  • American Dryer Corp. AD-670 - page 1

    For replacement parts, contact the reseller from which the dryer was purchased or American Dryer Corporation 88 Currant Road Fall River, MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 E-mail: techsupport@amdr y .com www.amdr y .com 103100GS/tcosta ADC Part No. 113049 AD-670 Installation Manual Phase 7 / Gas Only WARNING: For your saf ...

  • American Dryer Corp. AD-670 - page 2

    Retain This Manual In A Safe Place For Future Reference American Dryer Corporation products embody advanced concepts in engineering, design, and safety. If this product is properly maintained, it will provide many years of safe, efficient, and trouble-free operation. ONLY qualified technicians should service this equipment. OBSERVE ALL SAFETY PRECA ...

  • American Dryer Corp. AD-670 - page 3

    IMPOR TANT YOU MUST DISCONTINUE AND LOCKOUT THE ELECTRIC SUPPL Y AND THE GAS SUPPL Y BEFORE ANY COVERS, GUARDS, OR DOORS ARE REMOVED OR OPENED T O ALLOW ACCESS FOR CLEANIN G , ADJUSTIN G , INST ALLA TION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Administration) STANDARDS. CHILDREN SHOULD NOT BE ALLOWED TO PL AY ON OR NEA ...

  • American Dryer Corp. AD-670 - page 4

    WARNING IMPOR TANT PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment or specified in the installation manual included with the drye r. Dryers must not be installed or stored in an area where it will be exposed to water or weather. The wiring diagram for the dryer is located in the left front electrical control cabinet. DRYER MUST NEV ...

  • American Dryer Corp. AD-670 - page 5

    Table of Contents SECTION I IMPOR TANT INFORM ATION ............................................................................ 3 A. Receiving and Handling ........................................................................................................... 3 B. Safety Precautions ............................................................. ...

  • American Dryer Corp. AD-670 - page 6

    SECTION VII DATA LABEL INFORM ATION .......................................................................... 29 A. Data Label ........................................................................................................................... 29 SECTION VIII GAS TRAIN AND BURNER DESCRIPTION AND OPER ATION ................. 31 A. Pilot Gas ...

  • American Dryer Corp. AD-670 - page 7

    3 SECTION I IMPOR T ANT INFORMA TION A. RECEIVING AND HANDLING The dryer is shipped in three (3) pieces with protective stretch wrap, protective cardboard corners, and top covers as a means of preventing damage in transit. Upon delivery, the individual pieces and/or packaging, and wooden skids should be visually inspected for shipping damage. If an ...

  • American Dryer Corp. AD-670 - page 8

    4 B. SAFETY PRECAUTIONS WARNING: For your safet y , the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injur y , or loss of life. WARNING: The dryer must never be operated with any of the safety guards, service panels, or service doors removed or open. PERSONAL INJURY OR ...

  • American Dryer Corp. AD-670 - page 9

    5 WARNING: DO NOT use heat for drying articles that contain plastic, foam, sponge rubber, or similarly textured rubberlike materials. Drying in a heated basket (tumbler) may damage plastics or rubber and may be a fire hazard. 7. A program should be established for the inspection and cleaning of lint in the burner area, exhaust ductwork, and area ar ...

  • American Dryer Corp. AD-670 - page 10

    6 SECTION II SPECIFICA TIONS AND DIMENSIONS A. SPECIFICA TIONS NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation. Gas Maximum Capacity (Dry Weight) 670 lb 303.9 kg Basket Diameter 78-1/4" 198.8 cm Basket Depth 92" 233.7 cm Basket Volume 256 cu ft 7.25 cu m Blower Motor 2 x 5 hp 2 x 3.7 ...

  • American Dryer Corp. AD-670 - page 11

    7 AD-670 1 Door Tilting/2 Door Tilting B. DIMENSIONS NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation. ...

  • American Dryer Corp. AD-670 - page 12

    8 SECTION III INST ALLA TION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.1- LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70-L A TEST EDITION (National Electr ...

