm's operation as required by Underwriters Laboratories Inc. (UL). (UTHA) Sensitivity Indicating Means The sensitivity indicating means for this Smok ...

  • Universal Security Instruments MICN109 - page 13

    Page 13 CO AND NA TURAL GAS ALARM LIMIT A TIONS Alarms have limitations. Like any other electronic device, Smoke, CO and Natural Gas alarms are not foolproof. Smoke, CO and Natural Gas alarms have a limited operational life. Y our alarm must be tested weekly , because it could fail to operate at any time. If your aAlarm fails to test properly , or ...

  • Universal Security Instruments MICN109 - page 14

    DEVELOP AND PRACTICE A PLAN OF ESCAPE BASICS OF ESCAPE PLAN o Make a floor plan indicating all doors and windows and at least two escape routes from each room. Second story windows may need a rope or chain ladder . o Have a family meeting and discuss your escape plan, showing everyone what to do in case of fire. o Determine a place outside your hom ...

  • Universal Security Instruments MICN109 - page 15

    FCC P ART 15 RADIO FREQUENCY DEVICES This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequen ...

  • Universal Security Instruments MICN109 - page 16

    Page 16 On and Blinks off approx every 20 seconds AC Power is present. DC power is present Silent Off and Blinks on approx every 40 seconds Off Off Alarm is powered by battery backup. AC Power is not present. Check the breaker or fuse box for power. If the breaker or fuse box looks normal, call a licensed electrician for assistance. 1 beep, 1 secon ...

  • Universal Security Instruments MICN109 - page 17

    * 288-3482-00 © 2010 UNIVERSAL SECURITY INSTRUMENTS, INC Printed in China TEN YEAR LIMITED W ARRANTY MODELS MICN102, MICN102L MODELS MICN 109, MICN 109L USI ELECTRIC, INC./UNIVERSAL SECURITY INSTRUMENTS, INC. ("USI") warrants your USI product to be free from defects in material and workmanship for a period of ten (10) years from the date ...

メーカー Universal Security Instruments カテゴリー Carbon Monoxide Alarm

Universal Security Instruments MICN109のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- MICN109の取扱説明書
- Universal Security Instrumentsの製品カード
- パンフレット
- またはUniversal Security Instruments MICN109の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Universal Security Instruments MICN109の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Universal Security Instruments MICN109の取り付け説明書、サービスマニュアル、簡易説明書、またはUniversal Security Instruments MICN109のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Universal Security Instruments MICN109の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Universal Security Instruments MICN109デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがUniversal Security Instruments MICN109を使用するのを助ける技術的文書のことです。説明書は通常、全てのUniversal Security Instruments MICN109ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Universal Security Instrumentsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Universal Security Instruments MICN109の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははUniversal Security Instruments MICN109の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Universal Security Instruments MICN109に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Universal Security Instruments MICN109デバイスの基本機能を使うにあたってのヒント。 Universal Security Instruments MICN109のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Universal Security Instruments MICN109に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるUniversal Security Instruments MICN109のメーカー/サービスへの連絡先に関する情報。

Universal Security Instruments MICN109についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもUniversal Security Instruments MICN109の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがUniversal Security Instruments MICN109で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)