United States Stove 6110の取扱説明書

24ページ 1.48 mb
ダウンロード

ページに移動 of 24

Summary
  • United States Stove 6110 - page 1

    USSC 1 Please read this entire manual before installation and use of this appliance. Failure to follow these instructions could result in property damage, bodily injury, or even death. Contact your local building or fire officials about restrictions and installation inspection requirements in your area. Save these instructions. Ì Ì Ì Owner’s M ...

  • United States Stove 6110 - page 2

    2 USSC T ABLE OF CONTENTS .............................................................................................. 2 SAFETY PRECAUTIONS ........................................................................................... 3 SPECIFICA TIONS .................................................................................................. ...

  • United States Stove 6110 - page 3

    USSC 3 Safety Precautions IMPORT ANT : Read this entire manual before installing and operating this product. Failure to do so may result in property damage, bodily injury , or even death. Proper installation of this furnace is crucial for safe and efficient operation. Install vent at clearances specified by the vent manufacturer . Do not connect th ...

  • United States Stove 6110 - page 4

    4 USSC Specifications Heat Output 1 50,000 to 75,000 BTU/hr . Heating Capacity 2 800 - 2,000 sq. ft. Fuel Burn Rate 3 2.0 - 6.0 lbs./hr . Burn T ime (lowest setting) 125 hours continuous Hopper Capacity 250 lbs Heating S pecifications Height 47 in. Width 25-1/2 in. Depth 35-1/2 in. Weight 350 lbs. Dimensions 1 BTU output will vary depending on the ...

  • United States Stove 6110 - page 5

    USSC 5 Fuel Considerations SHELLED CORN (Dry , preferably corn with 1 1% or less moisture content) • • • • • • • Optimum moisture content of corn should be 1 1% or less. Wet corn will rapidly deteriorate furnace components, reduce efficiency and void all warranties. Purchase a moisture tester if in doubt. Corn must be clean and free f ...

  • United States Stove 6110 - page 6

    6 USSC INST ALLA TION OPTIONS Read this entire manual before you inst all and use your Multi-Fuel Furnace. Failure to follow instructions may result in property damage, bodily injury , or even death! (See specific inst allation det ails for clearances and other inst allation requirements) As a Primary Furnace —the unit functions independently of ...

  • United States Stove 6110 - page 7

    USSC 7 Installation CLEARANCES NOTE: Distance on the left-hand side of y our Multi-Fuel Furnace is set at 24 inches for suitable access to the control panel and for fuel loading. This distance may be less, but not less than 7 inches. ...

  • United States Stove 6110 - page 8

    8 USSC Installation VENTING REQUIREMENTS Inst all vent at clearances specified by the vent manufacturer . Do not connect the pellet vent to a vent serving any other appliance or furnace. Do not inst all a flue damper in the exhaust venting system of this unit. The following installation guidelines must be followed to ensure conformity with both the ...

  • United States Stove 6110 - page 9

    USSC 9 Installation VENT TERMINA TION CLEARANCES: A ----- Minimum 4-foot clearance below or beside any door or window that opens. B ----- Minimum 1-foot clearance above any door or window that opens. C ----- Minimum 3-foot clearance from any adjacent building. D ----- Minimum 7-foot clearance from any grade when adjacent to public walkways. E ----- ...

  • United States Stove 6110 - page 10

    10 USSC Installation THROUGH THE W ALL INST ALLA TION (RECOMMENDED INST ALLA TION) T o vent the unit through the wall, connect the pipe adapter to the exhaust motor adapter . If the exhaust adapter is at least 18-inches above ground level, a straight section of pellet vent pipe can be used through the wall. Y our furnace dealer should be able to pr ...

  • United States Stove 6110 - page 11

    USSC 11 Installation PRIMAR Y FURNACE SECONDAR Y (ADD-ON) FURNACE When installed as a seondary furnace, a Duct Damper must be installed between the air discharge of the Pellet furnace and the primary (Gas, Electric, etc.). Damper must be a mechanical (spring return) style damper with a simple closure switch to determine if damper is opened or close ...

  • United States Stove 6110 - page 12

    12 USSC Do not operate your furnace with the viewing door open. The auger will not feed fuel under these circumst ances and a safety concern may arise from sp arks or fumes entering the room. A working smoke detector must be inst alled in the same room as this product. Hopper Lid must be closed during operation. The auger will not feed fuel if the ...