  • American Dryer Corp. AD-670 - page 13

    9 B. FRESH AIR SUPPL Y REQUIREMENTS When the dryer is operating, it draws in room air, heats it, passes this air through the basket (tumbler), and exhausts it out of the building. Therefore, the room air must be continually replenished from the outdoors. If the make-up air is inadequate, drying time and efficiency will be adversely affected. Igniti ...

  • American Dryer Corp. AD-670 - page 14

    10 IMPOR TANT: Make-up air must be provided from a source free of dry cleaning solvent fumes. Make-up air that is contaminated by dry cleaning solvent fumes will result in irreparable damage to the motors and other dryer components. NOTE: Component failure due to dry cleaning solvent fumes will VOID THE WARRANTY . C . EXHAUST REQUIREMENTS IMPOR TAN ...

  • American Dryer Corp. AD-670 - page 15

    11 IMPOR TANT: Exhaust back pressure measured by a Magnehelic in the exhaust duct must be no less than 0 and must not exceed 1.0 inch (2.48 mb) of water column ( W .C.). NOTE: When the exhaust ductwork passes through a wall, ceiling, or roof made of combustible materials, the opening must be 2-inches (5.08 cm) larger than the duct (all the way arou ...

  • American Dryer Corp. AD-670 - page 16

    12 ...

  • American Dryer Corp. AD-670 - page 17

    13 D. ELECTRICAL REQUIREMENTS It is your responsibility to have ALL electrical connections made by a properly licensed and competent electrician to assure that the electrical installation is adequate and conforms to local and state regulations or codes. In the absence of such codes, ALL electrical connections, materials, and workmanship must confor ...

  • American Dryer Corp. AD-670 - page 18

    14 WARNING: 208 VAC AND 240 VAC ARE NOT THE SAME . Any damage done to the dryer components due to improper voltage connections will automatically VOID THE WARRANTY . NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation. 2. Electrical Connections NOTE: A wiring diagram is included with each dryer an ...

  • American Dryer Corp. AD-670 - page 19

    15 E. GAS REQUIREMENTS It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gas plumbing installation is adequate and conforms to local and state regulations or codes. In the absence of such codes, ALL plumbing connections, materials, and workmanship must conform to the applicable requiremen ...

  • American Dryer Corp. AD-670 - page 20

    16 2. Technical Gas Data a. Gas Specifications * Measured at the gas valve pressure tap when the gas valve is on. b. Gas Connections Run a 2-inch gas pipe from the main gas header to the dryer. There is a 2-inch gas pipe connection at the bottom of the dryer base. Inlet Connection ................... 2” F.P.T. BTU/hr input (per dryer) ...... 2,20 ...

  • American Dryer Corp. AD-670 - page 21

    17 3. Piping /Connections ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-L A TEST EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L. P .] Gas) or L A TEST EDITION (for General Installation and Gas Plumbing), as well as local codes and ordinances and must be d ...

  • American Dryer Corp. AD-670 - page 22

    18 Consistent gas pressure is essential at ALL gas connections. It is recommended that a 2-inch (5.08 cm) pipe gas loop be installed in the supply line servicing a bank of dryers. An in-line pressure regulator must be installed in the gas supply line (header) if the (natural) gas pressure exceeds 12.0 inches (29.9 mb) of water column ( W .C.) press ...

  • American Dryer Corp. AD-670 - page 23

    19 G . PREOPERA TIONAL TESTS ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or due to marginal location (installation) conditions. 1. Turn on electric power to the dryer. 2. Make s ...

  • American Dryer Corp. AD-670 - page 24

    20 NOTE: Mechanical functions of the dryer are not allowed during the ON time. The blower (fan) must be OFF to perform mechanical functions. However the “STOP/CLEAR” key may be pressed at any time to end the Wrinkle Guard cycle. Mechanical functions of the dryer are allowed during the OFF time. NOTE: Dryer can be stopped at any time by opening ...

