GE GEK-45404Fの取扱説明書

32ページ 1.65 mb
ダウンロード

ページに移動 of 32

Summary
  • GE GEK-45404F - page 1

    GEK-45404F   MULTILIN  GE Power Management INSTRUCTIONS OVERVOLTAGE RELAYS TYPES IAV, 51 D K 52 C D K GE Power Management 205 Great Valley Parkway Malvern, PA 19355, USA Click here to get to our homepage: http://www.gemultilin.com/ ...

  • GE GEK-45404F - page 2

    GEK-45404 2 DESCRIPTION ................................................................................................................................................... 3 APPLICATION ................................................................................................................................................... 4 RATINGS ...... ...

  • GE GEK-45404F - page 3

    GEK-45404 3 D ES CRIPTIO N Thes e are si ngle- phase, sens itiv e overvo lta g e relay s o f th e i nduc ti on disk construc ti on. The y a r e e quipped w it h a tim e dia l s o a s t o provid e adj ustabl e tim e dela y i n thei r opera ti on. Th e relay s are principa ll y a pp li cab le f o r sen s itiv e overvo lta g e gr ound det ec ti on fo ...

  • GE GEK-45404F - page 4

    GEK-45404 4 A PPLICA TION Thes e are single- phase, sens itive , time- dela y overvo ltag e relay s . The y a r e p rincipa ll y a pp li cabl e for sens itiv e overvo ltag e gr ound det ec ti on fo r high- impedan ce gr ounded g enerator s o r for ung rounded powe r s y st ems . Thes e relay s a ll hav e a capac ito r i n serie s w it h th e opera ...

  • GE GEK-45404F - page 5

    GEK-45404 5 br oke n de lt a vo ltag e w ill therefo r e be th ree time s th e norma l delt a phase-to-phas e vo ltag e w it h no fault. RA TINGS Th e opera ting-cir cuit rating s ava ilabl e are s hown in Tabl e I . Th e opera tin g co il will sta nd rated voltage continuously on any tap. RELAY VOLTAGE RATINGS 60HZ 50HZ IAV51D 115 115 199 199 345 ...

  • GE GEK-45404F - page 6

    GEK-45404 6 suc h tha t the tri ppin g cu rren t doe s no t pa ss thr oug h th e c ont act s o f th e targe t a nd s eal-i n co il o f the protective relay. BURDENS Burdens for the various relay types are give in Tables IIIA and B. TABLE IIIA 60 - Cycle Burdens Rated Voltage RELAY TYPES VOLTAGE RATING TAP**SETTING VOLT-AMPS POWER FACTOR WATTS 1AV51 ...

  • GE GEK-45404F - page 7

    GEK-45404 7 50 - Cycle Burdens at Rated Voltages RELAY TYPES VOLTAGE RATING TAP**SETTING VOLT-AMPS POWER FACTOR WATTS IAV51D 345 A(28) 31.9 0.36 11.4 B(42) 28.3 0.56 15.8 C(70) 21.0 0.79 16.6 D(112) 12.8 0.93 11.9 IAV51K 67 A(5.4) 28.8 0.29 8.4 IAV52K B(7.5) 26.6 0.45 12.1 C(12.5) 21.1 0.71 14.9 D(20) 16.0 0.86 13.7 115 No Taps 25.0 0.41 10.1 IAV52 ...

  • GE GEK-45404F - page 8

    GEK-45404 8 50 - Cycle Burden at Rated Voltages RELAY TYPES VOLTAGE RATINGS TAP**SETTINGS VOLT-AMPS POWER FACTOR WATTS 1AV51D 115 A(10) 0.52 0.98 0.52 B(15) 0.67 0.99 0.67 C(25) 1.0 1.0 1.0 D(40) 1.52 1.0 1.52 IAV51D 199 A(16) 0.32 0.85 0.27 B(24) 0.5 0.93 0.46 C(40) 0.83 0.97 0.81 D(64) 1.33 0.99 1.32 IAV51D 345 A(28) 0.39 0.96 0.37 B(42) 0.58 0.9 ...

