Quadra-Fire 3100-Iの取扱説明書

28ページ 2.13 mb
ダウンロード

ページに移動 of 28

Summary
  • Quadra-Fire 3100-I - page 1

    R DO NOT DISCARD THIS MANUAL CAUTION • Important operating and maintenance instructions included. • Leave this manual with party responsible for use and operation. HOT SURF ACES! Glass and other surfaces are hot during operation AND cool down. W ARNING Hot glass will cause burns. • Do not touch glass until it is cooled • NEVER allow childre ...

  • Quadra-Fire 3100-I - page 2

    3100-I ACT WOOD INSERT Page 2 September 1, 2008 R 250-6381D and Welcome to the Quadra-Fire Family ! H earth & Home T echnologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality , durability , and performance. This commitment begins with our research of the market, ...

  • Quadra-Fire 3100-I - page 3

    Page 3 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D SAFETY & OVER VIEW OF APPLIANCE Serial Number /Listing Label Location ------------------ 2 Dimensions ----------------------------------------------------- 4 Minimum Clearances to Combustibles ------------------ 5 Installation Recommendations ---------------------------- 6 Listings & ...

  • Quadra-Fire 3100-I - page 4

    3100-I ACT WOOD INSERT Page 4 September 1, 2008 R 250-6381D INSERT DIMENSIONS T OP VIEW SIDE VIEW FRONT VIEW A B C L 27-7/16" (697mm) 14-1/8" (359mm) 38-7/8" (987mm) 12-3/16" (310mm) 8-5/8" (219mm) 5-3/8" (137mm) 22-7/16" (570mm) 23-1/8" (587mm) 21-1/2" (546mm) 20-3/8" (518mm) 26-1/4" (667mm) 7 ...

  • Quadra-Fire 3100-I - page 5

    Page 5 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D Hearth Extension A B C D F E Insert SideW all Maximum Mantel Depth - 10" (254mm) Fascia or T rim Mantel Thermal Protection USA & Canada USA CANADA A Sidewall to Stove 16" 16" (406mm) B Mantel Clearances *No Mantel Shield 33" 34" (864mm) with 5" Mantel Defle ...

  • Quadra-Fire 3100-I - page 6

    3100-I ACT WOOD INSERT Page 6 September 1, 2008 R 250-6381D A VOID FIRE: T o ensure that insulation or any other combustible material does not contact the chimney , a chimney inside the house must have at least 2 inches (51mm) of air space clearance around t he chimney . A chimney outside the house must have at least 1 inch (25mm) clearance to the ...

  • Quadra-Fire 3100-I - page 7

    Page 7 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D IF INST ALLING THIS MODEL TO A MASONR Y CHIMNEY , AL W A YS BE SURE THE CHIMNEY IS IN GOOD CONDITION AND THA T IT MEETS THE MINIMUM ST ANDARDS OF THE NA TIONAL FIRE PROTECTION ASSOCIA TION (NFP A) ST ANDARD 21 1. A F ACTOR Y BUIL T CHIMNEY MUST BE 6 INCH (152mm) UL 103 HT AND ULC S629. THIS ...

  • Quadra-Fire 3100-I - page 8

    3100-I ACT WOOD INSERT Page 8 September 1, 2008 R 250-6381D Floor Ceiling Caulk Floor (second Story) Non-Combustible Firestopping Material Minimum 1 inch (25mm) clearance from exterior chimney to sheathing Firestopping 2 inch (51mm ) A chimney must be the required height above the roof or other obstruction for safety and for proper draft oper - ati ...

  • Quadra-Fire 3100-I - page 9

    Page 9 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D MASONR Y FIREPLACE USING DIRECT -CONNECT METHOD Refer to: Clearances to Combustibles on page 5, Canadian Installation requirements on page 1 1, Hearth Requirements on page 5 and Zero Clearance Adjustable Support Kit on page 14. Figure 9A - Installation Into Masonry Fireplace Direct Connect ...

