Omega Engineering Four Zone Temperature OMA-VM520の取扱説明書

12ページ 0.51 mb
ダウンロード

ページに移動 of 12

Summary
  • Omega Engineering Four Zone Temperature OMA-VM520 - page 1

    M4548-0607 omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info U ser ’ s Guide MADE IN Shop online at Manual and Installati on Instructions Four Zone T emperature Monitor and Alarm Models: OMA-VM520 OMA-VM520-DCP ...

  • Omega Engineering Four Zone Temperature OMA-VM520 - page 2

    2 23 WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s custom ...

  • Omega Engineering Four Zone Temperature OMA-VM520 - page 3

    http://{Device IP Address}/ltx_conf.html Click on the “Server Properties” button. Enter the Subnet Mask and/or Gateway Address and click “Update Set- tings” Be sure to enter the correct Subnet Mask and Gate way Address for the net- work the OMA-V520-DCP is on. If the status web page does not di splay /load correctly (DCP units) Verify that ...

  • Omega Engineering Four Zone Temperature OMA-VM520 - page 4

    4 General purpose, dry contact input Wiring Diagram Alarm Relay Output Plug in Thermocouple Terminals 1234 K + K + K + K + Sensor 1 Sensor 2 Sensor 3 Sensor 4 K + K + K + K + K type thermocouples with integrated spade connectors 8 W atch the display and no te any messages present. If the Four Zone Temperature Monitor a nd Alarm does not an swer the ...

  • Omega Engineering Four Zone Temperature OMA-VM520 - page 5

    Temperature Monitor and Alarm will repeat the wa rning message. This warning message can be repeated up to 2 times by changing the pro- gramm ed value. See th e Programming Repeat Warning Messages se c- tion. If the correct PIN number is not ente red the Four Zone Temperature Moni- tor and Alarm will call the next pr ogramm ed contact te lephone nu ...

  • Omega Engineering Four Zone Temperature OMA-VM520 - page 6

    Accessing the Four Zone Temperat ure Monitor over the phone 1 From another phone line call the Four Zo ne Temperature Monitor and Alarm. The device will pick up after the progra m med number of rings (Default is 1). 2 To access all functions, enter the 4-digit "Full Access" PIN. (Factory default is 0000). To access only the "Acknow l ...

  • Omega Engineering Four Zone Temperature OMA-VM520 - page 7

    18 Sensor Reading Af ter Callouts If the Four Zone Temperature Monitor has called all programmed telephone numbers and not made contac t it will wait 20 minutes before attempting to callout again. Peri odically, the time before callouts resume will be displayed. 1: 510 > 2: 200 3: 4: CALL- OUTS IN 17:25 7 Programming Sensor Parameters 1. Accessi ...

  • Omega Engineering Four Zone Temperature OMA-VM520 - page 8

    ming this sensor and return to step 1.b j) You will hear “ Enter numb er then press pound” k) Enter the value then press # . ► Use * to program a negative number (i.e. *20 = -20º ) ► Acceptable range is -999 to 999 l) You will hear the value y ou just entered (i.e. 50º ) m) Proceed to step 4.a 4. Programming the callout delay time a) You ...

  • Omega Engineering Four Zone Temperature OMA-VM520 - page 9

    16 1: ok 2: ok 3: n/c 4: n/c Sensor Present Sensor Present Sensor Not Detected Sensor Not Detected Start Up W hen starting up, the Four Zone Temperature Monitor checks each temperature sensor input to verify that a sensor is connected. If a sensor is connected and has a reading within range, “ok” will be printed next to that sensors label. If a ...

  • Omega Engineering Four Zone Temperature OMA-VM520 - page 10

    10 Accessing the Program Me nu From the Main Menu, press 3 ► The "Full Access" PIN will be reques ted if the "Ack nowledge Only" PIN w as entered initially. If the corr ect "Full Access" PIN is not entered, the Four Zone Temperature Monitor and Alarm will hang up. Programming Contact Telephon e/Pager Numbers The Four ...

  • Omega Engineering Four Zone Temperature OMA-VM520 - page 11

    Changing the Callout Delay Time W hen a r efrigerat or or fre ezer’s temp erature is ou t of rang e the Four Zo ne Temperature Monitor and Al arm will wait this progra mmable amount of time before making telephone alert calls. (Default 2 minutes) 1 From t he Program Menu, press * 2 You will hear "Callout Ti me Delay is 2 minutes" 3 You ...

  • Omega Engineering Four Zone Temperature OMA-VM520 - page 12

    12 other device. See the Frequently Ask ed Questions section for details. 1 From t he Program Menu, press 4 to set the number of rings 2 You will hear the programmed number of rings 3 You will hear “Press one to change.” 4 Press 1 to make a change or 2 to return to the Program Menu 5 You will hear “ Enter number then press po und” 6 Enter t ...

メーカー Omega Engineering カテゴリー Smoke Alarm

Omega Engineering Four Zone Temperature OMA-VM520のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Four Zone Temperature OMA-VM520の取扱説明書
- Omega Engineeringの製品カード
- パンフレット
- またはOmega Engineering Four Zone Temperature OMA-VM520の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega Engineering Four Zone Temperature OMA-VM520の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega Engineering Four Zone Temperature OMA-VM520の取り付け説明書、サービスマニュアル、簡易説明書、またはOmega Engineering Four Zone Temperature OMA-VM520のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega Engineering Four Zone Temperature OMA-VM520の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Omega Engineering Four Zone Temperature OMA-VM520デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega Engineering Four Zone Temperature OMA-VM520を使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega Engineering Four Zone Temperature OMA-VM520ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omega Engineeringの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega Engineering Four Zone Temperature OMA-VM520の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega Engineering Four Zone Temperature OMA-VM520の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega Engineering Four Zone Temperature OMA-VM520に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega Engineering Four Zone Temperature OMA-VM520デバイスの基本機能を使うにあたってのヒント。 Omega Engineering Four Zone Temperature OMA-VM520のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega Engineering Four Zone Temperature OMA-VM520に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega Engineering Four Zone Temperature OMA-VM520のメーカー/サービスへの連絡先に関する情報。

Omega Engineering Four Zone Temperature OMA-VM520についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega Engineering Four Zone Temperature OMA-VM520の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega Engineering Four Zone Temperature OMA-VM520で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)