  • Aprilaire 1750A - page 1

    Model 175 0A / 1 7 7 0A Dehumidifier Installation Instructions READ AND SA VE THESE INSTRUCTIONS CAUTION 1. Read all instructions before beginning installation. 2. Do not use in pool applications. Pool chemicals can damage the dehumidifier . 3. Do not use solvents or cleaners on or near the circuit board. Chemicals can damage circuit board compone ...

  • Aprilaire 1750A - page 2

    OVERVIEW The Aprilaire ® Dehumidifier is designed to control humidity inside the whole home. The dehumidifier uses a dew point calculation to control the humid ity based on the drynes s set point on the dehumidi fier contr ol. An opti onal Model 70 Living Space Contro l or third- party control can be used in place of the onboar d control. The dehu ...

  • Aprilaire 1750A - page 3

    SPECIFICA TIONS Dimensions: 20-3/4”W x 24”L x 20-5/8”H Adjustable feet allow for 22-5/8” total height W eight: 1750A – 93 lbs. 1770A – 100 lbs. Capacity: 1750A – 90 pints per day @ 275 CFM 1770A – 135 pints per day @ 500 CFM AHAM DH-1-2003 80°F , 60%RH conditions Power: 1750A – 115 V AC, 8 A, 15 A circuit 1770A – 115 V AC, 14 A ...

  • Aprilaire 1750A - page 4

    FIGURE 2 – Dimensions and Location Considerations 20-3/4 (527) 24.00 (610) 9-1/2 (241) 10-3/8 (264) 1-1/4 (32) 6-1/2 (165) OFF ON Air Outlet 8 in. Round Collar OFF/ON Switch Drain 2-1/2 (64) 3-7/8 (98) Damper Fully Open Filter Access (Front and Back) Power Cord Air Flow 2-1/2 (64) 20-3/4 (527) 11 (279) 9 (229) 19-5/8 (498) 3 (76) Max. Wiring Acce ...

  • Aprilaire 1750A - page 5

    FIGURE 3 – Install Damper in Collar 90-1503 FIGURE 4 – Install Collar with Damper on Outlet 90-1503 FIGURE 5 – Minimum Ductwork Bend Distance 90-1503 DUCT COLLARS & BACKFLOW DAMPER The backfl ow damper installs on the outlet side of the dehumidifi er , using featur es molded into the duct collar . 1. Remove the duct collars and backflow d ...

  • Aprilaire 1750A - page 6

    FIGURE 6 – Drain Trap 90-961 MECHANICAL INST ALLA TION (CONTINUED) DRAIN 1. Adjust feet of dehumi difie r to allow a 2-1/2” minimum clearance for drain trap. See Figure 6 . Use the 90° elbow if necessa ry for clearance restrictions. See Figure 7 . 2. Use PVC primer and cement for drain assembly to the dehumidifi er drain outlet. 3. Complete as ...

  • Aprilaire 1750A - page 7

    WHOLE-HOME INST ALLA TION (CONTINUED) FIGURE 9 – Whole-Home Basement Installation CONDENSA TE HOSE (TO COMMON DRAIN OR OUTSIDE) AIR IS PULLED FROM RETURN DUCT DEHUMIDIFIED AIR IS SUPPLIED DOWNSTREAM FROM A-COIL TO MINIMIZE EV APORA TION OFF A-COIL A-COIL RETURN DUCT SUPP LY DUCT DEHUMIDIFIER 115 VA C CIRCUIT HV AC / FURNACE FLOOR DRAIN FIGURE 10 ...

  • Aprilaire 1750A - page 8

    WHOLE-HOME INST ALLA TION (CONTINUED) •  HV ACFAN ON:Activatin gtheHV AC fan  during dehumidi ficat ionis recomm ended because it offers bett er circul ation and balancing of indoor air conditions. Running the HV AC fan during dehumidification does not affect moisture removal efficiency . If the switch is put i ...

  • Aprilaire 1750A - page 9

    SPOT INST ALLA TION (CONTINUED) FIGURE 14 – Spot Ducted Installation OUTSIDE AIR TO HOUSE LIVING SP ACE SUPPL Y DUCT RETURN DUCT FLOOR DRAIN DEHUMIDIFIER 115 VA C CIRCUIT EQUIPMENT ROOM CONDENS AT E HOSE (TO COMMON DRAIN OR OUTSIDE) HV AC FURNACE DEHUMIDIFIED AIR IS SUPPLIED TO DUCTED SP ACE AIR IS PULLED FROM AREA GRILLE WITH 8" DUCT COLLAR ...

  • Aprilaire 1750A - page 10

    CONVERTIBLE INST ALLA TION In this installation the dehumidifier controls humidity in both the whole- home and a spot locatio n. The dehu midif ier will dehumidify the whole home as the first priority , switching to the spot location after the whole-home dehumidification need has been met. Duct ing the unit to the return and suppl y , where air is ...

