  • Metrologic Instruments MX009 - page 1

    ...

  • Metrologic Instruments MX009 - page 2

    Copyright © 2005 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Products and brand names mentioned in this docume ...

  • Metrologic Instruments MX009 - page 3

    ii T ABLE O F C ONTENTS Introduction How does the MX009 U SB Cable Operate?...................................................... 1 What is the difference between USB Keyboard Emulation and USB Serial Emulation? ...................................................................................... 1 How is the MX009 Configured fo r USB Keyboard Emu ...

  • Metrologic Instruments MX009 - page 4

    ...

  • Metrologic Instruments MX009 - page 5

    1 I NTRODUCTION Metrologic’s MX009 USB Cable is a device that converts serial RS232 formatted data to either USB Keyboard or USB Serial communication protocol. The MX009 can be used with all Metrologic products equipped with an RS232 interface, as well as all versions of Metrologic PowerLink compatible scanners. All versions of Metrologic’s Pow ...

  • Metrologic Instruments MX009 - page 6

    2 I NTRODUCTION • H OW IS THE MX009 CONFIGURED FOR USB KEYBOARD E MULATION ? This guide contains the configuration bar codes necessary to ensure that the scanner communicates properly with the MX009. The scanner communicates using RS232 protocol. The default (RS232) settings of the scanner are as follows: • For Non-PowerLink Scanners 9600 baud, ...

  • Metrologic Instruments MX009 - page 7

    3 I NTRODUCTION (C ONT .) • H OW IS THE MX009 CONFIGURED FOR USB S ERIAL E MULATION ? This guide contains the configuration bar codes necessary to ensure that the scanner communicates properly with the MX009. The scanner communicates using RS232 protocol. The default (RS232) settings of the scanner are as follows: • For Non-PowerLink Scanners 9 ...

  • Metrologic Instruments MX009 - page 8

    4 MX009 USB C ABLE O PTIONS P ART N UMBER C ONNECTOR T YPE S TRAIGHT C OILED USB E ND S CANNER E ND C OMPATIBLE S CANNER M ODELS Discontinued scanner models are shown in grey. S MX009-2MA7 C Type A 10-pin RJ45 Male All versions of the: MS6220, MS6520, IS6520, MS7100, MS7220, MS9500, MS3580 and IS3580 S MX009-2FA7 C Type A 10-pin RJ45 Female MS6720- ...

  • Metrologic Instruments MX009 - page 9

    5 MX009 P ART N UMBER D ESIGNATION AND A CCESSORIES P ARTS AND A CCESSORIES Part No. Description MX009 USB Converter Cable MX009-2 xx 7 x USB Keyboard Emulation Cable MX009-2 xx 8 x USB Serial Emulation Cable P ART N UMBER D ESIGNATION Application Dependent AC to DC Power Transformer (Optional) 00-02574 X MX009 USB Converter Cable Configuration Gui ...

  • Metrologic Instruments MX009 - page 10

    6 C ABLE I NSTALLATION Make sure the AC input requirements of the power supply match the AC outlet. The outlet should be near the equipment and easily accessible. ...

  • Metrologic Instruments MX009 - page 11

    7 L ABELS Each MX009 has CE, UL and caution information embedded in the back of the case. The following is an example of embedded information. Figure 1. Each MX009 will also have a flag tag attached to the cable with the date of manufacture, model number, and serial number. Figure 2. ** Illustrations shown are not actual size. ...

  • Metrologic Instruments MX009 - page 12

    8 C ONFIGURING FOR USB K EYBOARD E MULATION (MX009-2 XX 7 X ) PowerLink Compatible Scanners These Metrologic Scanners, used with the MX009 Cable must be reconfigured using the following bar codes before the MX009 can communicate properly with a host system. • MS9500 Voyager ® Series • MS6220 Pulsar ® • MS7100 Orbit ® • MS3580 QuantumT ? ...

  • Metrologic Instruments MX009 - page 13

    9 C ONFIGURING FOR USB K EYBOARD E MULATION (MX009-2 XX 7 X ) 4. Scan the appropriate bar code below to set USB Keyboard Emulation to the country keyboard required ( defaults to USA ). USA ³ 416260 S WITZERLAND ³ 416280 S PAIN ³ 416250 I TALY ³ 416240 G ERMANY ³ 416230 F RANCE ³ 416220 Continued on next page. ...

  • Metrologic Instruments MX009 - page 14

    10 C ONFIGURING FOR USB K EYBOARD E MULATION (MX009-2 XX 7 X ) U NITED K INGDOM ³ 416210 B ELGIUM ³ 416200 J APANESE ³ 4162100 IBM 4700 F INANCIAL K EYBOARD ³ 416270 S WEDEN /F INLAND ³ 416290 5. E NTER /E XIT C ONFIGURATION M ODE ³ 999999 ...

