Chauvet Q-ScanTM 250の取扱説明書

17ページ 0.49 mb
ダウンロード

ページに移動 of 17

Summary
  • Chauvet Q-ScanTM 250 - page 1

    CHAUVET, 30 00 N 29 th Ct, Hollywoo d, FL 3302 0 U.S.A (800) 762-1084 – (954) 929-111 5 FAX (954) 929-5 560 www.chauvetlig hting.com 2005-11 -15/13:24 Q-Scan ™ 250 250W HSD Intelligen t Scanner Q-Roll ™ 250 250W HSD Intell igent Barrel Sca nner USER MANUAL ...

  • Chauvet Q-ScanTM 250 - page 2

    Q-Scan 250 & Q- Roll 250 User Manual 2 2005-11 -15/13:24 T able of Con tent BEFOR E Y OU B EGIN....................................................................................................................................................... 3 W HAT IS INCLUDED ........ ........ ....... ........ ....... ........ ........ ....... ........ . ...

  • Chauvet Q-ScanTM 250 - page 3

    Q-Scan 250 & Q- Roll 250 User Manual 3 2005-11 -15/13:24 Figure 1 - AC Voltage Switch B EFORE Y OU B EGIN What is included  Q-Scan ™ 250 w ith MSD250 bulb or Q-Roll ™ 250 w ith MSD250bulb  Removable feet  Power cord w ith plug  Manual  Warranty Card Unpacking Instructi ons Immediately upon re ceiving a fix ture, carefully unp ...

  • Chauvet Q-ScanTM 250 - page 4

    Q-Scan 250 & Q- Roll 250 User Manual 4 2005-11 -15/13:24 I NTRODUCTION Technical Features Q-Scan ™ 250 Q-Roll ™ 250 Control Feature s  6-7 channel DMX Intelligent Scann er  Pan: 180°  Tilt: 70°  Mechanical Dimme r/Shutter/St robe  Rotating Gobos - 8 interchangeabl e rotating g obos - 6 metal, 2 glass, 2 Free gobos - Gobo Bo ...

  • Chauvet Q-ScanTM 250 - page 5

    Introduction Q-Scan 250 & Q- Roll 250 User Manual 5 2005-11 -15/13:24 Product Over view Control Board Enter Choose Up Down     SEGMENT BUTT ONS I/O PANE L OVERV IEW B UTTONS I/O P AN EL Choose Toggles menu f unctions DMX Out & In DMX-512 co nnectors Down Steps backward t hrough menu functions Power AC input IEC 60320 C14 and fus ...

  • Chauvet Q-ScanTM 250 - page 6

    Q-Scan 250 & Q- Roll 250 User Manual 6 2005-11 -15/13:24 S1 S2 S1 S ETUP Lamp You will need to in stall a lamp prio r to the initial oper ation of the fixture. An M SD250 high intens ity discharge la mp is included. Warning! When replacing the lamp, please wait 15 minutes after powering down to allow the unit to cool down! Always disconnect fro ...

  • Chauvet Q-ScanTM 250 - page 7

    Introduction Q-Scan 250 & Q- Roll 250 User Manual 7 2005-11 -15/13:24 Slide switch up or down depending on your line voltag e. Lamp Alignment S crews are accessible via the rear plate. S2 Lamp Alignment How-To Often, after a new installation of a lamp, you will find that there is an uneven field of light or w hat is referred to as a hot spot . ...

  • Chauvet Q-ScanTM 250 - page 8

    Introduction Q-Scan 250 & Q- Roll 250 User Manual 8 2005-11 -15/13:24 Mounting O r i e n t a t i o n Both fixtures can sit on stage or be mounted on a truss u sing a clamp in any position , provided, there is adequate roo m for ventilation. W a r n i n g It is important never to obstruct the fan or vent s pathw ay.  When selecting ins tallat ...

  • Chauvet Q-ScanTM 250 - page 9

    Q-Scan 250 & Q- Roll 250 User Manual 9 2005-11 -15/13:24 O PERA TING I NSTRUCTIO NS Control Panel On the control pan el you can set the DMX address, set the fix ture to Master/ Slave mode, rese t the fixture and change fixture personality traits. Control Panel Func tions F UNCTION O PTION S N OTES   /  Pan invert  ...

  • Chauvet Q-ScanTM 250 - page 10

    Q-Scan 250 & Q- Roll 250 User Manual 10 2005-11 -15/13:24 Note! If the fixture is con nected to a controller, please disconnect it. The display will r ead the previou sly selected setting. Only one fixture ca n be the Maste r assigned fixture. H owever, 1 6 units can be slaved to t he master unit. Operating Modes  A stand-alone mode will lis ...

