Vulcan-Hart EF5 ML-114944の取扱説明書

16ページ 6.12 mb
ダウンロード

ページに移動 of 16

Summary
  • Vulcan-Hart EF5 ML-114944 - page 1

    – 1 – SER VICE MANUAL VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791 FORM 31208 (Apr. 2002) www.vulcanhart.com EF SERIES ST AND ARD AND FIL TER-READ Y GAS FR YERS MODELS EF 3 ML-52099 EF 4 ML-114943 EF 5 ML-114944 NOTICE THIS MANUAL IS PREPARED FOR THE USE OF TRAINED VULCAN SERVICE TECHNICIANS AND SHOULD NOT B ...

  • Vulcan-Hart EF5 ML-114944 - page 2

    – 2 – © VULCAN-HART COMPANY, 2002 T ABLE OF CONTENTS GENERAL .............................................................................................................................................................. 3 Introduction .............................................................................................................. ...

  • Vulcan-Hart EF5 ML-114944 - page 3

    – 3 – NOTE: If pilot does not remain lit, repeat steps 2 through 5, but allow a longer period of time before releasing the combination valve knob. Adjust pilot flame, if necessary, as outlined under Pilot Adjustment in Service Procedures and Adjustments. 6. Turn combination valve knob to ON. SPECIFICATIONS Gas Data TOOLS Standard • Hand tools ...

  • Vulcan-Hart EF5 ML-114944 - page 4

    – 4 – COVERS AND PANELS WARNING: SHUT OFF THE GAS BEFORE SERVICING. Door and Front Panel 1. Open door and remove screws from front panel. 2. Hold door. Lift up and remove front panel. 3. Lift door off bottom hinge. 4. Reverse procedure to install. Heat Shield 1. Remove screws holding heat shield in place. 2. Remove heat shield. BURNERS WARNING: ...

  • Vulcan-Hart EF5 ML-114944 - page 5

    – 5 – 3. Push burner up while pulling the bottom of the burner forward to clear the burner nozzle. 4. Reverse the procedure to install. THERMOSTAT WARNING: SHUT OFF THE GAS BEFORE SERVICING. 1. Drain shortening from fry tank. 2. Remove heat shield as outlined under Covers and Panels. 3. Remove left burner as outlined under Burners. 4. Remove th ...

  • Vulcan-Hart EF5 ML-114944 - page 6

    – 6 – 7. Loosen the packing nut and holding nut. 8. Remove the thermostat bulb from the clamp. 9. Pull the thermostat bulb through the underside of the fry tank and remove the thermostat assembly. 1 0. Reverse the procedure to install. When installing the new thermostat assembly, do not kink the thermostat capillary. Wrap threads of packing nut ...

  • Vulcan-Hart EF5 ML-114944 - page 7

    – 7 – 6. Loosen the packing nut and the holding nut. 7. Remove the high limit bulb from the clamp. 8. Pull the high limit bulb through the underside of the fry tank and remove the high limit assembly. 9. Reverse the procedure to install. When installing the new high limit assembly, do not kink the high limit capillary. Wrap threads of packing n ...

  • Vulcan-Hart EF5 ML-114944 - page 8

    – 8 – 6. Remove thermopile from pilot bracket. 7. Reverse procedure to install. PILOT ORIFICE WARNING: SHUT OFF THE GAS BEFORE SERVICING. WARNING: ALL GAS JOINTS DISTURBED DURING SERVICING MUST BE CHECKED FOR LEAKS. CHECK WITH SOAP AND WATER SOLUTION (BUBBLES). DO NOT USE AN OPEN FLAME. 1. Remove pilot assembly from fryer as outlined under ther ...

  • Vulcan-Hart EF5 ML-114944 - page 9

    – 9 – 5. Remove screws holding fry tank. 6. Remove burners as outlined under Burners. 7. Remove the manifold bracket from the tank assembly. 8. Remove thermostat and high limit as outlined under Thermostat and High Limit. 9. Remove screws holding pilot assembly to bracket and remove pilot assembly. 10. Lift the fry tank up and out of cabinet. C ...

