Crestron electronic CEN-TIAの取扱説明書

32ページ 0.58 mb
ダウンロード

ページに移動 of 32

Summary
  • Crestron electronic CEN-TIA - page 1

    Crestron CEN-TIA Telephone Interface Module Operations Guide ...

  • Crestron electronic CEN-TIA - page 2

    This document was prepared and written by th e Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product nam es and trademarks are the property of their respective owners. ©2007 Crestron Electronics, Inc. ...

  • Crestron electronic CEN-TIA - page 3

    Crestron CEN-TIA Telephone Interface Module Contents Telephone Interface Module: CEN-TIA 1 Introduction ............................................................................................................................... 1 Features and F unctions ............................................................................................ ...

  • Crestron electronic CEN-TIA - page 4

    ...

  • Crestron electronic CEN-TIA - page 5

    Crestron CEN-TIA Telephone Interface Module Telephone Interface Module: CEN-TIA Introduction Features and Functions • Remote control access from any phone • Custom do or chim e, ringer and alarm sounds • Personalized voice p rompts • Caller ID (CID) • Telephone paging fo r multiroom audio systems • Push-To-Talk half-duplex speakerphone ...

  • Crestron electronic CEN-TIA - page 6

    Telephone Interface Module Crestron CEN-TIA Caller ID See who is call ing befo re you answer by display ing Caller ID (C ID) infor mation on every touchpanel. Manage missed calls easily with complete caller information and management options di splayed on t he touchpanel screen. Telephone Paging The CEN-TIA adds telephone p aging capability to any ...

  • Crestron electronic CEN-TIA - page 7

    Crestron CEN-TIA Telephone Interface Module Specifications Specifications for the CEN-TIA are listed in the following table. CEN-TIA Specifications SPECIFICATION DETAILS Audio: Frequency Respons e ( AUDIO OUT ) 20Hz to 20kHz ± 0.5dB from MP3 file or AUDIO IN sources; 300Hz to 3kHz –3dB from PHONE LINE source; 300Hz to 3kHz –3dB from WAV file m ...

  • Crestron electronic CEN-TIA - page 8

    Telephone Interface Module Crestron CEN-TIA CEN-TIA Physical View CEN-TIA Overall Dimensions 7.07 in (17.96 cm) 1 2 3 4 5 6 7 6.36 in (16.15 cm) 1.80 in (4.57 c m) 8 9 10 11 12 13 14 15 4 • Telephone Interface Module: CEN- TIA Operations Guide – DOC. 6414 ...

  • Crestron electronic CEN-TIA - page 9

    Crestron CEN-TIA Telephone Interface Module Connectors, Controls, & Indicators # CONNECTORS*, CONTROLS, & INDICATORS DESCRIPTION 1 PWR LED Green LED indicates 24 Volts DC power supplied from Cresnet control network. 2 NET LED Yellow LED indicates communication w ith Cresnet Sy stem. 3 ACT LED Red LED indicates internal processi ng activity. ...

  • Crestron electronic CEN-TIA - page 10

    Telephone Interface Module Crestron CEN-TIA Connectors, Controls, & Indicators (Continued) # CONNECTORS*, CONTROLS, & INDICATORS DESCRIPTION 14 NET Four-position terminal bl ock connector for data and power. Connects to Cresnet control network. Pin 1 (24) Power Pin 2 (Y) Data Pin 3 (Z) Data Pin 4 (G) Ground 15 GROUND (1) 6-32 scre w, chassi ...

  • Crestron electronic CEN-TIA - page 11

    Crestron CEN-TIA Telephone Interface Module The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operatio n of t he equipm ent. If this hap pens the telephone company will provid e advance not ice in order for you to make necessary modifications to maintain uninterrupted service. If tro ...

  • Crestron electronic CEN-TIA - page 12

    Telephone Interface Module Crestron CEN-TIA Setup Network Wiring When wiring the network, consider th e following: • Use Crestron Certified Wire. • Use Crestron power supplies for Crestron equ ipment. • Provide sufficient power to the system. CAUTION: Insufficie nt power can lead to unpre dic t abl e resul t s or dam age to the equipment. Ple ...

  • Crestron electronic CEN-TIA - page 13

    Crestron CEN-TIA Telephone Interface Module Hardware Hookup Ventilation The CEN-TIA should be used in a well- venti l ated area. If the CEN-TIA is hot to the touch, consid er using forced air ventilatio n and/or incrementing th e sp acing between units. To prevent overheating, do not ope rate this product in an ar ea that exceeds the environmental ...

