    AU182XFERA R410A MUL TI SPLIT SERIES ROOM AIR CONDITIONER OUTDOOR UNIT INST ALLA TION MANUAL AU222XFERA Please read this manual carefully before installing the units. Please keep this manual safely for future use. NO.0010576791B ...

  • Haier AU182XFERA - page 2

    Cautions ....................................................................................................................... Safety precautions........................................................................................................ Installation accessories.......................................................................... ...

  • Haier AU182XFERA - page 3

    Cautions 1 Disposal of the old air conditioner Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The v ...

  • Haier AU182XFERA - page 4

    4. The wiring method should be in line with the local wiring standard. 5. The power cable and connecting cable are self- provided. The requirement of the power cable to the outdoor unit: H05RN-F 3G 4.0mm 2 All the cables shall have got the local authentication certificate. 6. The breaker of the air conditioner should be all- pole switch; and the di ...

  • Haier AU182XFERA - page 5

    3 Safety pr ecautions All units shall be earthed. The earth must not be connected to a gas pipe, water pipe, or telephone line. Poor earthing could cause electric shock. Be sure to install a circuit breaker to avoid electric shock. Arrange water drainage according to this manual. Cover pipe with insulation materials to prevent condensation occuring ...

  • Haier AU182XFERA - page 6

    4 (c) Where there is strong radiation. It will affect the unit's control system, causing malfunction of the unit. (d) Where there are flammable gas, dirt, and volatile matter (thinner , gasoline) exist, these items will cause a fire risk. The following accessories are supplied together with the outdoor unit. 113.5 583 319.5 680 113.5 Installat ...

  • Haier AU182XFERA - page 7

    5 1. Do not connected the embedded branch piping and the outdoor unit when only carrying out piping work without connecting the indoor unit in ordor to add another indoor unit later . Make sure no dirt or mositure gets into eigher side of the embedded branch piping. 2.It is impossible to connect the indoor unit for one room only . Be sure to connec ...

  • Haier AU182XFERA - page 8

    6 Matching of the indoor and outdoor units Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponded name plate. Install an exclusive branch circuit of the power . A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it ...

  • Haier AU182XFERA - page 9

    7 L1 L2 L3 h H + A B C H - The piping length information, please refer the following table. Descriptions Standard A, B, Cliquid pipe A, B, C Gas pipe mm Item Maximum Unit L1 (one way) L2 (one way) L3 (one way) h H + H - mm m m m m m m Size of the liquid side connection pipe Pipe length when the compressor connects with two indoor units Drop between ...

  • Haier AU182XFERA - page 10

    8 Refrigerant piping work Forced fastening without careful centering may damage the threads and cause a leakage of gas. Pipe Diameter ( ) Fastening T orque Liquid Side 6.35mm (1/4'') 18N.m Gas Side 9.52mm (3/8'') 50N.m 3. Attaching Drain-Elbow Drain elbow Hose If the drain-elbow is used, please attach it as figure. Flare nut Hal ...

  • Haier AU182XFERA - page 11

    9 4.Cutting and Flaring work of piping Pipe cutting is carried out with a pipe cutter and burs must be removed. After inserting the flare nut, flaring work is carried out. Less than 5cm It becomes high midway . The end is immersed in water It waves. It gap with the ground ts too small. There is the bad smell from a ditch. Please pour water in the d ...

  • Haier AU182XFERA - page 12

    10 In case of gas leakage, tighten parts of pipe connection. If leakage stops, then proceed 6 steps. Purging method: to use vacuum pump 2 way valve 3 way valve 90 0 Service port 90 0 for 6 sec. 6 .Detach the charge hose from the service port, open 2- way valve and 3-way . T urn the valve rod anticlockwise until hitting lightly . Liquid stop valve 2 ...

  • Haier AU182XFERA - page 13

    1. Electric wiring Note: The air conditioner must use special circuit , and wiring by the qualified electrician according to the wiring rules specified in national standard. The grounding wire and the neutral wire shall be strictly separated. Connect the neutral wire with grounding wire is incorrect. The electric leakage breaker must be installed. ...

  • Haier AU182XFERA - page 14

    12 3. W iring method of outdoor unit: Loosen wire cover and connect the power line and communication wire of indoor unit to the terminal correspondingly . Note: When connecting power line to power supply terminal, please pay attention to the following items: Do not connect the power line with different dimensions to the same connection wire end. Im ...

  • Haier AU182XFERA - page 15

    13 The distance between the signal wires and the power cabes should be at least 50mm. C B A Q P 1(L) 2(N) 5. Example wiring diagram. Please refer to the indoor unit installation manual to find detailly how to set and check the communication address. Incorrect address setting will cause abnormal to the system. 6. After installation, please fill in t ...

  • Haier AU182XFERA - page 16

    14 Items to confirm T est running Before starting the test running, please confirm the following works have been done successfully . 1) Correct piping work; 2) Correct wiring work; 3) Correct match of indoor and outdoor unit; 4) Proper recharge of refrigerant if needed; 5)Correct indoor unit addresses setting. Make sure that all the stop valves are ...

  • Haier AU182XFERA - page 17

    15 F AILURE CODE ST A TE OF LED 5-4-3-2-1 TROUBLE SHOOTING POSSIBLE REASONS 1 Faulty defrost sensor T e Sensor disconnected, or broken, or short circuit Faulty sensor T ao Sensor disconnected, or broken, or short circuit Faulty sensor T s Sensor disconnected, or broken, or short circuit Faulty sensor Td Sensor disconnected, or broken, or short circ ...

  • Haier AU182XFERA - page 18

    HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden, Qianwangang Road, Economic Development Zone, Qingdao, Shandong 266500, P .R.China W eb Site: http://www .haier .com ...

メーカー Haier カテゴリー Air Conditioner

Haier AU182XFERAのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AU182XFERAの取扱説明書
- Haierの製品カード
- パンフレット
- またはHaier AU182XFERAの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Haier AU182XFERAの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Haier AU182XFERAの取り付け説明書、サービスマニュアル、簡易説明書、またはHaier AU182XFERAのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Haier AU182XFERAの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Haier AU182XFERAデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHaier AU182XFERAを使用するのを助ける技術的文書のことです。説明書は通常、全てのHaier AU182XFERAユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Haierの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Haier AU182XFERAの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHaier AU182XFERAの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Haier AU182XFERAに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Haier AU182XFERAデバイスの基本機能を使うにあたってのヒント。 Haier AU182XFERAのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Haier AU182XFERAに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHaier AU182XFERAのメーカー/サービスへの連絡先に関する情報。

Haier AU182XFERAについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHaier AU182XFERAの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHaier AU182XFERAで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)