  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 1

    INSTRUCTION MANUAL P ART NO. A08200 Rev . 0 Copyright © 2004 Delta Machinery T o learn more about DEL T A MACHINER Y visit our website at: www .deltamachinery .com. For Parts, Service, W arranty or other Assistance, please call 1-866-422-4286. Oil-Fr ee Air Compr essor (Model CP503) ESP AÑOL: PÁGINA 21 FRANÇAIS: P AGE 41 ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 2

    2- ENG A08200 SAFETY GUIDELINES - DEFINITIONS Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, may result in minor ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 3

    3- ENG A08200 IMPOR T ANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all war nings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire How T o Prevent It What Could Happen It is nor ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 4

    4- ENG A08200 WARNING: Risk of Bursting Air T ank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury . How T o Prevent It What Could Happen WARNING: Risk from Flying Objects The compressed air stream can cause soft tissue damage to exposed skin an ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 5

    5- ENG A08200 WARNING: Risk to Breathing WARNING: Risk of Electrical Shock HAZARD HAZARD Y our air compressor is powered by electricity . Like any other electrically powered device, If it is not used properly it may cause electric shock. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution. Electrical Gr ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 6

    6- ENG A08200 WARNING: Risk of Bur ns T ouching exposed metal such as the compressor head or outlet tubes, can result in serious burns. Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation. Do not reach around protective shrouds or attempt maintenance ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 7

    7- ENG A08200 Revie w and unders tand all instructio ns and warnings in this manu al. Becom e famil iar with the oper ation and contr ols of the air comp ress or . Keep operat ing area clear of all persons, pets, and obstacl es. Keep childr en away fr om the air compr essor at all times . Do not operate the produ ct when fatig ued or under the infl ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 8

    8- ENG A08200 Model No. CP503 Running Horsepower 1.5 Bore 1-7/8" Stroke 1-1/4" V olta ge/Hert z/ Phase 120/60/1 Minimum Branch Circuit Requirement 15 amps *Fuse T ype Time Delay Air T ank Capacity 12 gallons Approximate Cut-in Pressur e 100 Approximate Cut-out Pressur e 135 SCFM @ 40 PSIG 4.9 SCFM @ 90 PSIG 3.5 GLOSSAR Y DUTY CYCLE Access ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 9

    INST ALLA TION Location of the Air Compressor Locate the air compr essor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfer e with the flow of air . The air compressor pump and shroud are designed to allow for proper cooling. The ventilation op ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 10

    10- ENG A08200 GROUNDING INSTRUCTIONS RISK OF ELECTRICAL SHOCK. In the event of a short circuit, grounding reduces the risk of shock by pr oviding an escape wire for the electric current. This air compressor must be properly grounded. The portable air compr essor is equipped with a cord having a grounding wire with an appr opriate grounding plug (s ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 11

    11- ENG A08200 V oltage and Circuit Protection Refer to the Parts Manual for the voltage and minimum branch circuit requir ements. Certain air compressors can be operated on a 15 amp circuit if the following conditions are met. 1. V oltage supply through branch circuit is 15 amps. 2. Circuit is not used to supply any other electrical needs (lights, ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 12

    12- ENG A08200 OPERA TION Know Y our Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERA TING YOUR UNIT . Compare the illustrations with your unit to familiarize yourself with the location of various contr ols and adjustments. Save this manual for future refer ence. Description of Operation Become familiar with these contr ols b ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 13

    13- ENG A08200 Before Starting Br eak-in Procedur e Serious damage (for units with a tank) may result if the following break-in instructions are not closely followed. This procedur e is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced. 1. Make sure the On/Auto/Off lever ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 14

    14- ENG A08200 MAINTENANCE Customer Responsibilities Daily or after each use Before each use Check Safety V alve ● D r ai n T a nk ● T o Check Safety V alve If the safety valve does not work properly , over - pressurization may occur , causing air tank rupture or an explosion. Before starting compressor , pull the ring on the safety valve to ma ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 15

    15- ENG A08200 T o Replace or Clean Check V alve 1. Release all air pr essure from air tank. See "T o Drain T ank" in the Maintenance section. 2. Unplug outfit. 3. Loosen the nut on the outlet tube and move the outlet tube to the side. 4. Unscrew the check valve (tur n counterclockwise) using a socket wrench. 5. Make sure the valve disc m ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 16

    16- ENG A08200 T o Replace Regulator 1. Release all air pr essure from air tank. See "T o Drain T ank" in the Maintenance section. 2. Unplug outfit. 3. Using an adjustable wr ench remove the gauges and hose from the regulator . 4. Remove the regulator . 5. Apply pipe sealant tape to the nipple on the standpipe. 6. Assemble the regulator a ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 17

    17- ENG A08200 Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur . Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressur e. PROBLEM CAUSE CORRECTION Pressur e switch does not shut off motor when compress ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 18

    18- ENG A08200 Regulator will not shut off air outlet. Damaged regulator . Replace. PROBLEM CAUSE CORRECTION It is normal for "some" pressur e dr op to occur . If there is an excessive amount of pressur e drop when the accessory is used, adjust the regulator following the instructions in the "Description of Operation" paragraph ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 19

    19- ENG A08200 PROBLEM CAUSE CORRECTION Motor will not run. Check fuse box for blown fuse and replace as necessary . Reset circuit breaker . Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch cir cuit. Check for proper fuse. Y ou should use a time delay fuse. Check for low voltage problem. Check t ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 20

    20- ENG A08200 A08200 LIMITED W ARRANTY DEL T A MACHINERY warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship. Products covered under this warranty include air compressors, air tools, service parts, pressur e washers, and generators, which have the following warranty per ...

メーカー Delta カテゴリー Air Compressor

Delta OIL-FREE AIR COMPRESSOR CP503のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- OIL-FREE AIR COMPRESSOR CP503の取扱説明書
- Deltaの製品カード
- パンフレット
- またはDelta OIL-FREE AIR COMPRESSOR CP503の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Delta OIL-FREE AIR COMPRESSOR CP503の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Delta OIL-FREE AIR COMPRESSOR CP503の取り付け説明書、サービスマニュアル、簡易説明書、またはDelta OIL-FREE AIR COMPRESSOR CP503のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Delta OIL-FREE AIR COMPRESSOR CP503の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Delta OIL-FREE AIR COMPRESSOR CP503デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがDelta OIL-FREE AIR COMPRESSOR CP503を使用するのを助ける技術的文書のことです。説明書は通常、全てのDelta OIL-FREE AIR COMPRESSOR CP503ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Deltaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Delta OIL-FREE AIR COMPRESSOR CP503の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははDelta OIL-FREE AIR COMPRESSOR CP503の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Delta OIL-FREE AIR COMPRESSOR CP503に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Delta OIL-FREE AIR COMPRESSOR CP503デバイスの基本機能を使うにあたってのヒント。 Delta OIL-FREE AIR COMPRESSOR CP503のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Delta OIL-FREE AIR COMPRESSOR CP503に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるDelta OIL-FREE AIR COMPRESSOR CP503のメーカー/サービスへの連絡先に関する情報。

Delta OIL-FREE AIR COMPRESSOR CP503についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもDelta OIL-FREE AIR COMPRESSOR CP503の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがDelta OIL-FREE AIR COMPRESSOR CP503で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)