  • Aprilaire 1750A - page 11

    CONVERTIBLE INST ALLA TION (CONTINUED) •  HV ACFAN ON:Activatin gtheHV AC fan  during Whole-Ho medehumid ifica tion is recomme nded beca use it offers bette r circu latio n and balancin g of indoor air condit ions. Running the HV AC fan during dehumi dific ation does not affect moistu re remo val effic iency . ...

  • Aprilaire 1750A - page 12

    VENTILA TION OR AIR CYCLING The dehumi difie r has outputs avai lable to open a norm ally clos ed damper and introd uce out door air thoug h an outdoo r air intake duct. V entilat ion is cont rolle d by the Cycle Period switches, Cycle T ime potentiometer , and V ent-Auto/Vent-T imed switches. If a normally closed ventilation damper is not installe ...

  • Aprilaire 1750A - page 13

    VENTILA TION OR AIR CYCLING (CONTINUED) DETERMINE FRESH AIR DELIVERY RATE 1. Measure the negative static pressure of the return system at the location where the outdoor air duct enters the return duct. 2. See T able 4 for estimated inlet airflow in CFM, based on duct type, length, and available negative pressure. Use an airflow measuring device for ...

  • Aprilaire 1750A - page 14

    VENTILA TION OR AIR CYCLING (CONTINUED) Switch Notes: •  Setting theCycle T ime ≥ Cycle Period will result in constant ventilation. •  Setting theCycle T imeto OFF willdisable ventilation. 1. Set VENT -AUTO and VENT -TI MED switch . VENT -AUTO restricts ventil ation based on outdoor tempe rature ...

  • Aprilaire 1750A - page 15

    VENTILA TION OR AIR CYCLING (CONTINUED) SEQUENCE OF OPERATION VENT-TIMED, HVAC INITIATES VENTILATION •  V entilat ionwilloccur  whenev erthereisanHV ACfan (Gs )orheat(W)callandwillcontinue  untiltheventi lationtimehasmetthesetCycle T ime during the set Cycle Perio ...

  • Aprilaire 1750A - page 16

    MODEL 70 LIVING SP ACE CONTROL WIRING & DIP SWITCH CONFIGURATION TheModel 70 LivingSpace Controlcontains itsown sensorsthat override themain controlsensors onthe dehumidifier . Thepurpose ofutilizing  the Model 70 is to have the dehumidi fier contr ol locate d in a liv ing are ...

  • Aprilaire 1750A - page 17

    THIRD-P ARTY CONTROL WIRING & DIP SWITCH CONFIGURATION An externa l thermos tat with dehum idifi er connect ions can be used as an ON/ OFF dehumi difier control. In this configura tion, the third-par ty control initiates dehumidification and overrides the on-board dehumidifier control logic. The dehumidifier control knob can only be used to ini ...

  • Aprilaire 1750A - page 18

    SYSTEM CHECKOUT DEHUMIDIFICATION 1. Check the wiring to the HVAC equipment and any accessories if applicable. 2. Plug unit in and turn on/off switch to ON. 3. Rotate the main control knob clockwise to the TEST position. 4. If set up cor rectl y , the dehumidi fier blow er will turn on and the dehumidi fier damp er output will turn on. After 30 seco ...

  • Aprilaire 1750A - page 19

    TROUBLESHOOTING T ABLE 7 – Green LED Codes Activity Status Solid ON Compressor ON Blinking 1 sec. ON & 1 sec. OFF Sampling Blinking 1/2 sec. ON & 1/2 sec. OFF Defrosting Alternating Green & Red T est Mode T echnical Support is available Monday through Friday , 7:00 a.m. to 5:00 p.m. CST , at (800) 334-6011. Use the guides on the follo ...

  • Aprilaire 1750A - page 20

    T ABLE 9 – T roubleshooting Guide Symptom Possible Reason T roubleshooting Procedure Dehumi difier does not turn on/run. No power to unit. • Check thatthe dehumidifieris pluggedin. • Check thatthe powerswitch onthe dehumidifieris ON. • Check thatcontrol knobis set ...

メーカー Aprilaire カテゴリー Dehumidifier

Aprilaire 1750Aのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 1750Aの取扱説明書
- Aprilaireの製品カード
- パンフレット
- またはAprilaire 1750Aの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Aprilaire 1750Aの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Aprilaire 1750Aの取り付け説明書、サービスマニュアル、簡易説明書、またはAprilaire 1750Aのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Aprilaire 1750Aの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Aprilaire 1750Aデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAprilaire 1750Aを使用するのを助ける技術的文書のことです。説明書は通常、全てのAprilaire 1750Aユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Aprilaireの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Aprilaire 1750Aの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAprilaire 1750Aの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Aprilaire 1750Aに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Aprilaire 1750Aデバイスの基本機能を使うにあたってのヒント。 Aprilaire 1750Aのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Aprilaire 1750Aに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAprilaire 1750Aのメーカー/サービスへの連絡先に関する情報。

Aprilaire 1750Aについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAprilaire 1750Aの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAprilaire 1750Aで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)