    Installation Manual MMI-20020994, Rev AA December 2013 Micro Motion ® Fork Viscosity Meters Direct insertion viscosity meter installation ...

  • Emerson Micro Motion Fork Viscosity Meters - page 2

    Safety and approval information This Micro Motion product complies with all applicable European directives when properly installed in accordance with the instructions in this manual. Refer to the EC declaration of conformity for directives that apply to this product. The EC declaration of conformity, with all applicable European directives, and the ...

  • Emerson Micro Motion Fork Viscosity Meters - page 3

    Contents Chapter 1 Planning ........................................................................................................................... 1 1.1 Installation checklist ........................................................................................................................1 1.2 Best practices ............................ ...

  • Emerson Micro Motion Fork Viscosity Meters - page 4

    Contents ii Micro Motion Fork Viscosity Meter ...

  • Emerson Micro Motion Fork Viscosity Meters - page 5

    1 Planning Topics covered in this chapter: • Installation checklist • Best practices • Power requirements • Other installation considerations • Recommended installations for short-stem meters • Perform a meter check (pre-installation) 1.1 Installation checklist □ Verify the contents of the product shipment to confirm you have all part ...

  • Emerson Micro Motion Fork Viscosity Meters - page 6

    1.2 Best practices The following information can help you get the most from your meter. • Handle the meter with care. Follow local practices for lifting or moving the meter. • Perform a Known Density Verification (KDV) check of the meter prior to installing the meter in your system. • For the PFA-coated tines, always fit the protective cover ...

  • Emerson Micro Motion Fork Viscosity Meters - page 7

    Power cable recommendations for explosion-proof/flameproof meters Minimum wire gauge (AWG per feet) Figure 1-1: 300 600 900 1200 150 0 1800 2100 2400 2700 300 0 Dis t anc e of I nst all a t ion (f t) 21 .6V 24 V 14 15 16 17 18 19 20 21 22 23 24 25 26 AWG Maximum Minimum W ire Gauge Minimum wire area (mm 2 per meter) Figure 1-2: 0.00 0 0.05 0 0.10 0 ...

  • Emerson Micro Motion Fork Viscosity Meters - page 8

    1.4 Other installation considerations A variety of external factors exist that affect the ability of the meter to operate successfully. To ensure that your system works correctly, consider the effects of these factors when designing your installation. 1.4.1 Calibration boundaries Important Micro Motion calibrates all meters at the factory according ...

  • Emerson Micro Motion Fork Viscosity Meters - page 9

    Region of measurement boundary or sensitivity Figure 1-3: B A C STATUS SCROLL SELECT A. Long axis B. Short axis C. Sensitive, or effective, region When installing the meter, if part of this effective region or volume is interfered with because of the pipework or fittings a boundary effect exists (see Figure 1-4 ). Planning Installation Manual 5 ...

  • Emerson Micro Motion Fork Viscosity Meters - page 10

    Example of pipeline installation (with boundary effect) Figure 1-4: A STATUS SCROLL SELECT A. Pipe walls interrupt effective region of meter sensitivity 1.4.2 Flow rate considerations You must maintain flow rates and velocities to be relatively constant within the limits specified for the meter. The fluid flow provides a steady heat flow into the m ...

  • Emerson Micro Motion Fork Viscosity Meters - page 11

    • Maintain a back pressure on the system sufficient to prevent gas break out. • Maintain flow velocity at the sensor within the specified limits. 1.4.4 Solids measurement considerations Consider the following to avoid issues related to solids contamination: • Avoid sudden changes of the fluid velocity that may cause sedimentation. • Install ...

  • Emerson Micro Motion Fork Viscosity Meters - page 12

    Standard installation types: short-stem meters Table 1-1: Installation type: Free stream T-Piece Flow-through chamber Meter placement Meter tines are inserted directly into the main fluid flow. The meter must always be installed horizontally and with the tines oriented to allow flow through or between the gap of the tines. Meter tines are contained ...