  • Crestron electronic CEN-TIA - page 14

    Telephone Interface Module Crestron CEN-TIA Hardware Connections for the CEN-TIA (Rear) PHONE LINE LAN: 10 BaseT/100 BaseTX HIGH SPEED ETHERNET TO LAN MEMORY: MMC CARD SLOT AUDIO INPUT: BALANCED AND UNBALANC ED AUDIO SIGNALS FROM LOCAL AUDIO SOU RCES AUDIO OUTPUT: BALANCED AND UNBALAN CED AUDIO SIGNALS TO AMP, ETC. NET: TO CONTRO L SYSTEM AND OTHER ...

  • Crestron electronic CEN-TIA - page 15

    Crestron CEN-TIA Telephone Interface Module Programming Software Have a questi on or commen t about Crestr on softwar e? Answers to f requently asked quest ions (FAQs) can be viewed in the Onl ine Help section of the Crestro n we bsi te. To post a question or vie w quest i ons you have submitted to Crestron’s True Blue Suppo rt, log in at http:// ...

  • Crestron electronic CEN-TIA - page 16

    Telephone Interface Module Crestron CEN-TIA Programming with Crestron Toolbox Text Console There are a num ber of commands that can only be e xecuted at the command line interface provided b y the Crestr on Toolbox Text Console. Text Console Commands COMMAND COMMAND SYNTAX DESCRIPTION ADDRBOOK ADD ADDRBOOK ADD <First Name> <Last Name> & ...

  • Crestron electronic CEN-TIA - page 17

    Crestron CEN-TIA Telephone Interface Module Text Console Commands (Continued) COMMAND COMMAND SYNTAX DESCRIPTION PHONE PHONE <ANSWER|HANGUP|STATUS> Performs telephone operations. PHONE DIAL <DIGITS> Digits may be: 1234567890 *# PHONE DTMF <DIGIT> [MS EC] Digits may be: 12345678 90*# MSEC: 0 to 65535 PHONE COUNTRY <COUNTRY> & ...

  • Crestron electronic CEN-TIA - page 18

    Telephone Interface Module Crestron CEN-TIA Text Console Commands (Continued) COMMAND COMMAND SYNTAX DESCRIPTION RSTOP RSTOP [<RECORDERID>] Stops recording an audi o file. SCRIPT SCRIPT <FILENAME> Runs the specified script. STOP STOP [<PLAYERID>] STOP <PLAYERNAME> Stop playing an aud io file. Audio Players: (0) MP3 (1) WAV X ...

  • Crestron electronic CEN-TIA - page 19

    Crestron CEN-TIA Telephone Interface Module • To incorporate the CEN-TIA into the system as an Ethernet de vice, drag the CEN-TIA (E thernet) from the Ethernet Control M odules | Ether net Audio Modules folder of the Device Library and dro p it in the System Views. Locating the Et hernet CEN-TIA in th e Device Libr ary • To incorporate the CEN- ...

  • Crestron electronic CEN-TIA - page 20

    Telephone Interface Module Crestron CEN-TIA • The initial Cresnet CEN-TIA will ta ke ID 49. Additional Cresne t CEN-TIA devices would be assigned t he lowest legal unused Cresnet I D (e.g., 03 if unused). The initial Ethern et CEN-TIA will take IP ID 03. If an additional Ethernet CEN-TIA is added th e IP ID of that unit would be 04. NOTE: In the ...

  • Crestron electronic CEN-TIA - page 21

    Crestron CEN-TIA Telephone Interface Module Programming Manager Programmi ng Manager is t he view whe re programm ers "program " a Crestron control system by assigning sig nals to sym bols. The sy mbol can be viewed by double clicking o n the i con or dra gging it into Detail View . A desc ription of the CE N-TIA symbol and for each signa ...

  • Crestron electronic CEN-TIA - page 22

    Telephone Interface Module Crestron CEN-TIA Uploading and Upgrading Crestron recommends using the latest pr ogramming software and that each device contains the latest firmware to take advantage of the most recently released feature s. However, before attem pting to upl oad or upgrade, it is necessary to establish communicat i on. O nce com m unica ...

  • Crestron electronic CEN-TIA - page 23

    Crestron CEN-TIA Telephone Interface Module • Click the Install the software au tomatically (Recommended) radi o but ton and then click Next . • When the wizard completes, click the Finish button. Indirect Serial Comm unication Indirect Serial Communication PC RUNNING CRESTRON TOOLBOX CONTROL SYSTEM CEN-TIA SERIAL , ETHERNET OR USB CRESNET • ...

