    Page 1 R-3451 INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL CAST IRON UNVENTED ROOM HEA TER MODEL CIVF-25-2 EFFECTIVE DA TE JUL Y , 2000 This is an unvented gas-fir ed heater . It uses air (oxygen) fr om the r oom in which it is installed. Pr ovisions for adequate com- bustion and ventilation air must be pr o- vided. Refer to page 4. W ARNING ...

  • Empire Comfort Systems CIVF-25-2 - page 2

    Page 2 R-3451 Introduction Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of an unvented room heater. This appliance may be installed in an aftermarket* permanently located, manufactured (mobile) home, where not prohibited by state or local codes. *Aftermarket: Completion of ...

  • Empire Comfort Systems CIVF-25-2 - page 3

    Page 3 R-3451 Some people cannot smell well. Some people cannot smell the odor of the chemical stench put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor. Some- times other odors in the area ...

  • Empire Comfort Systems CIVF-25-2 - page 4

    Page 4 R-3451 Provisions for Adequate Combustion and Ventilation Air This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. The National Fuel Gas Code, ANSI Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet pe ...

  • Empire Comfort Systems CIVF-25-2 - page 5

    Page 5 R-3451 Figure 1 Figure 2 Figure 3 ...

  • Empire Comfort Systems CIVF-25-2 - page 6

    Page 6 R-3451 Appliance Hardware Package (Figure 4) Figure 4 Appliance Hardware Package Parts List Part Part Quantity Description Number Supplied 1/4-20 x 1" Phillips Head Bolt R-3188 4 1/4-20 x 3/8" Phillips Head Bolt R-3646 16 1/4-20 x 1/2" Leveling Bolt R-3747 4 No. 10 x 1/2" R-2737 6 Hex Washer Head Screw 1/4-20 Washer Head ...

  • Empire Comfort Systems CIVF-25-2 - page 7

    Page 7 R-3451 Figure 6 10. Attach the (4) 1-1/4" x 1/2" retaining tabs to the casing front with (4) 3/8" bolts. The retaining tabs should be positioned downward, from the casing front, top to the casing front, bottom. 11. Refer to Figure 8, attach casing front to outer casing by using the (4) retaining tabs on the casing front. The ( ...

  • Empire Comfort Systems CIVF-25-2 - page 8

    Page 8 R-3451 Figure 8 Figure 9 Stone Inlay Replacement of Standard Grille Top Whenever the standard grille top is replaced with a stone inlay you must install the top shield and heat shield, which are provided with the stone inlay. Installation of Optional Stone Inlay 1. Remove left grille, center grille and right grille from casing top. 2. Remove ...

  • Empire Comfort Systems CIVF-25-2 - page 9

    Page 9 R-3451 3. Place the casing top on a non-abrasive surface in order to protect the porcelain finish. The exterior of the casing top should be facing the non-abrasive surface. 4. Attach 11 5/8" x 11 5/8" top shield to the interior of the casing top with (1) 3/8" bolt provided in hardware package. 5. Locate the (4) screw holes on ...

  • Empire Comfort Systems CIVF-25-2 - page 10

    Page 10 R-3451 2. The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). 3. The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing o ...

  • Empire Comfort Systems CIVF-25-2 - page 11

    Page 11 R-3451 Main Burner Flame Pattern (Figure 15 and Figure 16) Figure 15 shows a correct main burner flame pattern. Figure 16 shows an incorrect main burner flame pattern. Correct Main Burner Flame Figure 15 Incorrect Main Burner Flame Figure 16 If main burner flame pattern is incorrect, as shown in Figure 16 • See Troubleshooting, page 15. C ...

  • Empire Comfort Systems CIVF-25-2 - page 12

    Page 12 R-3451 Wiring of ON/OFF/REMOTE Switch with 750 Millivolt Wall Thermostat Accessory and Another Accessory Connect the green and red, stripped and bare, wires on the ON/OFF/ REMOTE switch wire harness to the 750 millivolt wall thermostat AND to the remote receiver that is a component in the FRBC-1, FREC-1 OR to the FWS-1, wall switch. 1. Conn ...