  • Emerson Micro Motion Fork Viscosity Meters - page 13

    Standard installation types: short-stem meters (continued) Table 1-1: Installation type: Free stream T-Piece Flow-through chamber Recommendations Do not use with: • Dirty fluids • Low or unstable flow rates • Where step changes in viscosity can occur • For small bore pipes Do not use with: • Dirty fluids • Low or unstable flow rates • ...

  • Emerson Micro Motion Fork Viscosity Meters - page 14

    Power supply wiring terminals Figure 1-5: A A. 24 VDC 4. Perform a Known Density Verification (KDV) check. The Known Density Verification procedure is used to verify that the meter's current operation matches the factory calibration. If the meter passes the test, then it has not drifted or changed since its factory calibration. For more inform ...

  • Emerson Micro Motion Fork Viscosity Meters - page 15

    2 Mounting Topics covered in this chapter: • Mount in free-stream application (flanged fitting) • Mount in free-stream application (weldolet fitting) • Mount with a T-piece (flanged fitting) • Mount with a flow-through chamber • Mount in an open tank (long-stem meter) • Mount in a closed tank (long-stem meter) • Attach the PFA ring an ...

  • Emerson Micro Motion Fork Viscosity Meters - page 16

    Free-stream (flanged fitting) meter installation Figure 2-1: B A STATUS SCROLL SELECT Plan view of a vertical pipe installation A. 4-inch pipe for horizontal installations; 6-inch (152 mm) pipe for vertical installations B. Size the recess mount so that the meter tines are inserted fully into the liquid [approximately 2.75 in (70 mm)]. 2.2 Mount in ...

  • Emerson Micro Motion Fork Viscosity Meters - page 17

    Procedure See Figure 2-2 for information on installing the meter (with a weldolet fitting) in a free- stream application. Important You must always install the meter horizontally and oriented to allow flow in the gap between the tines, irrespective of the pipeline orientation (horizontal or vertical). This position helps to prevent the trapping of ...

  • Emerson Micro Motion Fork Viscosity Meters - page 18

    Note - Flow velocity at the pipe wall and fluid viscosity must be within the limits shown to ensure that the fluid within the pocket is refreshed in a timely manner. This installation will not respond as rapidly as the free-stream installation to step changes in viscosity. - The thermal mass of the flanges may affect the response time of the meter ...

  • Emerson Micro Motion Fork Viscosity Meters - page 19

    2.4 Mount with a flow-through chamber Flow-through chambers are manufactured by Micro Motion, and are available with either weld-prepared ends or with flange or compression fittings for connection into the process pipelines. They are available with 1- inch NB, 2-inch NB, or 3-inch NB inlet and outlet pipes. Important The length of the inlet and out ...

  • Emerson Micro Motion Fork Viscosity Meters - page 20

    Flow-through chamber meter installation Figure 2-4: A A. Optional temperature port Note • This flow-through chamber is a direct-insertion type chamber that does not have a thermowell and uses a ¾ -inch Swagelok connection. • The three compression fittings on the flow pockets ( ½ -inch drain, ¾ -inch temperature probe, and 1- ½ - inch mounti ...

  • Emerson Micro Motion Fork Viscosity Meters - page 21

    Open-tank meter installation (long stem) Figure 2-5: 2. Confirm the meter tines are away from the tank wall. Meter placement (away from tank wall) Figure 2-6: B A A B A. 50 mm B. 200 mm 3. Confirm the meter tines are immersed in fluid. Mounting Installation Manual 17 ...

  • Emerson Micro Motion Fork Viscosity Meters - page 22

    Meter placement (immersed in fluid) Figure 2-7: 4. Confirm the meter tines are placed away from objects and disturbed flow. Meter placement (distance from objects and disturbed flow) Figure 2-8: A A A. 200 mm 5. If flow exists, confirm the meter tines are aligned so that the flow is directed towards or through the gap between the tines. Mounting 18 ...