  • Crestron electronic CEN-TIA - page 24

    Telephone Interface Module Crestron CEN-TIA TCP/IP Communication Ethernet Communic ation PC RUNNING CRESTRON TOO LBOX CE N-TIA ETHERNET • Establish di rect USB c ommunication between CE N-TIA a nd PC. • DHCP is e nabled by de fault on t he CEN-T IA. If yo u have to di sable it and manually est ablish an IP ad dress, do so u sing Crestro n Toolb ...

  • Crestron electronic CEN-TIA - page 25

    Crestron CEN-TIA Telephone Interface Module Program Checks Actions that ca n be perfo rmed on the CEN-TIA vary depe nding on whether it i s connected via Cresnet or Ethernet. Cresnet C onnec tions For Cresnet connections, usi n g Cre st ro n To o l bo x, di s pl ay the net w or k de vice tree ( Tools | Network De vice Tree ) to show all network de ...

  • Crestron electronic CEN-TIA - page 26

    Telephone Interface Module Crestron CEN-TIA Operation The CEN-TIA uses audio m essages as voice prompts and re sponses. These files can be WAV or MP3 files. Pre-recor de d me ssage files can be downloaded from Crestron’s website ( ftp ://ftp.crestron.com ). A Cresnet syst em with t he CEN-TIA m ay be program med to resp ond to i ncoming telephone ...

  • Crestron electronic CEN-TIA - page 27

    Crestron CEN-TIA Telephone Interface Module Problem Solving Troubleshooting The following table provides corrective action for possible trouble situatio n s. If further assistance is required, please contact a Crestron custom er service representative. CEN-TIA Troubleshooting TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTIO N Device does not function. De ...

  • Crestron electronic CEN-TIA - page 28

    Telephone Interface Module Crestron CEN-TIA Check Network Wiring Use the Right Wire In order to ensure optimum performance over the full ran ge of you r installation topology, Crestron Certified W ire, and only Crestron Certified Wire, may be used. Failure to do so may incur additional ch arges if support is required to identify performance d efici ...

  • Crestron electronic CEN-TIA - page 29

    Crestron CEN-TIA Telephone Interface Module Reference Documents The latest version of all documents mentioned within the guid e can be obtained from the Crestron website. This link will provid e a list of product manuals arranged in alphabetical or der by model number. List of Related Reference Documents DOCUMENT TITLE 2-Series Control Systems Ref ...

  • Crestron electronic CEN-TIA - page 30

    Telephone Interface Module Crestron CEN-TIA Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandi se may be returned for credit, exchange, or s ervice without prior auth orization from CR ESTRON. To obt ain warranty serv ice for CREST RON products, contact an authorized CRESTRON deal er. Only authorized CRESTRON dealers ...

  • Crestron electronic CEN-TIA - page 31

    Crestron CEN-TIA Telephone Interface Module This page is intentionally left blank. Operations Guide – DOC. 6414 Tele phone Interface Module: CEN-TIA • 27 ...

  • Crestron electronic CEN-TIA - page 32

    Crestron Electronics, Inc. Operations Guide – DOC. 6414 15 Volvo Drive Rockleigh, NJ 07647 (201 3860) Tel: 888.CREST RON 01.07 Fax: 201.76 7.7576 Specif ications subj ect to www.crestron.com change without notice. ...

メーカー Crestron electronic カテゴリー Telephone

Crestron electronic CEN-TIAのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CEN-TIAの取扱説明書
- Crestron electronicの製品カード
- パンフレット
- またはCrestron electronic CEN-TIAの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Crestron electronic CEN-TIAの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Crestron electronic CEN-TIAの取り付け説明書、サービスマニュアル、簡易説明書、またはCrestron electronic CEN-TIAのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Crestron electronic CEN-TIAの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Crestron electronic CEN-TIAデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがCrestron electronic CEN-TIAを使用するのを助ける技術的文書のことです。説明書は通常、全てのCrestron electronic CEN-TIAユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Crestron electronicの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Crestron electronic CEN-TIAの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははCrestron electronic CEN-TIAの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Crestron electronic CEN-TIAに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Crestron electronic CEN-TIAデバイスの基本機能を使うにあたってのヒント。 Crestron electronic CEN-TIAのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Crestron electronic CEN-TIAに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるCrestron electronic CEN-TIAのメーカー/サービスへの連絡先に関する情報。

Crestron electronic CEN-TIAについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもCrestron electronic CEN-TIAの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがCrestron electronic CEN-TIAで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)