  • GE GEK-45404F - page 9

    GEK-45404 9 Th e I AV 52 K rela y i s s imila r t o t h e I AV 51 K ex cep t that it ha s tw o, inst ea d o f one, norma lly - open contacts. Th e I AV 52 C i s a low-pi c kup, time- overvo ltag e rela y w it h tw o norma lly- open cont acts . I t ha s a seal- i n element . I t ha s a capac ito r c onn ecte d i n serie s w it h th e opera tin g c o ...

  • GE GEK-45404F - page 10

    GEK-45404 10 RECEIVING , HA NDLI NG , A ND STORA GE RECEIVING Thes e relays , whe n no t shi pped a s a par t o f a c ontro l pane l , w ill b e shi pped in cart on s desig ne d to prot ec t them ag ainst damage . I mmediate l y upon r eceip t o f th e rel ay , an exa minati on shoul d b e made fo r an y d a m a g e sus tain e d durin g s hi pme nt ...

  • GE GEK-45404F - page 11

    GEK-45404 11 CAUTION : Ev er y ci rcui t i n th e dra wou t cas e h a s a n aux iliar y brush . I t i s esp ecia ll y importan t o n cu rrent circuit s a nd oth er circuit s wit h shortin g bar s tha t th e aux iliar y brus h be ben t hig h enough to en gag e th e co nn ectin g p lu g o r t es t pl u g bef o re the mai n brushes d o. Thi s w ill p ...

  • GE GEK-45404F - page 12

    GEK-45404 12 ELECTRICAL TESTS Drawout Relays - General Sin ce a ll draw ou t relay s i n servi ce oper at e i n thei r cas es , it i s r eco mme nded tha t the y b e teste d in thei r cas e s o r a n equivalen t st ee l case . In thi s wa y a n y m a gn e ti c e ff ect s o f th e enclosur e w ill be accuratel y dup li cate d durin g tes ting . A re ...

  • GE GEK-45404F - page 13

    GEK-45404 13 INST A LLA TI ON INSPECTION A t th e tim e o f i nsta llati on, th e rela y s houl d b e ins p ect e d fo r t arni sh e d cont acts , loos e screws , o r o th er impe rf ec ti ons . I f an y t r oubl e i s f ound, it s houl d b e co rr ect ed ; s ee MAIN TE NANCE . Ch ec k the nameplate for model number and rating. LOCATION Th e loca t ...

  • GE GEK-45404F - page 14

    GEK-45404 14 ADJUSTMENTS Target and Seal-in Unit Fo r tri p co il s opera tin g on cu rren t rangin g fro m 0.2 up to 2.0 ampere s a t th e minimum c ontrol voltage, set the target and seal-in tap plug in the 0.2- ampere tap. Fo r tri p co il s opera tin g on cu rrent s rangin g fro m 2 t o 30 ampere s a t th e minimum c ontro l vo ltag e, place th ...

  • GE GEK-45404F - page 15

    GEK-45404 15 Time Setting Th e tim e o f opera ti on o f th e overvo ltag e rela y i s deter mine d pr imaril y b y t h e se ttin g o f th e tim e di al. Furthe r adj us tmen t i s obtaine d b y m ovin g th e p ermanen t magnet a l on g it s s uppor tin g s hel f ; m oving the magnet in toward the back of the relay decreases the time, while moving ...

  • GE GEK-45404F - page 16

    GEK-45404 16 CONTACT CLEANING Fo r cl eani n g fin e s ilve r c ont act s , a flexi ble burnishin g t oo l s houl d b e u se d. Thi s c onsist s o f a flexi bl e stri p o f meta l wit h an etched roug hened su rf ace , resemb lin g i n e ff ec t a s upe rfin e f ile . The po lishin g ac ti on i s s o de li cate tha t no scratche s ar e left , y e t ...

  • GE GEK-45404F - page 17

    GEK-45404 17 LIS T O F FI G UR ES FIG. 1 (8043181) TYPE IAV51D RELAY, REMOVED FROM CASE, FRONT VIEW FIG. 2 (8043182) TYPE IAV51D RELAY, REMOVED FROM CASE, REAR VIEW FI G . 3 (K6400439-5) I N TER NA L C ONNECTION S O F TH E TYPE I AV 51 D REL AY, FRONT VIEW FI G . 4 (0362A514-3) I N TER NA L C ONNECTION S O F TH E TYPE I AV 51 K REL AY, FRONT VIEW F ...