  • Emerson Micro Motion Fork Viscosity Meters - page 23

    Meter placement (flow direction through tine gap) Figure 2-9: 6. Confirm the meter tines are kept away from deposit buildup. Meter placement (away from deposit buildup) Figure 2-10: 2.6 Mount in a closed tank (long-stem meter) 1. Attach the long-stem meter using the fitted flange attachment (shipped with the product). Mounting Installation Manual 1 ...

  • Emerson Micro Motion Fork Viscosity Meters - page 24

    Closed-tank installation (fitted flange attachment) Figure 2-11: 2. (Optional) To vary the insertion depth of the meter, mount the meter on a standoff section that attaches to the flange (not provided). Mounting 20 Micro Motion Fork Viscosity Meter ...

  • Emerson Micro Motion Fork Viscosity Meters - page 25

    Closed-tank installation (with standoff) Figure 2-12: A. Standoff height can vary (provided by customer) 3. Confirm the meter tines are away from the tank wall. Meter placement (away from tank wall) Figure 2-13: B A A B A. 50 mm B. 200 mm 4. Confirm the meter tines are immersed in fluid. Mounting Installation Manual 21 ...

  • Emerson Micro Motion Fork Viscosity Meters - page 26

    Meter placement (immersed in fluid) Figure 2-14: 5. Confirm the meter placement has allowed for the flexing of the tank lid to prevent the meter from being pushed towards a tank wall or into the path of disturbed flow. Meter placement (allowance for tank lid flexing) Figure 2-15: A A A. 200 mm 6. Confirm the meter tines are placed away from objects ...

  • Emerson Micro Motion Fork Viscosity Meters - page 27

    Meter placement (distance from objects and disturbed flow) Figure 2-16: A A A. 200 mm 7. If flow exists, confirm the meter tines are aligned so that the flow is directed towards or through the gap between the tines. Meter placement (flow direction through tine gap) Figure 2-17: 8. Confirm the meter tines are kept away from deposit buildup. Mounting ...

  • Emerson Micro Motion Fork Viscosity Meters - page 28

    Meter placement (away from deposit buildup) Figure 2-18: 2.7 Attach the PFA ring and circlip You attach the PFA ring (and circlip) around the boss on the underside of the meter flange to center the meter tines within a 2-inch Schedule 40 or 80 pipe. The circlip holds the ring in place. Note If you are using the Zirconium version of the meter, a sel ...

  • Emerson Micro Motion Fork Viscosity Meters - page 29

    Attaching a PFA ring and circlip Figure 2-19: B A C A. Circlip (not provided with self-locking PFA rings) B. PFA ring C. PFA ring and circlip attached 2.8 Rotate the electronics on the meter (optional) You can rotate the transmitter on the meter up to 90°. 1. Using a 4 mm hex key, loosen the cap screw that holds the transmitter in place. Component ...

  • Emerson Micro Motion Fork Viscosity Meters - page 30

    2.9 Rotate the display on the transmitter (optional) The display on the transmitter electronics module can be rotated 90° or 180° from the original position. Display components Figure 2-21: B C D A D E A. Transmitter housing B. Sub-bezel C. Display module D. Display screws E. Display cover Procedure 1. Power down the meter. 2. Turn the display co ...

  • Emerson Micro Motion Fork Viscosity Meters - page 31

    7. If you have removed the display screws, line them up with the matching holes on the sub-bezel, then reinsert and tighten them. 8. Place the display cover onto the main enclosure. 9. Turn the display cover clockwise until it is snug. 10. Power up the meter. Mounting Installation Manual 27 ...

  • Emerson Micro Motion Fork Viscosity Meters - page 32

    Mounting 28 Micro Motion Fork Viscosity Meter ...

  • Emerson Micro Motion Fork Viscosity Meters - page 33

    3 Wiring Topics covered in this chapter: • Available output terminals and wiring requirements • Explosion-proof/flameproof or non-hazardous output wiring • Processor wiring for remote-mount 2700 FOUNDATION fieldbus ™ option • Wiring to external devices (HART multidrop) • Wiring to signal converters and/or flow computers 3.1 Available ou ...