  • Empire Comfort Systems CIVF-25-2 - page 13

    Page 13 R-3451 Figure 19 Operating Guidelines Before operating this heater, please review the safety warnings pages at the beginning of this manual and those precautions and warnings listed below. 1. Know what type of ignition system this model has (standing pilot) and follow the applicable SAFETY and LIGHTING instructions. 2. Check to ensure there ...

  • Empire Comfort Systems CIVF-25-2 - page 14

    Page 14 R-3451 FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all a ...

  • Empire Comfort Systems CIVF-25-2 - page 15

    Page 15 R-3451 TROUBLE-SHOOTING SYMPTOMS - POSSIBLE CAUSES AND CORRECTIONS IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. 1. When ignitor butt ...

  • Empire Comfort Systems CIVF-25-2 - page 16

    Page 16 R-3451 Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62222-0529 How To Order Repair Parts ... Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer . ...

  • Empire Comfort Systems CIVF-25-2 - page 17

    Page 17 R-3451 Index Part No. Number Description Index Part No. Number Description PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. Parts List for CIVF-25 Firebox 1 *CI-006 WINDOW RETAINING TAB 2 R-3948 WINDOW (BLACK PAINT) 2 R-3688 WINDOW (BLACK ENAMEL) 2 R-3696 WINDOW (SAND ENAMEL) 2 R-3704 ...

  • Empire Comfort Systems CIVF-25-2 - page 18

    Page 18 R-3451 ...

  • Empire Comfort Systems CIVF-25-2 - page 19

    Page 19 R-3451 OPTIONAL BLOWER CIB-2 Unvented Room Heater CIVF-25 Installing Optional CIB-2 Blower 1. Loosen, but do not remove, (4) hex-head screws located on the exterior, bottom of the appliance. 2. Position the blower assembly at the rear of the appliance. The blower assembly has (4) keyholes for attachment to the exterior, bottom of the applia ...

  • Empire Comfort Systems CIVF-25-2 - page 20

    Page 20 R-3451 Cleaning The blower wheel will collect lint and could require cleaning once a year. If the air output decreases or the noise level increases, it indicates a dirty wheel. Blower Motor The blower motor does not have oiling holes. Do not attempt to oil blower motor. PARTS LIST Index Part No. No. Description 1 R-1454 Brass Bushing (4 Req ...

メーカー Empire Comfort Systems カテゴリー Electric Heater

Empire Comfort Systems CIVF-25-2のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CIVF-25-2の取扱説明書
- Empire Comfort Systemsの製品カード
- パンフレット
- またはEmpire Comfort Systems CIVF-25-2の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Empire Comfort Systems CIVF-25-2の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Empire Comfort Systems CIVF-25-2の取り付け説明書、サービスマニュアル、簡易説明書、またはEmpire Comfort Systems CIVF-25-2のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Empire Comfort Systems CIVF-25-2の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Empire Comfort Systems CIVF-25-2デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがEmpire Comfort Systems CIVF-25-2を使用するのを助ける技術的文書のことです。説明書は通常、全てのEmpire Comfort Systems CIVF-25-2ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Empire Comfort Systemsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Empire Comfort Systems CIVF-25-2の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははEmpire Comfort Systems CIVF-25-2の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Empire Comfort Systems CIVF-25-2に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Empire Comfort Systems CIVF-25-2デバイスの基本機能を使うにあたってのヒント。 Empire Comfort Systems CIVF-25-2のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Empire Comfort Systems CIVF-25-2に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるEmpire Comfort Systems CIVF-25-2のメーカー/サービスへの連絡先に関する情報。

Empire Comfort Systems CIVF-25-2についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもEmpire Comfort Systems CIVF-25-2の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがEmpire Comfort Systems CIVF-25-2で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)