  • Chauvet Q-ScanTM 250 - page 11

    Operating Instruc tions Q-Scan 250 & Q- Roll 250 User Manual 11 2005-11 -15/13:24 Daisy Chain Connection D M X M o d e Operating in a DM X Control mode environ ment gives the user the grea test flexibility w hen it comes to customizing or creat ing a show . You can tailor y our progra mming to suit a specific event . Whether it is a weddin g wh ...

  • Chauvet Q-ScanTM 250 - page 12

    Q-Scan 250 & Q- Roll 250 User Manual 12 2005-11 -15/13:24 User Configurat ions P 1 - P a n I n v e r t / P 2 - T i l t I n v e r t It is possible to inv ert the pan and tilt mirror mov ement fro m within the fix ture itself. This could be helpful in situation s where the po sitioning or rigging of a fixtur e led to a rev erse orientation of the ...

  • Chauvet Q-ScanTM 250 - page 13

    Q-Scan 250 & Q- Roll 250 User Manual 13 2005-11 -15/13:24 A PPENDIX DMX Primer There are 512 channe ls in a DMX -512 connec tion. Channels may be assigne d in any manner. A fixture capable of receiving DMX -512 w ill require one or a nu mber of sequential channels. The u ser must assign a start ing address on the fixtur e that indicate s the fi ...

  • Chauvet Q-ScanTM 250 - page 14

    Appendix Q-Scan 250 & Q- Roll 250 User Manual 14 2005-11 -15/13:24 DMX Channel Value s (16 Bit) D EFAULT V ALUE F UNCTION 1 000  255 Pan Left > Right ( 128 = center) 000  255 Tilt (Q-Sc an 250) Up > Down (128 = center) 2 000  005 006  120 121  140 141  255 Barrel Spin (Q-Ro ll 250) Stop Rotation: Fast > S low (clock w ...

  • Chauvet Q-ScanTM 250 - page 15

    Q-Scan 250 & Q- Roll 250 User Manual 15 2005-11 -15/13:24 Maintenance To maintain opti mum performan ce and minimize wear fix tures should be clea ned frequently. Usage and environment ar e contributing factors in deter mining frequency. As a gener al rule, fixture s should be cleaned at lea st twice a mon th. Dust build up reduces ligh t outpu ...

  • Chauvet Q-ScanTM 250 - page 16

    Appendix Q-Scan 250 & Q- Roll 250 User Manual 16 2005-11 -15/13:24 General Troublesho oting Applies to Symptom Solution(s) Lights Foggers & Snow Contr ollers Dimmers & Chaser Auto shut off Check fan ther mal switch reset  Beam is very dim or not bright Clean optical syste m or replace lamp Check 220/110v switch for prop er setting ? ...

  • Chauvet Q-ScanTM 250 - page 17

    Appendix Q-Scan 250 & Q- Roll 250 User Manual 17 2005-11 -15/13:24 Technical Specific ations WEIGHT & DIMEN SIONS Leng th ........................................................................................................................ 292 mm ( 11.5 i n) Width .......................................................................... ...

メーカー Chauvet カテゴリー Scanner

Chauvet Q-ScanTM 250のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Q-ScanTM 250の取扱説明書
- Chauvetの製品カード
- パンフレット
- またはChauvet Q-ScanTM 250の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Chauvet Q-ScanTM 250の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Chauvet Q-ScanTM 250の取り付け説明書、サービスマニュアル、簡易説明書、またはChauvet Q-ScanTM 250のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Chauvet Q-ScanTM 250の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Chauvet Q-ScanTM 250デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがChauvet Q-ScanTM 250を使用するのを助ける技術的文書のことです。説明書は通常、全てのChauvet Q-ScanTM 250ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Chauvetの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Chauvet Q-ScanTM 250の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははChauvet Q-ScanTM 250の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Chauvet Q-ScanTM 250に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Chauvet Q-ScanTM 250デバイスの基本機能を使うにあたってのヒント。 Chauvet Q-ScanTM 250のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Chauvet Q-ScanTM 250に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるChauvet Q-ScanTM 250のメーカー/サービスへの連絡先に関する情報。

Chauvet Q-ScanTM 250についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもChauvet Q-ScanTM 250の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがChauvet Q-ScanTM 250で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)