Haier HBU-18CF03の取扱説明書

24ページ 0.61 mb
ダウンロード

ページに移動 of 24

Summary
  • Haier HBU-18CF03 - page 1

    HBU-18CF03 HBU-18HF03 Operation & Installation Manual CASSETTE TYPE AIR CONDITIONER Indoor Unit No. 0010576826 B Before using the air conditioner , please read this manual car efully . Please keep this manual properly for future use. ...

  • Haier HBU-18CF03 - page 2

    Contents Cautions ........................................................................................... Introduction to Spare Parts ................................................................ Maintenance ................................................................................... T rouble Shooting ................................. ...

  • Haier HBU-18CF03 - page 3

    Cautions 1 Disposal of the old air conditioner Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The v ...

  • Haier HBU-18CF03 - page 4

    2 All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner . Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting an ...

  • Haier HBU-18CF03 - page 5

    Cautions W ARNING! Carefully r ead the following information in order to operate the airconditioner correctly . Below are listed three kinds of Safety Cautions and Suggestions. W ARNING! CAUTION! Incorrect operations may result in injuries or machine damages; in some cases may cause serious consequences. Incorrect operations may result in severe co ...

  • Haier HBU-18CF03 - page 6

    Cautions CAUTIONS! Conditioner should not be used for any other purpose other than air conditioning. Don't use air-conditioner for any other special purposes, e.g. the preservation and protection of food, animals, plants, pecision apparatus as well as work of art, otherwise the qualities of these stuffs may be damaged. Don't dismantle the ...

  • Haier HBU-18CF03 - page 7

    W ARNING ! CAUTION ! Please ask the dealer or specialist to install, never try by the users themselves. After the installation please be sure of the following conditions. Incorrect installation may cause water leaking, shock and fire hazard. Please call dealer to install the air -conditioner . Air -conditioner can't be installed in the envi- r ...

  • Haier HBU-18CF03 - page 8

    Intr oduction to Spar e Parts Swing fender Air filter Outlet Suction grill (located in the suction grill) (located in the outlet) Indoor unit 6 ...

  • Haier HBU-18CF03 - page 9

    3. Dismantle air filter CAUTION! 4. Clean 6. Close inlet grill 7. Press the filter signal return key on the controller . (A) Remove dust with vacuum filter . 5. Install air filter (1) Put filter into protruding parts at the top of the inlet grill. (2) Connect the two pothooks with inlet grill See 2 [Clean inlet grill] 1. Open inlet grill See 1. Con ...

  • Haier HBU-18CF03 - page 10

    8 3. T ake of inlet grill 4. Clean CAUTION! NOTE When the filter too much dust T o spray the special deter gent for vent fan or utensils. 5. Install inlet grill 6. Install air filter 7. Close inlet grill [Clean outlet and shell] see 3 see "Clean air filter" see 1 CAUTION! Don't use gasoline, benzene, dilutant, polishing powder , or l ...

  • Haier HBU-18CF03 - page 11

    9 NOTE 1.The inner part of indoor unit must be cleaned. Consult dealer , because clean must be done by technician. 2.In cooling operation, discharging system dischar ge water in room. Seasonal Reserve Operate the unit with F AN mode on a fair day for about half a day to dry the inside of the unit well. Stop operation and turn off the power supply s ...

  • Haier HBU-18CF03 - page 12

    10 The followings ar e not malfunction Hua Hua T r ouble Shooting W ater flowing sound is heard When the air conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it sometimes sounds  Bi- Bi- or Godo-Godo. It is the flowing sound of the refrigerant , not a malfunction. Crackin ...

  • Haier HBU-18CF03 - page 13

    11 **? ON OFF T r ouble Shooting Air does not blow or the fan speed cannot be changed during drying. In DR Y mode, when room temperature becomes 2 ¡ higher than temperature setting, unit rill run intermittently at LO speed regardless of F AN setting During heating,indoor fan is still running even unit is stopped. T o get ride of the excess heat, i ...

  • Haier HBU-18CF03 - page 14

    12 When T rouble Happens Insufficient cooling or heating The operation controller adjusted as required Air filter too dirty ? Horizontal swing louver upward ? (in HEA T mode) Any obstacle exists at the air inlet or outlet? Door or window left opened ? Insufficient cooling Any other heat sources in the room? Sunlight direct into the room ? T oo crow ...

  • Haier HBU-18CF03 - page 15

    13 When T rouble Happens The exterior alarm signal input "Run" light flashes eleven times The indoor coil temperature is higher than room temperature when cooling or the former is lower than the later when heating "Run" light flashes thirteen times BM1 (1) OFF (2)OFF BM2 BM3 BM4 (1) OFF (2)OFF (Cooling only unit) (1) OFF (2)ON ( ...