  • Emerson Micro Motion Fork Viscosity Meters - page 34

    3.2 Explosion-proof/flameproof or non-hazardous output wiring 3.2.1 Wire the Analog outputs version in an explosion-proof/ flameproof or non-hazardous area CAUTION! Meter installation and wiring should be performed by suitably trained personnel only in accordance with the applicable code of practice. Procedure Wire to the appropriate output termina ...

  • Emerson Micro Motion Fork Viscosity Meters - page 35

    Wiring the Analog outputs version Figure 3-1: mA1+ HART RS-485 PWR mA2 A A B RS-485 A RS-485 B C D B B A A A A. 24 VDC B. R load (250 Ω resistance) C. HART-compatible host or controller; and/or signal device D. Signal device Note For operating the milliamp outputs with a 24V supply, a maximum total loop resistance of 657 Ω is allowed. CAUTION! ? ...

  • Emerson Micro Motion Fork Viscosity Meters - page 36

    3.2.2 Wire the Discrete output version in an explosion-proof/ flameproof or non-hazardous area CAUTION! Meter installation and wiring should be performed by suitably trained personnel only in accordance with the applicable code of practice. Procedure Wire to the appropriate output terminal and pins (see Figure 3-2 ). Wiring 32 Micro Motion Fork Vis ...

  • Emerson Micro Motion Fork Viscosity Meters - page 37

    Wiring the Discrete output version Figure 3-2: mA1+ HART RS-485 PWR DO A A B RS-485 A RS-485 B C E D B A A A A. 24 VDC B. R load (250 Ω resistance) C. HART-compatible host or controller; and/or signal device D. R load (500 Ω resistance recommended) E. Discrete input device Note • For operating the milliamp output with a 24V supply, a maximum t ...

  • Emerson Micro Motion Fork Viscosity Meters - page 38

    • Metal cable glands should be used where the cables enter the meter amplifier box. Unused cable ports should be fitted with metal blanking plugs. 3.3 Processor wiring for remote-mount 2700 FOUNDATION fieldbus ™ option 3.3.1 RS-485 entity parameters for the remote-mount 2700 FOUNDATION fieldbus ™ option DANGER! Hazardous voltage can cause sev ...

  • Emerson Micro Motion Fork Viscosity Meters - page 39

    RS-485 output and cable entity parameters (continued) Table 3-2: Maximum external inductance (L o ) 260 µH Maximum external inductance/resistance ratio (L o /R o ) 124.4 µH/ Ω 3.3.2 Prepare the 4-wire cable Important For user-supplied cable glands, the gland must be capable of terminating the drain wires. Note If you are installing unshielded c ...

  • Emerson Micro Motion Fork Viscosity Meters - page 40

    4-wire cable preparation Figure 3-3: Cable layout Run conduit to sensor Metal conduit Wrap the drain wires twice around the shield and cut off the excess drain wires. Micro Motion cable gland Pass the wires through the gland. Terminate the drain wires inside the gland. Cable glands Remove the core processor cover Go to the shielding procedure Done ...

  • Emerson Micro Motion Fork Viscosity Meters - page 41

    4-wire cable shielding Figure 3-4: Assemble the Gland 1. Fold the shield or braid back over the clamping insert and 1/8 inch (3 mm) past the O-ring. 2. Install the gland body into the conduit opening on the core processor housing. 3. Insert the wires through gland body and tighten the gland nut onto the gland body. Apply the Heat Shrink 1. Slide th ...

  • Emerson Micro Motion Fork Viscosity Meters - page 42

    • Twisted pair construction. • Applicable hazardous area requirements, if the core processor is installed in a hazardous area. • Wire gauge appropriate for the cable length between the core processor and the transmitter. • Wire gauge of 22 AWG or larger, with a maximum cable length of 1000 feet. 3.3.3 Processor wiring for the remote-mount 2 ...

  • Emerson Micro Motion Fork Viscosity Meters - page 43

    3.4 Wiring to external devices (HART multidrop) You can wire up to three external HART devices with the meter. The following information provides wiring diagrams for making those connections in safe and hazardous environments. Wiring Installation Manual 39 ...