  • Metrologic Instruments MX009 - page 15

    11 C ONFIGURING FOR USB K EYBOARD E MULATION (MX009-2 XX 7 X ) MS6720, MS860, AND T ECH S ERIES These Metrologic Scanners, used with the MX009 Cable must be reconfigured using the following bar codes before the MX009 can communicate properly with a host system. • MS6720 • MS860 • Tech Series Note: Configuration for USB Keyboard Emulation must ...

  • Metrologic Instruments MX009 - page 16

    12 C ONFIGURING FOR USB K EYBOARD E MULATION (MX009-2 XX 7 X ) 4. E NABLE XON/OFF H ANDSHAKING 0 12345 11714 5 5. E NABLE ACK/NAK 0 12345 11713 8 6. C ONFIGURABLE P REFIX #1 0 12345 92000 4 7. C ONTROL V P REFIX 0 12345 00022 5 8. C ONFIGURABLE P REFIX #2 0 12345 92100 1 Continued on next page. ...

  • Metrologic Instruments MX009 - page 17

    13 C ONFIGURING FOR USB K EYBOARD E MULATION (MX009-2 XX 7 X ) 9. Scan one of the following bar codes to set Keyboard Emulation. B ELGIUM 0 12345 00065 2 U NITED K INGDOM 0 12345 00066 9 F RENCH 0 12345 00067 6 G ERMAN 0 12345 00068 3 I TALIAN 0 12345 00069 0 Continued on next page. ...

  • Metrologic Instruments MX009 - page 18

    14 C ONFIGURING FOR USB K EYBOARD E MULATION (MX009-2 XX 7 X ) S PANISH 0 12345 00070 6 U NITED S TATES 0 12345 00071 3 S WISS 0 12345 00073 7 S WEDISH /F INNISH 0 12345 00074 4 J APANESE 0 12345 00075 1 Continued on next page. ...

  • Metrologic Instruments MX009 - page 19

    15 C ONFIGURING FOR USB K EYBOARD E MULATION (MX009-2 XX 7 X ) R ESERVED 0 12345 00076 8 10. E NTER /E XIT C ONFIGURATION M ODE 0 12345 66666 7 ...

  • Metrologic Instruments MX009 - page 20

    16 C ONFIGURING FOR USB S ERIAL E MULATION (MX009-2 XX 8 X ) PowerLink Compatible Scanners These Metrologic scanners must be reconfigured using the following bar codes before the MX009 can communicate properly with the host system. • MS9500 Voyager Series • MS6220 Pulsar • MS7100 Orbit • MS3580 QuantumT • MS7220 Argus SCAN • IS3480 Quan ...

  • Metrologic Instruments MX009 - page 21

    17 C ONFIGURING FOR USB S ERIAL E MULATION (MX009-2 XX 8 X ) MS6720, MS860, AND TECH SERIES These Metrologic scanners must be reconfigured using the following bar codes before the MX009 can communicate properly with a host system. • MS6720 • MS860 • Tech Series Note: Configuration for USB Serial Emulation must be completed before enabling/dis ...

  • Metrologic Instruments MX009 - page 22

    18 C ONFIGURING FOR USB S ERIAL E MULATION (MX009-2 XX 8 X ) 4. E NABLE XON/XOFF H ANDSHAKING 0 12345 11714 5 5. E NABLE ACK/NAK 0 12345 11713 8 6. E NTER /E XIT C ONFIGURATION M ODE 0 12345 66666 7 ...

  • Metrologic Instruments MX009 - page 23

    19 T ROUBLESHOOTING G UIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited warranty terms on page 22. Test Bar Code Scanning the following bar code will transmit the encoded characters followed by the software number of the MX009. Mt Lg -m x 009 S YM ...

  • Metrologic Instruments MX009 - page 24

    20 S PECIFICATIONS MX009 USB C ONVERTER C ABLE S PECIFICATIONS M ECHANICAL Dimensions: 80.4 mm (3.2”) L x 32.4 mm (1.3”) W x 18.7 mm (0.7”) H Weight: 160 g (0.35 lb) Termination: 10-pin modular RJ45 Male to USB 10-pin modular RJ45 Female to USB. 25-pin Female D-Sub to USB Cable: Straight or Coiled E LECTRICAL Input Voltage: 5.0 VDC ± 0.25V E ...

  • Metrologic Instruments MX009 - page 25

    21 C ABLE I NFORMATION Scanner Connector End USB Connector End 10-Pin RJ45 Male Type A Locking Type A Pin Function MX009-2MA7x and MX009-2MB7x and 1 Ground MX009-2MA8x or MX009-2MB8x 2 TXD 3 RXD x = C (coiled) or S (Straight) cable 4 RTS Pin Function 5 CTS 1 Vbus 6 DTR/LP 2 D- 7 Reserved 3 D+ 8 LP Data 4 Ground 9 +5 VDC From Transformer 10 SHD/GND ...

