    GS-XP07FR GS-XP09FR GS-XP12FR GS-XP18FR GS-XP24FR GS-XP27FR GS-XP07FR GS-XP09FR GS-XP12FR GS-XP18FR GS-XP24FR GS-XP27FR AE-X7FR AE-X9FR AE-X12FR GU-XR18FR GU-XR24FR GU-XR27FR FLOOR/CEILING TYPE ROOM AIR CONDITIONER OPERA TION MANUAL TIPO DE SUELO/TECHO ACONDICIONADOR DE AIRE P ARA HABIT ACIÓN MANUAL DE INSTRUCCIONES TIPO DI P A VIMENTO/SOFFITT O C ...

  • Sharp GS-XP09FR - page 2

    GS-XP07FR_Eng.p65 05.4.19, 5:05 PM 2 A. Information on Disposal for Users (p ri v ate households) 1. In the European Un ion Attention: If you w ant to dispose of this equip ment, please do not use the ordinar y dust bin! Used electrical a nd electronic equip m en t must be treated sep arately and in accordance w i th legislation that requires prope ...

  • Sharp GS-XP09FR - page 3

    ENGLISH E-1 ENGLISH Thank you for purchasing a SHARP air conditioner. Please read this manual carefully before operating the product. • IMPORTANT SAFETY INSTRUCTIONS ..... E-1 • ADDITIONAL NOTES ON OPERATION ............. E-3 • TIPS ON SAVING ENERGY ........................ E-3 • PART NAMES .............................................. E-4 ...

  • Sharp GS-XP09FR - page 4

    IMPORT ANT SAFETY INSTRUCTIONS CAUTIONS FOR USE 1 Open a window or door periodically to ventilate the room, especially when using gas appliances. Insufficient ventilation may cause oxygen shortage. 2 Do not operate the buttons with wet hand. It may cause electric shock. 3 For safety, turn the circuit breaker off when not using the unit for an exten ...

  • Sharp GS-XP09FR - page 5

    ENGLISH INDOOR TEMP. OUTDOOR TEMP. COOLING upper limit 32 ˚ C D.B. 43 ˚ C D.B. 23 ˚ C W.B. - lower limit 21 ˚ C D.B. 21 ˚ C D.B. 15 ˚ C W.B. - HEATING upper limit 27 ˚ C D.B. 24 ˚ C D.B. - 18 ˚ C W.B. lower limit 20 ˚ C D.B. -7 ˚ C D.B. - -8 ˚ C W.B. ADDITIONAL NOTES ON OPERA TION OPERATING TEMPERATURE RANGE • The built-in protective ...

  • Sharp GS-XP09FR - page 6

    P ART NAMES 1 Outlet (Air) 2 Vertical Adjustment Louvres 3 Horizontal Adjustment Louvres 4 Indicator Panel 5 Air Filters 6 Intake Grille 7 Inlet (Air) 8 Remote Control 9 OPERATION Lamp (red ) 0 TIMER Lamp (orange ) q PLASMACLUSTER Lamp (blue) w RECEIVER Window e AUX. Button r Inlet (Air) t Interconnecting Cord and Refrigerant Tube y Drainage Hose u ...

  • Sharp GS-XP09FR - page 7

    ENGLISH REMOTE CONTROL 1 TRANSMITTER 2 DISPLAY (Liquid Crystal Display) 3 PLASMACLUSTER Button 4 ON/OFF Button 5 THERMOSTAT Button 6 FULL POWER Button 7 MODE Button 8 ONE-HOUR OFF TIMER Button 9 TIMER ON Button (for setting the timer) 0 TIMER OFF Button (for setting the timer) q TIME ADVANCE Button w TIME REVERSE Button e FAN Button r TIMER SET/CAN ...

  • Sharp GS-XP09FR - page 8

    1 Remove the remote control cover. 2 Insert batteries in the compart- ment, making sure the ± and — polarities are correctly aligned. • The display indicates "AM 6:00" when batteries are prop- erly installed. 3 Reinstall the cover. USING THE REMOTE CONTROL E-6 NOTES: • The battery life is approximately one year in normal use. • W ...

  • Sharp GS-XP09FR - page 9

    ENGLISH E-7 CAUTION • Do not allow the signal receiver window to receive strong direct sunlight, since it can adversely affect its operation. If the signal receiver window is exposed to direct sunlight, close a curtain to block the light. • Using a fluorescent lamp with a quick starter in the same room may interfere with transmission of the sig ...

  • Sharp GS-XP09FR - page 10

    SWING FAN MODE SET/C 1h Press the THERMOSTAT button to set the desired temperature. • In the AUTO and DRY modes, the tem- perature can be changed in 1°C incre- ments within the range of 2°C higher to 2°C lower from the temperature auto- matically determined by the air conditioner. • In the COOL and HEAT modes, the tempera- ture can be set wi ...

