    1 Model 5000 Electronic Air Cleaner Installation Instructions WARNING 120 Volts may cause serious injury from electrical shock. Disconnect power to the furnace/air handler before starting installation. Leave power disconnected until installation is completed. Arcing in electrical components may cause an explosion. Do not install unit where explosiv ...

  • Aprilaire 5000 - page 2

    2 31" with Door 28-1/8" without Door 12" 24-5/8" 23-7/8" 15-1/2" 17-3/4" 18-3/8" 15-1/2" FIGURE 1 – Dimensions of the Model 5000 Electronic Air Cleaner 90-1346 SPECIFICA TIONS TABLE 2 – Model 5000 Initial Airflow Resistance (inches w.c.) Airflow (CFM) 1000 1200 1400 1600 1800 2000 .10 .14 .17 .21 .25 ...

  • Aprilaire 5000 - page 3

    3 Pleat Spacers (6) #501 Media Outer Housing with Door Retainers Inner Housing Assembly Inner Housing Ionizer Frame Control Electrode Power Pack/Door Assembly On/Off Switch Latches 90-1152 FIGURE 2 – Model 5000 Electronic Air Cleaner COMPONENTS ...

  • Aprilaire 5000 - page 4

    4 LOCATING THE AIR CLEANER Airflow Airflow Airflow Airflow 30 max. 45 max. Minimize Angles Where Possible Airflow Plenum Box Airflow Plenum Box Size Plenum Box to fit outer housing without door: 17-3/4” x 28-1/8” . See Figure 1 for complete dimensions. FIGURE 8 FIGURE 9 FIGURE 6 FIGURE 7 FIGURE 4 FIGURE 5 Note: Air Cleaner outer housing can sup ...

  • Aprilaire 5000 - page 5

    5 1. Turn the system OFF at the thermostat by changing the mode selector to OFF – this may be a switch or a pushbutton, depending on the type of thermostat. 2. Disconnect power service to the furnace or air handler. 3. Remove air cleaner power pack / door assembly and pull inner assembly out of the outer housing. 4. Remove the media carton and th ...

  • Aprilaire 5000 - page 6

    6 WIRING AND START UP 1. Install a grounded (earth ground) 120-volt single receptacle outlet in accordance with NEC Standards and local codes, into which the EAC will be plugged. This outlet is to be live only when the furnace/air handler blower is running. For equipment with EAC terminals: A. Install a single-receptacle outlet to the furnace/air h ...

  • Aprilaire 5000 - page 7

    7 EA C NEUTRAL GND HV AC Equipment Control Center Circuit Board IT IS COMMON TO SEE SP ADE TERMINALS ON THE HV AC EQUIPMENT CONT RO L CENTER CIRCUIT BOARD . USE ONL Y FULL Y INSULA TED FITTINGS (FEMALE QUICK DISCONNECTS SHO WN ). 3-PRONG OUTLET WIRED TO HV AC SYSTEM EA C TERMINAL HV AC EQUIPMENT CONTROL CENTER GND GRN WHT BLK HV AC EQUIPMENT LINE 3 ...

  • Aprilaire 5000 - page 8

    8 TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE(S) SOLUTION(S) Light does not come on at all after 90 seconds ON/OFF switch not in ON position Turn switch ON. Air cleaner not plugged in Plug in air cleaner. Insufficient current to activate Model 51 relay Wrap blower common wire around relay bracket more – see Figure 14 on page 7 for wire wrapping ...

  • Aprilaire 5000 - page 9

    9 MAINTENANCE RECOMMENDATIONS Whenever performing maintenance on the air cleaner, turn off the HVAC system, then turn off and unplug the air cleaner. Before performing any maintenance item listed below: 1. At the thermostat, turn the Fan to Auto (this is done with a switch or a button on the thermostat – refer to thermostat Operating Instructions ...

  • Aprilaire 5000 - page 10

    10 Inner Housing Ionizer Fram e Control Electrode Control Electrode Ionizer Frame Control Electrode Ground Contact Media Ground Contacts Ionizer Wires Bus Bar FIGURE 16 – Maintenance 90-1151 ...

  • Aprilaire 5000 - page 11

    11 APPLICATIONS WITH A HUMIDIFIER An Aprilaire ® Automatic Humidifier can be mounted upstream from the air cleaner. CAUTION Do not install an atomizing humidifier upstream from the air cleaner. ...

  • Aprilaire 5000 - page 12

    P.O. Box 1467 • Madison, WI 53701-1467 • Phone: 800/334-6011 • Fax: 608/257-4357 • www.aprilairepartners.com 10007971 2.14 B2701048B Printed in U.S.A. © 2014 Aprilaire – A division of Research Products Corporation ...

メーカー Aprilaire カテゴリー Air Cleaner

Aprilaire 5000のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 5000の取扱説明書
- Aprilaireの製品カード
- パンフレット
- またはAprilaire 5000の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Aprilaire 5000の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Aprilaire 5000の取り付け説明書、サービスマニュアル、簡易説明書、またはAprilaire 5000のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Aprilaire 5000の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Aprilaire 5000デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAprilaire 5000を使用するのを助ける技術的文書のことです。説明書は通常、全てのAprilaire 5000ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Aprilaireの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Aprilaire 5000の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAprilaire 5000の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Aprilaire 5000に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Aprilaire 5000デバイスの基本機能を使うにあたってのヒント。 Aprilaire 5000のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Aprilaire 5000に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAprilaire 5000のメーカー/サービスへの連絡先に関する情報。

Aprilaire 5000についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAprilaire 5000の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAprilaire 5000で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)