  • Quadra-Fire 3100-I - page 10

    3100-I ACT WOOD INSERT Page 10 September 1, 2008 R 250-6381D The following modications of factory built replaces are permissible: 1) removal of damper; 2) removal of smoke shelf or bafe; 3) removal of ember catches; 4) removal of re grate; 5) removal of viewing screen/curtain; and, 6) removal of doors. NOTE: Installation into replace ...

  • Quadra-Fire 3100-I - page 11

    Page 1 1 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D INST ALLA TION IN CANADA MASONR Y and HEA T -CIRCULA TING (INST ALLA TIONS INTO F ACTORY -BUIL T FIREPLACES ARE PROHIBITED IN CANADA) Whether installed in a masonry or heat-circulating replace, this replace insert must be installed with a continuous chim- ney liner of 6” (152mm) d ...

  • Quadra-Fire 3100-I - page 12

    3100-I ACT WOOD INSERT Page 12 September 1, 2008 R 250-6381D Vi ew of "L" Bracket installed Kit Includes: ( 2) Side Panels, left & right; (1) Panel T op & Fastener package; (2) Side T rim, left & right; (1) T rim T op & Fastener package. T ools Needed: Powered Phillips head screw driver . 1. Install the 2 side panels on th ...

  • Quadra-Fire 3100-I - page 13

    Page 13 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D Included in Kit: (2) Fan mounts & fan assemblies; (1) Speed Control, Power Cord/wire assembly; (1 set) Fan Connector wires, must be high temperature wire; and (1) Strain relief. T ools Needed: Large Phillips screwdriver , pliers F AN (BLOWER) INST ALLA TION INSTRUCTIONS Part No. 831-1 ...

  • Quadra-Fire 3100-I - page 14

    3100-I ACT WOOD INSERT Page 14 September 1, 2008 R 250-6381D ZERO CLEARANCE ADJUST ABLE TRIM SUPPORT , 2” to 10” Part No. 841-0990, size 9” x 45” and Part No. ADJSPT -12, size 12” x 50” Included in Kit: ( 1) T rim T op, (1) T rim Front, (2) T rim Sides, Double-Sided T ape (already installed) T ools Needed: Phillips Head Screwdriver , Sh ...

  • Quadra-Fire 3100-I - page 15

    Page 15 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D WOOD SELECTION AND STORAGE Burn only dry seasoned wood. Dry , well-seasoned wood will not only minimize the chance of creosote formation but will give you the most efcient heat output. Even dry wood contains at least 15% moisture by weight and should be burned hot enough to keep the chi ...

  • Quadra-Fire 3100-I - page 16

    3100-I ACT WOOD INSERT Page 16 September 1, 2008 R 250-6381D BURN RA TES ST ARTING FIRE : Open both controls (push in) completely . After a wood load has been burning on high for 5 to 15 minutes or longer for very large pieces, close the Start-Up Air Control (right side) by pulling it out. HIGH: Leave the Primary Air Control fully open (immediately ...

  • Quadra-Fire 3100-I - page 17

    Page 17 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D AIR qUALITY AND YOUR qUADRA-FIRE INSERT In recent years there has been an increasing concern about the quality of our air . Much of the blame for poor air quality has been placed on the burning of wood for home heating. In order to improve this situation we at Quadra-Fire have developed cl ...

  • Quadra-Fire 3100-I - page 18

    3100-I ACT WOOD INSERT Page 18 September 1, 2008 R 250-6381D MAINTENANCE CARE AND CLEANING OF PLA TED SURF ACES IMPORT ANT : Y ou must clean all the ngerprints and oils from the plated surfaces before ring the insert for the rst time. Use warm soapy water and a soft rag, glass cleaner and a paper towel, or vinegar and a paper towel to remo ...

  • Quadra-Fire 3100-I - page 19

    Page 19 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D BAFFLE REMOV AL & INST ALLA TION NOTE : The bafe in the 3100-I ACT Insert is 2700° Fiber Board. Removing hardware exposed to combustion processes can be frustrating. If your reason for removing the bafe is simply to clean the chimney , you have alternatives which will save time ...