  • American Dryer Corp. AD-670 - page 25

    21 12. Make a complete operational check of ALL safety-related circuits (i.e., lint drawer, door, and sail switches on gas models). 13 . A reversing basket (tumbler) should never be operated with less than a 442 lb (200 kg) load (dry weight). The size of the load will affect the coast-down and dwell (stop) times. The basket (tumbler) must come to a ...

  • American Dryer Corp. AD-670 - page 26

    22 NOTE: Lint drawer must be ALL the way in place to activate the safety switch otherwise the dryer will not start. 9. Check bolts, nuts, screws, terminals, and fittings for security. 10. Check to ensure air supply (80 PSI [5.51 bars]) is connected to the dryer. I . SHUT DOWN INSTRUCTIONS If the dryer is to be shut down (taken out of service) for a ...

  • American Dryer Corp. AD-670 - page 27

    23 SECTION IV ROUTINE MAINTENANCE A. CLEANING A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer, as well as throughout the ductwork system. The frequency of cleaning can best be determined from experience at each location. Maximum operating efficiency is dependent ...

  • American Dryer Corp. AD-670 - page 28

    24 MONTHLY Empty the compressed air filter bowl. Apply high-temperature grease to the four (4) 2-3/16” diameter basket (tumbler) drive shaft pillow block bearings. ( Use Shell Alvania #2 grease or its equivalent .) Retighten setscrews in the collars of the four (4) 2-3/16” diameter basket (tumbler) drive shaft bearings. Clean any lint accumulat ...

  • American Dryer Corp. AD-670 - page 29

    25 B. ADJUSTMENTS 7 DA YS AFTER INST ALLA TION AND EVER Y 6 MONTHS THEREAFTER Inspect bolts, nuts, screws (bearing setscrews), grounding connections, and nonpermanent gas connections (i.e., unions, shutoff valves, and orifices). Fan (impellor) V -belts, along with the motor and drive chains should be examined and replaced if necessary. Tighten loos ...

  • American Dryer Corp. AD-670 - page 30

    26 SECTION V SER VICE/P AR TS INFORMA TION A. SER VICE 1. Service must be performed by a qualified trained technician, service agency, or gas supplier. If service is required, contact the reseller from whom the ADC equipment was purchased. If the reseller cannot be contacted or is unknown, contact the ADC Service Department for a reseller in your a ...

  • American Dryer Corp. AD-670 - page 31

    27 SECTION VI WARRANTY INFORMA TION A. RETURNING W ARRANTY CARDS 1. Before any dryer leaves the ADC factory test area, a warranty card is placed on the back side of the main door glass. These warranty cards are intended to serve the customer where we record the individual installation date and warranty information to better serve you should you fil ...

  • American Dryer Corp. AD-670 - page 32

    28 2. Each part must be tagged with the following information: a. Model number and serial number of the dryer from which part was removed. b. Nature of failure (be specific). c. Date of dryer installation. d. Date of part failure. e. Specify whether the part(s) being returned is for a replacement, a credit, or a refund. NOTE: If a part is marked fo ...

  • American Dryer Corp. AD-670 - page 33

    29 SECTION VII DA T A LABEL INFORMA TION A. DA T A LABEL Contact American Dryer Corporation When contacting American Dryer Corporation certain information is required to insure proper service/parts information from ADC . This information is on the data label that is affixed to the left side of the main electrical cabinet located in the right hand e ...

  • American Dryer Corp. AD-670 - page 34

    30 THE D ATA LABEL 1. MODEL NUMBER The model number is an ADC number, which describes the size of the dryer and the type of heat (gas, electric, or steam). 2. SERIAL NUMBER The serial number allows ADC to gather information on your particular dryer. 3. MANUFACTURING CODE NUMBER The manufacturing code number is a number issued by ADC, which describe ...