  • Sharp GS-XP09FR - page 11

    ENGLISH E-9 During operation, if the outdoor temperature changes, the temperature settings will automatically slide as shown in the chart. MODE CHANGEOVER During seasons when you need COOLING at daytime and HEATING at night, or if the room temperature should become extremely higher than the temperature setting, due to supplementary heating equipmen ...

  • Sharp GS-XP09FR - page 12

    E-10 ADJUSTING THE AIR FLOW DIRECTION VERTICAL AIR FLOW DIRECTION HOW TO ADJUST THE AIR FLOW DIRECTION HEAT mode COOL and DRY modes The adjustment range is narrower the SWING range in order to prevent con- densation from dripping. The range is wide so the air flow can be directed toward the floor. Hold the horizontal adjustment louvre as shown in t ...

  • Sharp GS-XP09FR - page 13

    ENGLISH E-1 1 FULL POWER OPERA TION In this operation, the air conditioner works at maximum power to makes the room cool or warm so rapidly that you can use it just after you come home. 1 Press the ONE-HOUR OFF TIMER button. • The remote control displays “ ”. • The orange TIMER lamp ( ) on the unit will light up. • The unit will stop oper ...

  • Sharp GS-XP09FR - page 14

    1 Press the TIMER OFF ( ) button. 2 The TIMER OFF indicator will blink; press the TIME ADVANCE or REVERSE buttons to set the desired time. (The time can be set in 10- minute increments.) 3 Point the remote control at the signal receiver window on the unit and press the TIMER SET (SET/C) button. • The orange TIMER lamp ( ) on the unit will light. ...

  • Sharp GS-XP09FR - page 15

    ENGLISH 1 Press the TIMER ON ( ) button. 2 The TIMER ON indicator will blink; press the TIME ADVANCE or REVERSE buttons to set the de- sired time. (The time can be set in 10-minute increments.) 3 Point the remote control at the signal receiver window on the unit and press the TIMER SET (SET/C) button. • The orange TIMER lamp ( ) on the unit will ...

  • Sharp GS-XP09FR - page 16

    E-14 1 TIPS ABOUT PLASMACLUSTER OPERA TION The Plasmacluster ion generator inside the air conditioner will release positive and negative Plasmacluster ions into the room. Approximately the same numbers of positive and negative ions released into the air will reduce some airborne mold. PLASMACLUSTER OPERA TION 1 During operation, press the PLASMACLU ...

  • Sharp GS-XP09FR - page 17

    ENGLISH MAINTENANCE Be sure to disconnect the power cord from the wall outlet or turn off the circuit breaker before performing any maintenance. MAINTENANCE AFTER AIR CONDITIONER SEASON 1 Operate the unit in the COOL mode, temperature setting 32°C, for about half a day to allow the mechanism to thoroughly dry. 2 Stop the operation and unplug the u ...

  • Sharp GS-XP09FR - page 18

    CLEANING THE FIL TERS E-16 MAINTENANCE The air filters should be cleaned every two weeks. 1 TURN OFF THE UNIT 2 OPEN THE INTAKE GRILLE 1 Slide the stoppers to the left ( OPEN ). Two stoppers are provided for each the intake grille. 2 Gently pull and open the intake grille. 3 REMOVE THE AIR FILTERS Push both projections on the air fil- ters slightly ...

  • Sharp GS-XP09FR - page 19

    ENGLISH IF THE UNIT FAILS TO RECEIVE THE REMOTE CONTROL SIGNAL Check whether the remote con- trol batteries have become old and weak. Try to send the signal again with the remote control pointed prop- erly towards the unit’s signal re- ceiver window. Check whether the remote con- trol batteries are installed with the polarities properly aligned. ...

  • Sharp GS-XP09FR - page 20

    SHARP CORPORA TION OSAKA, JAPAN TINSEA417JBRZ TH 05D- 1 Printed in Thailand GS-XP07FR_Eng.p65 05.4.1, 4:42 PM 20 ...

メーカー Sharp カテゴリー Air Conditioner

Sharp GS-XP09FRのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- GS-XP09FRの取扱説明書
- Sharpの製品カード
- パンフレット
- またはSharp GS-XP09FRの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Sharp GS-XP09FRの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Sharp GS-XP09FRの取り付け説明書、サービスマニュアル、簡易説明書、またはSharp GS-XP09FRのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Sharp GS-XP09FRの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Sharp GS-XP09FRデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがSharp GS-XP09FRを使用するのを助ける技術的文書のことです。説明書は通常、全てのSharp GS-XP09FRユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Sharpの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Sharp GS-XP09FRの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははSharp GS-XP09FRの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Sharp GS-XP09FRに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Sharp GS-XP09FRデバイスの基本機能を使うにあたってのヒント。 Sharp GS-XP09FRのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Sharp GS-XP09FRに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるSharp GS-XP09FRのメーカー/サービスへの連絡先に関する情報。

Sharp GS-XP09FRについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもSharp GS-XP09FRの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがSharp GS-XP09FRで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)