  • Vulcan-Hart EF5 ML-114944 - page 10

    – 10 – SER VICE PR OCEDURES AND ADJUSTMENTS MILLIVOLT CONTROLS TEST 1. Verify proper gas (natural or propane) is present. 2 . Check for correct wiring and secure connections. 3. Verify the pilot flame is adjusted properly as outlined in Pilot Adjustment. 4. If the pilot is not lit, light pilot as outlined under Lighting Pilot. Allow the pilot t ...

  • Vulcan-Hart EF5 ML-114944 - page 11

    – 11 – 5. Allow temperature to stabilize at new setting and compare temperature tester to dial setting. Recalibrate if the temperature does not fall within the range of 330 ° F to 370 ° F. 6. If the temperature does not fall within the limits at both settings, replace the thermostat. PILOT ADJUSTMENT 1. Light pilot as outlined under Lighting ...

  • Vulcan-Hart EF5 ML-114944 - page 12

    – 12 – 2. Remove the plug from the submanifold and install pressure gauge at this point. 3. Turn on the gas and light the pilot as outlined under Lighting Pilot in General. 4. Turn the combination valve to ON. 5. Set the thermostat so the burners will come on. 6. Read the pressure gauge. The manifold pressure reading should match the pressure r ...

  • Vulcan-Hart EF5 ML-114944 - page 13

    – 13 – 3. Total Shutdown. A . When the high limit trips, 0.0 millivolts will read across both coils of the combination valve, causing both valves to close. B . Pilot relight cannot be accomplished until oil cools sufficiently to allow high limit to close. C . If any wire in the system is cut or broken, the system will shut down. SYSTEM CONDITIO ...

  • Vulcan-Hart EF5 ML-114944 - page 14

    – 14 – M V R E D W H T THERMOST A T LIMIT 2 3 4 1 PL-56159 SCHEMATIC COMPONENT FUNCTION Thermostat - Millivolt type with capillary bulb, single-throw break on temperature rise. Temperature range of 200 ° F to 400 ° F. Thermopile - Millivolt control with 24" capillary. Rated to generate 500 millivolts. Combination Valve - Regulates gas fl ...

  • Vulcan-Hart EF5 ML-114944 - page 15

    – 15 – TR OUBLESHOO TING SYMPTOM 1 . The temperature of the shortening drops, or excessive recovery time is required. POSSIBLE CAUSE A . Insufficient gas supply to unit. B . Ventilating system pulling heat out of heat exchanger and flue box. C . Overloading fryer capacity. A . Malfunctioning thermopile or loose/dirty connection in thermopile. B ...

  • Vulcan-Hart EF5 ML-114944 - page 16

    – 16 – FORM 31208 (Apr. 2002) PRINTED IN U.S.A. SYMPTOM 4. Leaking tank. TR OUBLESHOO TING POSSIBLE CAUSE A. Foam-over by depleted shortening permits oil to drip from the tank surface, giving the appearance of leaking. B . Careless draining procedures. Gas valve should be in the PILOT or OFF position before draining oil. Burners heating an empt ...

メーカー Vulcan-Hart カテゴリー Fryer

Vulcan-Hart EF5 ML-114944のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- EF5 ML-114944の取扱説明書
- Vulcan-Hartの製品カード
- パンフレット
- またはVulcan-Hart EF5 ML-114944の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Vulcan-Hart EF5 ML-114944の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Vulcan-Hart EF5 ML-114944の取り付け説明書、サービスマニュアル、簡易説明書、またはVulcan-Hart EF5 ML-114944のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Vulcan-Hart EF5 ML-114944の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Vulcan-Hart EF5 ML-114944デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがVulcan-Hart EF5 ML-114944を使用するのを助ける技術的文書のことです。説明書は通常、全てのVulcan-Hart EF5 ML-114944ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Vulcan-Hartの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Vulcan-Hart EF5 ML-114944の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははVulcan-Hart EF5 ML-114944の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Vulcan-Hart EF5 ML-114944に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Vulcan-Hart EF5 ML-114944デバイスの基本機能を使うにあたってのヒント。 Vulcan-Hart EF5 ML-114944のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Vulcan-Hart EF5 ML-114944に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるVulcan-Hart EF5 ML-114944のメーカー/サービスへの連絡先に関する情報。

Vulcan-Hart EF5 ML-114944についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもVulcan-Hart EF5 ML-114944の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがVulcan-Hart EF5 ML-114944で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)