  • Metrologic Instruments MX009 - page 26

    22 L IMITED W ARRANTY The MX009 USB converter cables are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility and at its Suzhou, China facility. The MX009 USB converter cables have a two (2) year limited warranty from the date of manufacture. Metrol ogic warrants and represent s that all MX009 USB converter cables are free of al ...

  • Metrologic Instruments MX009 - page 27

    23 N OTICES TESTED TO COMPLY WITH FCC STANDARDS FOR HOME OR OFFICE USE Notice This device complies with Part 15 of the F CC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operat ...

  • Metrologic Instruments MX009 - page 28

    24 N OTICES D ECLARATION OF C ONFORMITY According to 47 CFR, Part 2 and 15 for Class B Personal Computers and Peripherals; and/or CPU Boards and Power Supplies used with Class B Personal Computers: We: Metrologic Instruments, Inc. Located at: 90 Coles Road Blackwood, NJ 08012 Telephone: 856-228-8100 Declare under sole responsibility that the produc ...

  • Metrologic Instruments MX009 - page 29

    25 A DDITIONAL B AR C ODES Some Metrologic scanners require alternate configuration steps than the steps found on pages 8 - 18. If your scanner was manufactured before May 2002 or does not accept the standard configuration sequences, you may need to use one of the alternate configuration methods listed on the following pages. Contact a Metrologic c ...

  • Metrologic Instruments MX009 - page 30

    26 A DDITIONAL B AR C ODES 7. *Enable LF Suffix ³ 116612 8. Scan the appropriate bar code below to set USB Keyboard Emulation to the country keyboard required. B ELGIUM ³ 80360650 U NITED K INGDOM ³ 80360660 F RANCE ³ 80360670 G ERMAN ³ 80360680 I TALIAN ³ 80360690 S PANISH ³ 80360700 ...

  • Metrologic Instruments MX009 - page 31

    27 A DDITIONAL B AR C ODES U NITED S TATES ³ 80360710 R ESERVED ³ 80360720 S WISS ³ 80360730 S WEDISH /F INNISH ³ 80360740 J APANESE ³ 80360750 R ESERVED ³ 80360760 9. E NTER /E XIT C ONFIGURATION M ODE ³ 999999 ...

  • Metrologic Instruments MX009 - page 32

    28 A DDITIONAL B AR C ODES Alternate Configuration for USB Serial Emulation (MX009-2xx8x) PowerLink Compatible Scanners 1. E NTER /E XIT C ONFIGURATION M ODE ³ 999999 2. R ECALL D EFAULTS ³ 999998 3. ENABLE RS-232 MODE ³ 415554 4. E NABLE XON/XOFF H ANDSHAKING ³ 115914 5. ENABLE ACK/NAK ³ 115913 Continued on next page. ...

  • Metrologic Instruments MX009 - page 33

    29 A DDITIONAL B AR C ODES 6. *E NABLE LF S UFFIX ³ 116612 7. E NTER /E XIT C ONFIGURATION M ODE ³ 999999 ...

  • Metrologic Instruments MX009 - page 34

    30 C ONTACT I NFORMATION AND O FFICE L OCATIONS C ORPORATE H EADQUARTERS N ORTH A MERICA E UROPEAN , M IDDLE E AST & A FRICAN H EADQUARTERS USA, New Jersey Germany, Munich Metrologic Instruments, Inc. Metrologic Instruments GmbH Tel: 1-800-ID-METRO Fax: 856-228-6673 Tel: 49-89-89019-0 Fax: 49-89-89019-200 Email: info@metrologic.com Email: info@ ...

  • Metrologic Instruments MX009 - page 35

    ...

  • Metrologic Instruments MX009 - page 36

    June 2005 Printed in the USA 00 - 02574 D ...

メーカー Metrologic Instruments カテゴリー Computer Drive

Metrologic Instruments MX009のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- MX009の取扱説明書
- Metrologic Instrumentsの製品カード
- パンフレット
- またはMetrologic Instruments MX009の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Metrologic Instruments MX009の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Metrologic Instruments MX009の取り付け説明書、サービスマニュアル、簡易説明書、またはMetrologic Instruments MX009のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Metrologic Instruments MX009の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Metrologic Instruments MX009デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMetrologic Instruments MX009を使用するのを助ける技術的文書のことです。説明書は通常、全てのMetrologic Instruments MX009ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Metrologic Instrumentsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Metrologic Instruments MX009の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMetrologic Instruments MX009の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Metrologic Instruments MX009に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Metrologic Instruments MX009デバイスの基本機能を使うにあたってのヒント。 Metrologic Instruments MX009のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Metrologic Instruments MX009に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMetrologic Instruments MX009のメーカー/サービスへの連絡先に関する情報。

Metrologic Instruments MX009についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMetrologic Instruments MX009の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMetrologic Instruments MX009で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)