  • American Dryer Corp. AD-670 - page 35

    31 SECTION VIII GAS TRAIN AND BURNER DESCRIPTION AND OPERA TION The ADG-670’s atmospheric burner system is responsible for supplying the dryer with it’s heat input. It is a high/low system with a firing rate of 2.2 million BTUs per hour (554,400 kcal/hr) on hi-fire and 450,000 BTUs per hour (113,400 kcal/hr) on lo-fire. This system consists of ...

  • American Dryer Corp. AD-670 - page 36

    32 2. 1/2” N. P .T. Pilot Solenoid V alve – This is an on/off solenoid valve which is used to allow gas to flow through the line when pilot is called for and then discontinues gas when the heat cycle has been completed. There is no adjustment needed to this valve for natural or liquid propane (L. P .) gases. 3. 1/2” N. P .T. Adjustable Orific ...

  • American Dryer Corp. AD-670 - page 37

    33 B. MAIN GAS SUPPL Y LINE The main gas supply line is a 2” N. P .T. line, which feeds the gas required for both high and lo-fire. 1. Main Gas V alve - The main gas valve is a double solenoid gas valve containing two (2) safety shutoff valves in one (1) housing. It is a fast opening, fast close valve and is used to feed both high and lo-fire gas ...

  • American Dryer Corp. AD-670 - page 38

    34 C. LO-FIRE GAS SUPPL Y LINE LOOP The lo-fire gas supply line loop is a 3/4” line, which is responsible for supplying the burner system with the gas required during lo-fire operation. 1. Adjustable Orifice - The adjustable orifice found in the lo-fire gas supply line controls the flow of gas to the burner during lo-fire. a. Adjustable Orifice L ...

  • American Dryer Corp. AD-670 - page 39

    35 SECTION IX COMPONENT SYSTEM DESCRIPTIONS A. BASKET (TUMBLER) DRIVE SYSTEM There are two (2) drive assemblies. Each drive assembly consists of a 5 HP (3.72 kw) drive motor, which is connected to the drive shaft by two (2) “B” section V -belts, driving a shaft-mounted (5.6 to 1 ratio) gear reducer. This produces a basket (tumbler) speed of app ...

  • American Dryer Corp. AD-670 - page 40

    36 B. BASKET (TUMBLER) The basket (tumbler) is made of 14-gauge stainless steel perforated panels, five (5) stainless steel ribs, and two (2) basket (tumbler) rings. The basket (tumbler) ribs are welded at each end to the basket (tumbler) rings. The perforated panels are bolted to the ribs so that they can be removed for cleaning or replaced. C. BL ...

  • American Dryer Corp. AD-670 - page 41

    37 4. Burner Box Hi-Limit Safety Thermostats (for Gas Models Only) These disc temperature switches have a setting of 330º F (166º C). They are located on the right side of each burner box, and they are a manual reset type of switch. These switches ensure that there is proper airflow through the burner box. Upon a low airflow condition, which may ...

  • American Dryer Corp. AD-670 - page 42

    38 SECTION X PHASE 7 OPL SYSTEM DIAGNOSTICS IMPOR TANT: YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPL Y AND THE GAS SUPPL Y BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE T O ALLOW ACCESS FOR CLEANIN G , ADJUSTIN G , INST ALLA TION, OR TESTING OF ANY EQUIPMENT PER OSHA ( Occupational Safety and Health Administration ) ST ANDARDS. ALL ...

  • American Dryer Corp. AD-670 - page 43

    39 CALL FOR SERVICE - Indicates a board failure. FRONT DOOR NOT CLOSED - A front door is open when it should be closed. REAR DOOR NOT CLOSED - A rear door is open when it should be closed. CHECK CONTROL POWER - Indicates control power is off. EXHAUST HIGH TEMP FAULT - Indicates the temperature in the basket (tumbler) is above 225º F (107º C). LIN ...

  • American Dryer Corp. AD-670 - page 44

    40 B. I/O BOARD INPUT AND OUTPUT L.E.D. INDICA T ORS ...

  • American Dryer Corp. AD-670 - page 45

    41 Input/Output (I/O) Board Input Description (“Red” light emitting diode [L.E.D.]) 1. FDRC – (RED L.E.D.) This L.E.D. will indicate the status of the Front Doors. If the doors are closed, then the L.E.D. is ON. 2. FDRO – (RED L.E.D.) This L.E.D. will indicate the status of the Front Doors. If the doors are open, then the L.E.D. is ON. 3. T ...

  • American Dryer Corp. AD-670 - page 46

    42 8. RDRO – (RED L.E.D.) This L.E.D. will indicate the status of the Rear Doors. If the doors are open, then the L.E.D. is ON. 9. FAN – (RED L.E.D.) This L.E.D. will indicate the status of the Blower Fan. If the fan is on, then the L.E.D. is ON. 10. RBHL – (RED L.E.D.) This L.E.D. will indicate the status of the Rear Burner Hi-Limit Disk. If ...

  • American Dryer Corp. AD-670 - page 47

    43 Input/Output (I/O) Board Output Description (“Green” light emitting diode [L.E.D.]) 1. R_HE A T – (GREEN L.E.D.) This L.E.D. will indicate the status of the Rear Heat output. If the request to turn on the Rear Burner is made, then the L.E.D. is ON. 2. ALERT – (GREEN L.E.D.) This L.E.D. will indicate the status of the Horn output. If the ...

  • American Dryer Corp. AD-670 - page 48

    44 16. OCL5 – (GREEN L.E.D.) This L.E.D. will indicate the status of the Open Collector #5 output. If the request to turn on the Open Collector #5 is made, then the L.E.D. is ON. (Programmable and Defaulted to Rear Down.) 17. OCL6 – (GREEN L.E.D.) This L.E.D. will indicate the status of the Open Collector #6 output. If the request to turn on th ...

  • American Dryer Corp. AD-670 - page 49

    45 SECTION XI TROUBLESHOOTING IMPOR TANT: YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPL Y AND THE GAS SUPPL Y BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE T O ALLOW ACCESS FOR CLEANIN G , ADJUSTIN G , INST ALLA TION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Administration) STANDARDS. The information prov ...

  • American Dryer Corp. AD-670 - page 50

    46 NOTE: SPRINKLER MUST H AVE POWER FOR THE DRYER TO OPER A TE. B. Drive motor is not operating ( does not start)... * Microprocessor controller (computer) relay output indicator (either forward “FWD” or reverse “REV”) is on. 1. Blown drive motor contactor overloads. 2. Failed drive motor contactor. 3. Failed drive motor. 4. No 24 VAC prese ...

  • American Dryer Corp. AD-670 - page 51

    47 f. V -belts are too tight. g. Dryer has an oversized load. h. V oltage to the dryer is incorrect...check dryer data label for specified voltage. 2. Failed overload protector... a. Incorrect overload setting. E. Impellor (fan) motor is not operating ( does not start)... * Microprocessor controller (computer) input/output (I/O) board “FAN” rel ...

  • American Dryer Corp. AD-670 - page 52

    48 2. Failed overload protector... a. Incorrect overload setting. 3. Blown drive motor and blower (fan and impellor) motor fuses or overloads. 4. Failed motors (both blower [fan and impellor] motor and drive motor). 5. Failed microprocessor controller (computer). G. Microprocessor controller (computer) display board light emitting diode (L.E.D.) di ...

  • American Dryer Corp. AD-670 - page 53

    49 5. Front or rear doors are opened during cycle. 6. Failed microprocessor controller (computer) input/output (I/O) board. J. Microprocessor controller (computer) light emitting diode (L.E.D.) displays “Lint Drawer Open.” 1. Lint drawer is not closed ALL the way. 2. Lint drawer switch is out of proper adjustment. 3. Failed lint drawer switch. ...