  • Emerson Micro Motion Fork Viscosity Meters - page 44

    3.4.1 Wire external HART devices in an explosion-proof/ flameproof or non-hazardous area Wiring external devices in an explosion-proof/flameproof or non-hazardous area Figure 3-6: 250 Ω 24 VDC mA1+ HART A B C E D A. HART Device 1 B. HART Device 2 C. HART Device 3 D. Meter (mA+/HART output) E. HART/Field Communicator CAUTION! • To meet the EC Dir ...

  • Emerson Micro Motion Fork Viscosity Meters - page 45

    3.5 Wiring to signal converters and/or flow computers For meters with a Time Period Signal (TPS) output, you can wire the meter to an signal converter or flow computer directly. The following information provides wiring diagrams for making those connections in safe and hazardous environments. When wiring the meter to an active HART host or signal c ...

  • Emerson Micro Motion Fork Viscosity Meters - page 46

    3.5.1 Wire to a signal converter/flow computer in an explosion-proof/flameproof or non-hazardous area Wiring to a signal converter/flow computer in an explosion-proof/ flameproof or non-hazardous area Figure 3-7: mA1+ HART RS-485 PWR TPS A A B 24 VDC RS-485 A RS-485 B A B A. Active HART host B. Active signal converter/flow computer CAUTION! • To ...

  • Emerson Micro Motion Fork Viscosity Meters - page 47

    4 Grounding The meter must be grounded according to the standards that are applicable at the site. The customer is responsible for knowing and complying with all applicable standards. Prerequisites Micro Motion suggests the following guides for grounding practices: • In Europe, EN 60079-14 is applicable to most installations, in particular Sectio ...

  • Emerson Micro Motion Fork Viscosity Meters - page 48

    Grounding 44 Micro Motion Fork Viscosity Meter ...

  • Emerson Micro Motion Fork Viscosity Meters - page 49

    Grounding Installation Manual 45 ...

  • Emerson Micro Motion Fork Viscosity Meters - page 50

    *MMI-20020994* MMI-20020994 Rev AA 2013 Micro Motion Inc. USA Worldwide Headquarters 7070 Winchester Circle Boulder, Colorado 80301 T +1 303-527-5200 T +1 800-522-6277 F +1 303-530-8459 www.micromotion.com Micro Motion Europe Emerson Process Management Neonstraat 1 6718 WX Ede The Netherlands T +31 (0) 318 495 555 F +31 (0) 318 495 556 www.micromot ...

メーカー Emerson カテゴリー TV Antenna

Emerson Micro Motion Fork Viscosity Metersのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Micro Motion Fork Viscosity Metersの取扱説明書
- Emersonの製品カード
- パンフレット
- またはEmerson Micro Motion Fork Viscosity Metersの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Emerson Micro Motion Fork Viscosity Metersの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Emerson Micro Motion Fork Viscosity Metersの取り付け説明書、サービスマニュアル、簡易説明書、またはEmerson Micro Motion Fork Viscosity Metersのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Emerson Micro Motion Fork Viscosity Metersの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Emerson Micro Motion Fork Viscosity Metersデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがEmerson Micro Motion Fork Viscosity Metersを使用するのを助ける技術的文書のことです。説明書は通常、全てのEmerson Micro Motion Fork Viscosity Metersユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Emersonの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Emerson Micro Motion Fork Viscosity Metersの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははEmerson Micro Motion Fork Viscosity Metersの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Emerson Micro Motion Fork Viscosity Metersに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Emerson Micro Motion Fork Viscosity Metersデバイスの基本機能を使うにあたってのヒント。 Emerson Micro Motion Fork Viscosity Metersのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Emerson Micro Motion Fork Viscosity Metersに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるEmerson Micro Motion Fork Viscosity Metersのメーカー/サービスへの連絡先に関する情報。

Emerson Micro Motion Fork Viscosity Metersについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもEmerson Micro Motion Fork Viscosity Metersの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがEmerson Micro Motion Fork Viscosity Metersで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)