  • Haier HBU-18CF03 - page 16

    14 Customer Need-to-know Customer Need-to-know Please install the air conditioner according to the requirements specified in this manual to ensure the air conditioner work well. Be careful not to scratch the surface of the case during moving the air conditioner . Please keep the installation manual for future reference when maintenance and changing ...

  • Haier HBU-18CF03 - page 17

    15 Installation tools 1. Screw driver 2. Hacksaw 3. Drill with a diameter of 60mm 4. Inner hexagon spanner ,shifting spanner 5. Spanner (14, 17, 19, 24, 27mm) 6. Pipe cutter 7. Pipe expander 8. Knife 9. Pincers 10. Leakage detector or soapy water 1 1. Band tape 12. Scraper 13. Refrigerant oil The installation tools listed in the following sheet can ...

  • Haier HBU-18CF03 - page 18

    16 Unit shall be grounded. But grounding shall not be connected to gas pipe water pipe, telephone line. Poor grounding will cause electric shock. Be sure to install a leakage breaker to avoid electric shock. Arrange water drainage according to this Manual. Cover pipe with insulation materials in case dew may occur . Unproper installation of water d ...

  • Haier HBU-18CF03 - page 19

    17 (2) Ceiling height Indoor unit can be installed on ceiling of 2.5-3m in height. (Refer to Field setting and Installation Manual of ornament panel.) (3) Install suspending bolt. Check if the installation place is strong enough to hold weight. T ake necessary measures in case it is not safe. (Distance between holes are marked on paper pattern. Ref ...

  • Haier HBU-18CF03 - page 20

    18 (2) Cut an opening in ceiling for installation if necessary . (when ceiling already exists.) (3) Install a suspending bolt. (Use a M10 bolt) T o support the unit weight, anchor bolt shall be used in the case of already exists ceiling. For new ceiling, use built-in type bolt or parts prepared in the field. Before going on installing adjust space ...

  • Haier HBU-18CF03 - page 21

    19 ( As for outdoor piping, please refer to installation Manual of outdoor unit. ) Outdoor is precharged with refrigerant. Be sure to see the Fig.1, when connecting and removing piping from unit. For the size of the flare nut, please refer to T able 1. Apply refrigerant oil at both inside and outside of flare nut. T ighten it band tight 3-4 turns t ...

  • Haier HBU-18CF03 - page 22

    20 Check if water drainage is smooth after installation. Charge, through air outlet or inspecting hole, 1200cc water to see water drainage. (1) Install water drainage pipe Pipe dia, shall be equal or larger than that of unit piping.(pipe of polyethylent; size: 25mm; O.D:32mm) Drain pipe should be short, with a downward slope at least 1/100 to preve ...

  • Haier HBU-18CF03 - page 23

    21 As for outdoor unit circuit, please see Installation Manual of outdoor unit. Note: All electric wires have their own poles, poles must match that on terminal block. 9. INST ALLA TION OF ORNAMENT P ANEL Be sure to show customers Operation Manual and guide them how to operate unit correctly . Before installation. read also the Installation Manual ...

  • Haier HBU-18CF03 - page 24

    22 Item to the checked Pay special care to the following and check after installation Unproper installation may cause Check Is indoor unit firmly installed? Is gas leakage check performed? Is unit properly insulated? Is water drainage smooth? Is power voltage meet that stipulated on the nameplate? Is wiring and piping correctly arranged? Is unit sa ...

メーカー Haier カテゴリー Air Conditioner

Haier HBU-18CF03のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- HBU-18CF03の取扱説明書
- Haierの製品カード
- パンフレット
- またはHaier HBU-18CF03の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Haier HBU-18CF03の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Haier HBU-18CF03の取り付け説明書、サービスマニュアル、簡易説明書、またはHaier HBU-18CF03のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Haier HBU-18CF03の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Haier HBU-18CF03デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHaier HBU-18CF03を使用するのを助ける技術的文書のことです。説明書は通常、全てのHaier HBU-18CF03ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Haierの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Haier HBU-18CF03の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHaier HBU-18CF03の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Haier HBU-18CF03に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Haier HBU-18CF03デバイスの基本機能を使うにあたってのヒント。 Haier HBU-18CF03のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Haier HBU-18CF03に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHaier HBU-18CF03のメーカー/サービスへの連絡先に関する情報。

Haier HBU-18CF03についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHaier HBU-18CF03の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHaier HBU-18CF03で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください