    TORNADO INDUSTRIES 7401 W. LAWRENCE AVENUE CHICAGO, IL 60706 (708) 867-5100 FAX (708) 867-6968 www.tornadovac.com Tornado £ Operation & Maintenance Manual For Commercial Use Only Marathon 2000 Forward Only Extractor CATALOG NO. 98190 (115V, 60 HZ) For parts list see L8190GHP Effective 12/19/2005 L8190GH Revised 12/05 ¤ 2006 Tornado Industries ...

  • Tornado 98190 - page 2

    2 NOTES ...

  • Tornado 98190 - page 3

    3 Write your machine’s serial number here:_________________________________ This illustrated instruction book covers: CATALOG NO. 98190 SERIES H SIZE 22” CAPACITY 20 Gal. VOLTS 115V AMPS 15 All specifications are subject to change without notice. TABLE OF CONTENTS: Warranty 4 Safety Instructions 5 Preparation & General Precautions 6 Cleanin ...

  • Tornado 98190 - page 4

    4 Thank you for choosing Tornado products. We are proud to offer the most complete line of commercial and industrial cleaning equipment in the industry. Our reputation for quality, innovation and durability is unsurpassed. * Effective Januar y 1 st , 2005. Terms subject t o change without notice. 1) Windshear™ Blower-Dryer, I nsulation Blowers, T ...

  • Tornado 98190 - page 5

    5 IMPORTANT SAFETY INSTRUCTIONS FOR COMMERCIAL USE WHEN USING AN ELECTRICAL APPLIANCE, BASIC PRECAUTIONS SHOUL D ALWAYS BE FOLLOWED INCLUDING THE FOLLOWING: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY: 1. Do not leave machine when plugged in. Unplug from outlet when not in use and b ...

  • Tornado 98190 - page 6

    6 SAVE THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE Read the manual carefully and completely before attempting to operate the unit. This manual has important information for the use and safe operation of the machine. Keep this manual on file and handy. This machine will assure years of satisfactory service if operated and maintained according to ...

  • Tornado 98190 - page 7

    7 GENERAL PRECAUTIONS x Make sure the machine is plugged into an electrical outlet with the same voltage and frequency rating as shown on the nameplate of the machine. Do not attempt to plug a 115-volt machine in a 230-volt outlet. x Disconnect power cord from the outlet before attempting maintenance or repair work. Do not leave machine connected t ...

  • Tornado 98190 - page 8

    8 ELECTRICAL This machine operates on a standard, 15 AMP, 115 volt AC circuit and has a grounded plug.* Make sure the machine is connected to an outlet having the same configuration as the plug. No ungrounded adapter should be used with this machine. * Special voltage models available. GROUNDING INSTRUCTIONS This machine must be grounded. If it sho ...

  • Tornado 98190 - page 9

    9 Sketch A S ketch B Sketch C STRAIN RELIEF Attaching the strain relief/cord retainer to the 50’ power cord. 1. Make a loop in power cord approximately 12” from receptacle end. 2. Slide cord loop through slot in retainer and over retainer arm. Pull slack cord back through slot to secure. Attach re tainer to handle. EXTENSION CORD If an extensio ...

  • Tornado 98190 - page 10

    10 CLEANING TIPS x Check the condition of the carpeting. If the carpet is loose, heavily soiled, stained, spotted or badly worn, point this out to the person in charge. x Locate an inconspicuous spot on the area to be cleaned. Test carpet for colorfastness before proceeding. Pour the concentrated cleaning solution on the spot, cover with a white to ...

  • Tornado 98190 - page 11

    11 MACHINE SPECIFICATIONS Q ELECTRICAL: 115 V, 15 A, 60 HZ. Q DURABLE EXTENSION CORD: 75 ’ Q DRIVE SYSTEM: TRANSAXLE W/ VARIABLE SPEED, (0-100 FT/MIN) Q VACUUM MOTOR: 3 STAGE, 1 HP., 120 CFM Q VACUUM SHOE: 22” WIDE, CAST AL UMINUM, ADJUSTABLE, FLOATING ARM Q BRUSH: 19” LONG Q BRUSH SPEED /HP: 1000 RPM / 1/4 HP Q SOLUTION PUMP: 100 PSI, DIAPHR ...

  • Tornado 98190 - page 12

    12 OPERATION INSTRUCTIONS Main Controls: Your Marathon 2000 extractor is equipped with (4) main switches, which control the spray bar, the brush motor, the vacuum motor and the main power. The main switch must be activated before operating the transaxle drive. The machine will glide easily across the floor when pushed forward (without power). The m ...

  • Tornado 98190 - page 13

    13 Set Up and Operation: Your Marathon 2000 is shipped complete and ready for carpet cleaning. This style of machine is sometimes referred to as a self-contained extractor, since everything is included in the body of the Marathon 2000 extractor. 1. Install recovery tank cover to the top of the tank and connect the suction hose to the cover. 2. Impo ...

  • Tornado 98190 - page 14

    14 15. While cleaning, pre-spray traffic areas and spots using the spray wand. The spray wand is attached to a quick disconnect and is pressurized when the MAIN SWITCH is turned on. WARNING: To avoid serious injury: Disconnect power before servicing. Electrical service must be performed by an authorized service station or electrician. Use only nonf ...

  • Tornado 98190 - page 15

    15 x Be sure to use Tornado genuine parts and service is provided by an authorized Tornado Service Center. Use of non-O.E.M. parts will void the warranty. PROTECT FROM FREEZING - Caution! If it becomes necessary to store in temperatures that could drop below 40 degrees F, the pumping system, hoses and valves must be protected from freezing with a m ...

  • Tornado 98190 - page 16

    16 Troubleshooting Table: Problem Solution No Power, Nothing Works * Plug in Cord, Check Circuit Breakers * Activate Main Power Switch * Check For Loose Wiring * Call Service Machine Will Not Move Forward * Reset Circuit Breaker * Turn Speed Control Knob Clockwise * Call Service Brush Does Not Rotate * Reset Circuit Breaker * Activate Brush Switch ...

メーカー Tornado カテゴリー Vacuum Cleaner

Tornado 98190のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 98190の取扱説明書
- Tornadoの製品カード
- パンフレット
- またはTornado 98190の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Tornado 98190の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Tornado 98190の取り付け説明書、サービスマニュアル、簡易説明書、またはTornado 98190のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Tornado 98190の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Tornado 98190デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがTornado 98190を使用するのを助ける技術的文書のことです。説明書は通常、全てのTornado 98190ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Tornadoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Tornado 98190の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははTornado 98190の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Tornado 98190に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Tornado 98190デバイスの基本機能を使うにあたってのヒント。 Tornado 98190のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Tornado 98190に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるTornado 98190のメーカー/サービスへの連絡先に関する情報。

Tornado 98190についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもTornado 98190の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがTornado 98190で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)