  • American Dryer Corp. AD-670 - page 54

    50 2) Failure in drive motor circuit. b. Faulty rotation sensor. c. Broken wire or connection between rotation sensor and microprocessor controller (computer) display board. d. Failure in rotational sensor circuit, magnet missing, or gap too large. e. Basket (tumbler) rotation below 12 RPMS. P. Microprocessor controller (computer) reads “Exhaust ...

  • American Dryer Corp. AD-670 - page 55

    51 2. Impellor (fan/blower) out of balance... a. Excessive lint buildup on impellor (fan/blower)...check air jet. b. Failed impellor (fan/blower). 3. Loose motor mount. 4. Failed idler bearings or basket (tumbler) bearings. 5. V -belt(s) either too tight or too loose. 6. Basket (tumbler) drive wheels are worn or are loose. 7. Setscrews of basket (t ...

  • American Dryer Corp. AD-670 - page 56

    52 SECTION XII OPTIONAL SPRINKLER SYSTEM COMPONENTS OPTIONAL SPRINKLER CIRCUIT COMPONENTS AUT O “EMERGENCY ST OP” ( E-Stop ) RELA Y This device, located in the front right electrical enclosure, supplies the main control voltage to the dryer. The dryer’s sprinkler circuit supplies or removes 120 VAC to the coil of this relay for the “EMERGEN ...

  • American Dryer Corp. AD-670 - page 57

    53 SPRINKLER AND MAIN POWER CONNECTIONS There are two (2) individual power connections to the dryer that includes the sprinkler system option. 1. Main dryer power (3-phase [3ø]). 2. Dedicated sprinkler system circuit power (single-phase [1ø]). Both of these connections are at the voltage rating of the dryer and can be installed in the front right ...

  • American Dryer Corp. AD-670 - page 58

    54 Sprinkler Option Temperature Controller Settings NOTE: Refer to Controlle r ’s Use r ’s Manual for further information on controller options. Note: When message display (Cy) set to OnOF. SPOL (SET POINT OUTPUT LOW LIMIT) not in use. SPOH (SET POINT OUTPUT HIGH LIMIT) not in use. Are not displayed. Message Display Message Description Settings ...

  • American Dryer Corp. AD-670 - page 59

    55 ...

  • American Dryer Corp. AD-670 - page 60

    ADC 113049 5 - 09/03/04-0 ...

メーカー American Dryer Corp. カテゴリー Clothes Dryer

American Dryer Corp. AD-670のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AD-670の取扱説明書
- American Dryer Corp.の製品カード
- パンフレット
- またはAmerican Dryer Corp. AD-670の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、American Dryer Corp. AD-670の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、American Dryer Corp. AD-670の取り付け説明書、サービスマニュアル、簡易説明書、またはAmerican Dryer Corp. AD-670のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、American Dryer Corp. AD-670の製品を使用するにあたって最も人気のある説明書を閲覧できます。

American Dryer Corp. AD-670デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAmerican Dryer Corp. AD-670を使用するのを助ける技術的文書のことです。説明書は通常、全てのAmerican Dryer Corp. AD-670ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

American Dryer Corp.の取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. American Dryer Corp. AD-670の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAmerican Dryer Corp. AD-670の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。American Dryer Corp. AD-670に関してこのドキュメントで見つけることができる全てのヒントの目次
3. American Dryer Corp. AD-670デバイスの基本機能を使うにあたってのヒント。 American Dryer Corp. AD-670のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。American Dryer Corp. AD-670に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAmerican Dryer Corp. AD-670のメーカー/サービスへの連絡先に関する情報。

American Dryer Corp. AD-670についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAmerican Dryer Corp. AD-670の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAmerican Dryer Corp. AD-670で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)