    A product of VULCAN-HART LOUISVILLE, KY 40201-0696 F25111 (March 2002) - NOTICE - This Manual is prep ared for the use of trai ned Vulcan Servi c e Te ch nic ia ns and should not be us ed by those not properly qua li fied. If you have attended a Vulc an Service Sc hool for this product, yo u m ay be qualified to per form all the procedure s describ ...

  • Vulcan-Hart VPX5 126588 - page 2

    VPX SERIES STEAMERS F25111 (March 2002) Page 2 of 20 TABLE OF CONTENTS G E N E R A L ................................................................................ 3 Installation, O peration and Cleaning ........................................................ 3 Introduction ........................................................................ ...

  • Vulcan-Hart VPX5 126588 - page 3

    VPX SERIES STEAMERS - GENERAL F25111 (March 2002) Page 3 of 20 GENERAL INSTA LLA T I ON, OPERA TION A ND CLEANING Refer to the Inst allat ion & Operation Manual for specific instructions. NOTE: Daily cleaning is required. INTRODUCTIO N Features Requires no water or drain line connections (manual fill & manual drain) Cast aluminum "elem ...

  • Vulcan-Hart VPX5 126588 - page 4

    VPX SERIES STEAMERS - REMOVAL AND REPLACEM ENT OF PART S F25111 (March 2002) Page 4 of 20 REMOVAL AND REPLACEMENT OF PARTS COVERS A ND PA NELS WA RNING: DISCONNECT THE ELECTR ICAL POW ER TO TH E MACHINE AT THE MAIN CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT BOX INDICATI NG THE CIRCUIT IS BEING SERVICED. Right Side Panel 1. Remove screws from bottom of ...

  • Vulcan-Hart VPX5 126588 - page 5

    VPX SERIES STEAMERS - REMOVAL AND REPLACEM ENT OF PART S F25111 (March 2002) Page 5 of 20 4. Reverse procedure to install replacement component and check steamer for proper operation. NOTE: If replacing temperature cont rol, see "TEMPERATURE CONTRO L CALIBRATION - ADJUSTMENT FOR ELEVATION" in "SERVICE PROCEDURES AND ADJUSTMENTS" ...

  • Vulcan-Hart VPX5 126588 - page 6

    VPX SERIES STEAMERS - REMOVAL AND REPLACEM ENT OF PART S F25111 (March 2002) Page 6 of 20 NOTE: Thermostat base is a brass 5/8" hex with a threaded stem. 4. Apply a small amount of "thermal transfer compound" to the mating surface (disk side) of the replacement thermostat. A. Spread the compound completely and evenly over the surface ...

  • Vulcan-Hart VPX5 126588 - page 7

    VPX SERIES STEAMERS - REMOVAL AND REPLACEM ENT OF PART S F25111 (March 2002) Page 7 of 20 5. Remove mounting nuts & washers from the rear cooking compartment support legs and remov e base. 6. Disconnect heating element lead wires from element terminals. 7. Disconnect high limit thermostat lead wires and remove high lim it from heating element a ...

  • Vulcan-Hart VPX5 126588 - page 8

    VPX SERIES STEAMERS - REMOVAL AND REPLACEM ENT OF PART S F25111 (March 2002) Page 8 of 20 A. Temporarily install a flat washer and nut on all mounting studs. Hand tighten only . B. Tighten each nut to 100 in-lb using t he sequence as shown. C. Remove nut and washer from each mounting stud. D. Apply Loctit e 271 to heating element assembly mounting ...

  • Vulcan-Hart VPX5 126588 - page 9

    VPX SERIES STEAMERS - REMOVAL AND REPLACEM ENT OF PART S F25111 (March 2002) Page 9 of 20 5. Remove mounting nuts & washers from the rear cooking compartment support legs and remov e base. 6. Remove outer nut on drain valve stem and lift off drain handle assembly. 7. Remove manual drain v alve from cooking compartment drain pipe. 8. Clean threa ...

  • Vulcan-Hart VPX5 126588 - page 10

    VPX SERIES STEAMERS - REMOVAL AND REPLACEM ENT OF PART S F25111 (March 2002) Page 10 of 20 Gasket 1. Open the door. 2. Remove screws from the gask et plate. 3. Pull the gasket plate out from the door housing and remove the gasket. 4. Position the new gasket on t he gasket plat e and reverse the procedure to install. Adjust t he door as outlined und ...

  • Vulcan-Hart VPX5 126588 - page 11

    VPX SERIES STEAMER - SERVICE PROCEDURES AND ADJUSTM ENTS F25111 (March 2002) Page 11 of 20 Latch A ssembly 1. Open the door. 2. Remove screws from the top and bottom of the door. 3. Pull the "inner" door panel out from the door housing with the gasket plate and gasket st ill attached. 4. Remove the screws from the side edge of the door th ...

  • Vulcan-Hart VPX5 126588 - page 12

    VPX SERIES STEAMER - SERVICE PROCEDURES AND ADJUSTM ENTS F25111 (March 2002) Page 12 of 20 To adj u st : 1. Reinstall the st riker with t he slot pointing upwards and "hand tighten" nut only . 2. Close the door to cent er t he st rik er in the oval mounting hole. 3. Open the door and check the st rikers’ slot for horizontal alignment. T ...

  • Vulcan-Hart VPX5 126588 - page 13

    VPX SERIES STEAMER - SERVICE PROCEDURES AND ADJUSTM ENTS F25111 (March 2002) Page 13 of 20 VOLTAG E KW PER ELEMENT AMPS PER ELEMENT OHMS PER ELEMENT 1 PH 3 PH 208 3 14.4 8.3 14.4 240 3 12.5 7.2 19.2 480 3 3.6 76.8 208 5 24.0 14.0 8.70 240 5 21.0 12.0 11.5 480 5 6.0 46.0 NOTES: 1. Values in the table are nominal. Tolerance is +5/-10%. 2. Voltage val ...

  • Vulcan-Hart VPX5 126588 - page 14

    VPX SERIES STEAMER - ELECTRICAL OPERATION F25111 (March 2002) Page 14 of 20 ELECTRICAL OPERATION COMP ONENT FUNCTI ON B u z z e r .................. Signals end of a "cook" cycle when cooking time expires. C o n t a c t o r ............... Supplies line v oltage to heat ing elem ent assembly. R e l a y R 1 ................ Supplies power ...

  • Vulcan-Hart VPX5 126588 - page 15

    VPX SERIES STEAMER - ELECTRICAL OPERATION F25111 (March 2002) Page 15 of 20 SEQUENCE OF OPERA TION W iring diagram 7264 will be used to explain the electrical sequence of operation. Time d Cooking Mode 1. Conditions. A. Steamer connected to correct voltage and is properly grounded. B. Cooking mode switch (power) off. C. High limit thermostat closed ...

  • Vulcan-Hart VPX5 126588 - page 16

    VPX SERIES STEAMER - ELECTRICAL OPERATION F25111 (March 2002) Page 16 of 20 F. Door closed (door switch closed). G. Timer "off". H. Cooking compartment filled to the water level mark and below standby t em perature of 168 ° F (+5/-8). 2. Select "continuous" on the cooking mode switch. A. Internal "pilot" light (top, a ...

  • Vulcan-Hart VPX5 126588 - page 17

    VPX SERIES STEAMER - ELECTRICAL OPERATION F25111 (March 2002) Page 17 of 20 WIRING DI A GRAMS 208-240V ...

  • Vulcan-Hart VPX5 126588 - page 18

    VPX SERIES STEAMER - ELECTRICAL OPERATION F25111 (March 2002) Page 18 of 20 480V ...

  • Vulcan-Hart VPX5 126588 - page 19

    VPX SERIES STEAMER - TROUBLESHOOTING F25111 (March 2002) Page 19 of 20 TROUBLESHOOTING WA RNING: CERTAIN PROCEDURES IN THIS SECTION REQUIRE ELECT RICAL TESTS OR MEASUREMENTS W HILE POW ER IS APPLIED TO THE MACHINE. EXERCISE EXTREME CAUTION AT ALL TIMES. IF TEST POINTS ARE NOT EASILY ACCESSIBLE, DISCONNECT POW ER, ATTACH T EST EQUIPMENT AND REAPPLY ...

  • Vulcan-Hart VPX5 126588 - page 20

    VPX SERIES STEAMER - CONDENSED SPARE PARTS LIST F25111 (March 2002) Printed in U.S.A. CONDENSED SPARE PARTS LIST VPX3 & VPX5 PART NUMBER DESCRIPTION NOTES 844385 Door Gasket (VPX5) 844196 Door Gasket (VPX3) 843811 Door Switch 853928 Thermostat - Temperature Control 853956 Thermostat - Standby 853948 Thermocouple Sensor, J-Type 853957 Fuse Block ...

メーカー Vulcan-Hart カテゴリー Electric Steamer

Vulcan-Hart VPX5 126588のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- VPX5 126588の取扱説明書
- Vulcan-Hartの製品カード
- パンフレット
- またはVulcan-Hart VPX5 126588の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Vulcan-Hart VPX5 126588の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Vulcan-Hart VPX5 126588の取り付け説明書、サービスマニュアル、簡易説明書、またはVulcan-Hart VPX5 126588のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Vulcan-Hart VPX5 126588の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Vulcan-Hart VPX5 126588デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがVulcan-Hart VPX5 126588を使用するのを助ける技術的文書のことです。説明書は通常、全てのVulcan-Hart VPX5 126588ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Vulcan-Hartの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Vulcan-Hart VPX5 126588の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははVulcan-Hart VPX5 126588の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Vulcan-Hart VPX5 126588に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Vulcan-Hart VPX5 126588デバイスの基本機能を使うにあたってのヒント。 Vulcan-Hart VPX5 126588のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Vulcan-Hart VPX5 126588に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるVulcan-Hart VPX5 126588のメーカー/サービスへの連絡先に関する情報。

Vulcan-Hart VPX5 126588についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもVulcan-Hart VPX5 126588の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがVulcan-Hart VPX5 126588で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)