  • Quadra-Fire 3100-I - page 20

    3100-I ACT WOOD INSERT Page 20 September 1, 2008 R 250-6381D EXPLODED VIEW 1 9 10 11 2 4 3 8 6 7 5 Item Description Item Description 1 T rim Ring, Louver 7 Screen, Left/Right (interchange - able) 2 Manifold T ubes, Back (3) 8 Speed Control 3 Manifold T ube, Front (1) 9 Bafe, Fiberboard 4 Spring Handle, 1/4” (2) 10 Blanket, Ceramic 5 Blower Ass ...

  • Quadra-Fire 3100-I - page 21

    Page 21 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D Item # Part Description Alphabetical Order SKU 9 Bafe, Fiberboard 831-1800 10 Blanket, Ceramic, 1 inch thick 832-3401 Blower Assembly , with Wire Harness 831-1 101 Blower Cord with Speed Control & Wire Harness 832-1400 5 Blower Assembly 831-1 101 Blower Replacement (1) 832-3190 1 1 ...

  • Quadra-Fire 3100-I - page 22

    3100-I ACT WOOD INSERT Page 22 September 1, 2008 R 250-6381D 1 T rim Ring for Louver, Gold 430-2691 1 T rim Ring for Louver, Nickel 430-5430 Upgrade Kit to Nickel, Door UK-DRNL 14 W asher, Spacing SAE 3/8 for Door Handle 220-0010 Item # Part Description Alphabetical Order SKU ACCESSORIES 15 16 17 18 19 20 21 22 12 13 14 Item Description Part No. 12 ...

  • Quadra-Fire 3100-I - page 23

    Page 23 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D Date of Service Performed By Description of Service Service And Maintenance Log ...

  • Quadra-Fire 3100-I - page 24

    3100-I ACT WOOD INSERT Page 24 September 1, 2008 R 250-6381D Date of Service Performed By Description of Service Service And Maintenance Log (Cont’d) ...

  • Quadra-Fire 3100-I - page 25

    Page 25 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D Homeowner ’ s Notes ...

  • Quadra-Fire 3100-I - page 26

    3100-I ACT WOOD INSERT Page 26 September 1, 2008 R 250-6381D W arranty Policy Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased from an authorized HHT dealer and installed in the United Sta ...

  • Quadra-Fire 3100-I - page 27

    Page 27 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D  HHT’s obligation under this warranty does not extend to damages resulting from: (1) installation, operation or main- tenance of the appliance not in accordance with the installation instructions; operating instructions and the listing agent identication label furnished with the ...

  • Quadra-Fire 3100-I - page 28

    Page 28 September 1, 2008 250-6381D R • Do NOT discard this manual. • Important operating and maintenance instructions included. • Read, understand and follow these instruci- tons for safe installation and operation. • Leave this manual with party responsible for use and operation. CAUTION This product may be covered by one or more of the f ...

メーカー Quadra-Fire カテゴリー Indoor Fireplace

Quadra-Fire 3100-Iのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 3100-Iの取扱説明書
- Quadra-Fireの製品カード
- パンフレット
- またはQuadra-Fire 3100-Iの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Quadra-Fire 3100-Iの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Quadra-Fire 3100-Iの取り付け説明書、サービスマニュアル、簡易説明書、またはQuadra-Fire 3100-Iのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Quadra-Fire 3100-Iの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Quadra-Fire 3100-Iデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがQuadra-Fire 3100-Iを使用するのを助ける技術的文書のことです。説明書は通常、全てのQuadra-Fire 3100-Iユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Quadra-Fireの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Quadra-Fire 3100-Iの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははQuadra-Fire 3100-Iの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Quadra-Fire 3100-Iに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Quadra-Fire 3100-Iデバイスの基本機能を使うにあたってのヒント。 Quadra-Fire 3100-Iのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Quadra-Fire 3100-Iに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるQuadra-Fire 3100-Iのメーカー/サービスへの連絡先に関する情報。

Quadra-Fire 3100-Iについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもQuadra-Fire 3100-Iの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがQuadra-Fire 3100-Iで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)