  • GE GEK-45404F - page 18

    GEK-45404 18 FIG. 1 (8043181-0) TYPE IAV51D RELAY, REMOVED FROM CASE, FRONT VIEW ...

  • GE GEK-45404F - page 19

    GEK-45404 19 FIG. 2 (8043182-0) TYPE IAV51D RELAY, REMOVED FROM CASE, R EAR VIEW ...

  • GE GEK-45404F - page 20

    GEK-45404 20 FIG. 3 (K-6400439-5) INTERNAL CONNECTIONS OF THE TYPE IAV51D RELAY, FRONT VIEW ...

  • GE GEK-45404F - page 21

    GEK-45404 21 FIG. 4 (362A514-3) INTERNAL CONNECTIONS OF THE TYPE IAV51K RELAY, FRONT VIEW ...

  • GE GEK-45404F - page 22

    GEK-45404 22 FIG. 5 (K-6556505-0) INTERNAL CONNECTIONS OF THE TYPE IAV52C RELAY, FRONT VIEW ...

  • GE GEK-45404F - page 23

    GEK-45404 23 FIG. 6 (418A790-0) INTERNAL CONNECTIONS OF THE TYPE IAV52D RELAY, FRONT VIEW ...

  • GE GEK-45404F - page 24

    GEK-45404 24 FIG. 7 (0257A8379-0) INTERNAL CONNECTIONS OF THE TYPEIAV52K RELAY, FRONT VIEW ...

  • GE GEK-45404F - page 25

    GEK-45404 25 FIG. 8 (0275A2004-0) EXTERNAL CONNECTION DIAGRAM OF TYPES IAV51KAND IAV52K FOR GENERATOR GROUND-FAULT PROTECTION ...

  • GE GEK-45404F - page 26

    GEK-45404 26 FIG. 9 (0275A2003-0) EXTERNAL CONNECTION DIAGRAM OF TYPE IAV51D, IAV52C AND IAV52D FOR GROUND-FAULT DETECTION ON AN UNGROUNDED SYSTEM ...

  • GE GEK-45404F - page 27

    GEK-45404 27 FIG. 10 (K6154391-3) TEST CONNECTIONS FOR OVERVOLTAGE RELAYS ...

  • GE GEK-45404F - page 28

    GEK-45404 28 NOTE: TD=Time Dial setting FIG. 11 (0178A8140-0) TIME VOLTAGE CURVES FOR TYPES IAV51D, 51K, 52D, AND 52K RELAYS ...

  • GE GEK-45404F - page 29

    GEK-45404 29 FIG. 12 (8025039-0) CROSS SECTION OF DRAWOUT CASE SHOWING POSITION OF AUXILIARY BRUSH ...

  • GE GEK-45404F - page 30

    GEK-45404 30 FIG. 13 (0275A4399-0) OUTLINE OF IAV51K AND IAV52K EXTERNAL CAPACITOR ...

  • GE GEK-45404F - page 31

    GEK-45404 31 FIG. 14 (K6209270-2) OUTLINE AND PANEL DRILLING FOR RELAY TYPES IAV51D, 52D AND IAV52C ...

  • GE GEK-45404F - page 32

    GEK-45404 32 * FIG. 15 (K6209271-8) OUTLINE AND PANEL DRILLLING FOR RELAY TYPES IAV51K AND IAV52K ...

メーカー GE カテゴリー Portable Generator

GE GEK-45404Fのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- K-45404Fの取扱説明書
- GEの製品カード
- パンフレット
- またはGE GEK-45404Fの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、GE GEK-45404Fの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、GE GEK-45404Fの取り付け説明書、サービスマニュアル、簡易説明書、またはGE GEK-45404Fのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、GE GEK-45404Fの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

GE GEK-45404Fデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGE GEK-45404Fを使用するのを助ける技術的文書のことです。説明書は通常、全てのGE GEK-45404Fユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

GEの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. GE GEK-45404Fの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGE GEK-45404Fの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。GE GEK-45404Fに関してこのドキュメントで見つけることができる全てのヒントの目次
3. GE GEK-45404Fデバイスの基本機能を使うにあたってのヒント。 GE GEK-45404Fのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。GE GEK-45404Fに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGE GEK-45404Fのメーカー/サービスへの連絡先に関する情報。

GE GEK-45404Fについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGE GEK-45404Fの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGE GEK-45404Fで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)