  • United States Stove 6110 - page 13

    USSC 13 Heat Range Room Fan Draft Fan Aux. Auto Manual CONTROL PANEL T urning the furnace OFF/ON, as well as adjustments for the fuel feed rate and room fan speed are performed by pressing the appropriate button(s) on the control panel which is located on the lower lef t-hand side of your American Harvest furnace. This unit can be changed between a ...

  • United States Stove 6110 - page 14

    14 USSC SHUT DOWN PROCEDURE Press the “OFF” button on the control p anel to put the furnace in shut down mode. At this time, the red light above the “OFF” button will illuminate. Once this is done, the auger will stop feeding fuel, but the room air fan(s) and draft fan will continue to operate. When the internal temperature of the unit drop ...

  • United States Stove 6110 - page 15

    USSC 15 Maintenance Operation DAIL Y OPERA TION The hopper and furnace top will be hot during operation; therefore, you should always use some type of hand protection when refueling your furnace. Never place your hand near the auger while the furnace is in operation. In the event of a power out age , the furnace WILL NOT function. It is very import ...

  • United States Stove 6110 - page 16

    16 USSC INTERIOR CHAMBERS Remove the two(2) cleanout plates on each side of the damper control. Using the cleaning tools provided, clean all ash and fue l matter from the burn chamber . This may need to be done daily depending on fuel consumption. Periodically remove and clean the burnpot and the area inside the burnpot housing. In particular it is ...

  • United States Stove 6110 - page 17

    USSC 17 6100 Parts Diagram ...

  • United States Stove 6110 - page 18

    18 USSC 6100 Parts List 1 5 9 8 10 12 7 4 6 11 3 2 Item Part No. Title Qt y . 1 25507 Feed Door 1 2 25492 Handle, Door 1 3 83506 3/8 x 1 1/4 Roll Pin 1 4 891053 Door Glass w/o Logo 1 5 88066 5/8” Rope Gasket 4.5 ft 6 88087 Glass Gasket (1 x 1 3/16) 3 ft 7 25520 Bottom Glass Ret ainer 1 8 25521 T op Glass Retainer 1 6100/61 10 P ARTS LIST Item Par ...

  • United States Stove 6110 - page 19

    USSC 19 6110 Parts Diagram ...

  • United States Stove 6110 - page 20

    20 USSC 6110 Parts List ...

  • United States Stove 6110 - page 21

    USSC 21 Wiring Diagram ...

  • United States Stove 6110 - page 22

    22 USSC T rouble Shooting PROBLEM CAUSE: Not enough combustion air; Fuel has too much moisture. Viewing window becoming black shortly af ter start-up. • Adjust the air damper to a more open position. • Use a fuel with less moisture content PROBLEM CAUSE: Not enough combustion air; Fuel has too much moisture. “Black Popcorn” is present in th ...

  • United States Stove 6110 - page 23

    USSC 23 Err or Codes Below is a chart describing the Error Codes that might be displayed if an error occurs with your furnace. Error Code Err1 Err2 Err3 Err4 Err5 Err6 Err7 Err8 Error Descrption The high limit temperature sensor has tripped. Furnace ran out of fuel during normal operation. The furnace was unable to reach the Room Fan On temperature ...

  • United States Stove 6110 - page 24

    24 USSC THIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM YOUR KING OR ASHLEY, AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE. WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER. WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWIN ...

メーカー United States Stove カテゴリー Furnace

United States Stove 6110のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 6110の取扱説明書
- United States Stoveの製品カード
- パンフレット
- またはUnited States Stove 6110の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、United States Stove 6110の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、United States Stove 6110の取り付け説明書、サービスマニュアル、簡易説明書、またはUnited States Stove 6110のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、United States Stove 6110の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

United States Stove 6110デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがUnited States Stove 6110を使用するのを助ける技術的文書のことです。説明書は通常、全てのUnited States Stove 6110ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

United States Stoveの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. United States Stove 6110の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははUnited States Stove 6110の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。United States Stove 6110に関してこのドキュメントで見つけることができる全てのヒントの目次
3. United States Stove 6110デバイスの基本機能を使うにあたってのヒント。 United States Stove 6110のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。United States Stove 6110に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるUnited States Stove 6110のメーカー/サービスへの連絡先に関する情報。

United States Stove 6110についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもUnited States Stove 6110の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがUnited States Stove 6110で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)