Exergen TAT-5000の取扱説明書

32ページ 0.55 mb
ダウンロード

ページに移動 of 32

Summary
  • Exergen TAT-5000 - page 1

    EXERGEN T emporal Scanner TM A kinder, gentler way to take temperature Model T A T -5000 Reference Manual 1. Greenes DS, Fleisher , Accuracy of a noninvasive temporal artery ther- mometer for use in infants, Arch Pediatr Med 2001 Mar; 155(3):376-381 1 818528r5:818528r5.qxd 4/24/2008 11:04 AM Page 1 ...

  • Exergen TAT-5000 - page 2

    818528r5:818528r5.qxd 4/24/2008 11:04 AM Page 2 ...

  • Exergen TAT-5000 - page 3

    Import ant Safety Instructions READ ALL INSTRUCTIONS BEFORE USING When using the product, especially when children are present, basic safety precautions should always be followed, including the following:  If you have any additional questions regarding use or care of the thermometer , please see ww w .exergen.com or call customer service at 617- ...

  • Exergen TAT-5000 - page 4

    Product Map Product Map Probe Lens Probe Cone ON Button Automatic turn-off in 30 seconds (when measuring in body temperature range, otherwise 5 seconds) Battery Comp artment 9-volt battery Battery Comp artment Door 9-V olt Battery Comp artment Door Screw LED Display Screen 2 F/C Switch 818528r5:818528r5.qxd 4/24/2008 11:04 AM Page 4 ...

  • Exergen TAT-5000 - page 5

    Introduction to T emporal Artery Thermometry The Method T emporal artery thermometry (T A T) is a completely new method of temperature assessment, using infrared technology to detect the heat naturally emitting from the skin surface. In addition, and of key importance, the method incorporates a patented arterial heat balance system to automatically ...

  • Exergen TAT-5000 - page 6

    T able of Content s T able of Content s Page(s) Important Safety Instructions 1 Product Map 2 Introduction to T emporal Artery Thermometry 3 Familiarize Y ourself with the T emporal Scanner 5-6 Using the Instrument 7 Using the Instrument on a New Mother 8 Using the Instrument on an Infant 9 Frequently Asked Questions 10-13 Disposable Cover Options ...

  • Exergen TAT-5000 - page 7

    Familiarize Y ourself with the Instrument Before Using, Familiarize Y ourself with the Instrument • T o Scan: Depress the red button. The instrument will continually scan for the highest temperature (peak) as long as the button is depressed. • Clicking: Each fast click indicates a rise to a higher temperature, similar to a radar detector . Slow ...

  • Exergen TAT-5000 - page 8

    Familiarize Y ourself with the Instrument 1 2 3 4 Practice Holding Y our T emporal Scanner The T emporal Scanner is ergonomically designed specifically for its application. It’s best to hold the instrument with your thumb on the red button, much like you would hold a remote control. Along with allowing you to easily read the temperature display , ...

  • Exergen TAT-5000 - page 9

    Basics of Using the T emporal Scanner Measure only the exposed side. Brush hair aside if covering the T A area. 1. With probe flush on the center of forehead, depress red button, keep depressed… 2. Slowly slide probe midline across forehead to the hair line, not down side of face . Brush hair away if covering ear . 3. Lif t probe from forehead an ...

  • Exergen TAT-5000 - page 10

    Using the T emporal Scanner on a New Mother • Measure exposed skin • Keep the red button depressed throughout measurement (Brush bangs aside if present) 1. With probe flush on center of forehead, depress red button. 2. Slowly slide probe across the forehead into the hair line. 3. Lift probe from forehead. (Brush hair away if covering ear) 4. T ...

  • Exergen TAT-5000 - page 11

    Questions? Please call us at 800-422-3006 Using the T emporal Scanner on an Infant T emping Baby in Bassinette, Open Crib, or with Mom • Instrument should be in same temperature environment as the baby for approximately 20 minutes. • Measurement site must be exposed. • One measurement, preferably at the T A, is all that is required. Preferred ...

  • Exergen TAT-5000 - page 12

    Frequently Asked Questions Frequently Asked Questions What is the T emporal Scanner ? The T emporal Scanner is an infrared thermometer designed for accurate, completely non-invasive temperature assessment by scanning the temporal artery (T A). It is breakthrough technology . How does it work? T emperature is measured by gently stroking the T empora ...

  • Exergen TAT-5000 - page 13

    Frequently Asked Questions Why not use only the area behind the ear lobe? Since the arterial branch is deeper behind the ear lobe than at the temple, under normal conditions it is less accurate because of its variability . But under diaphoretic conditions, the blood flow behind the ear lobe is as high as at the T A, making it as accurate as the T A ...

  • Exergen TAT-5000 - page 14

    Frequently Asked Questions False low readings: • Multiple readings can cool the skin, so if you take another measurement immediately , expect a slightly lower reading. • Slide the thermometer straight across the forehead, not down the side of the face where the T A could be embedded under cartilage or fat. • Keep the probe flush on the skin, ...

  • Exergen TAT-5000 - page 15

    Frequently Asked Questions • T A T -5000 can be used with either disposable caps or full sheath. Can be used without disposables if terminally cleaned between patient s. • Can be cleaned with any hospital approved disinfectant, alcohol, and even bleach solutions. Use only alcohol solution for sensor lens . • ”bAtt” on the display indicate ...

  • Exergen TAT-5000 - page 16

    Guidelines for Patient T emperature Assessment Guidelines for Patient T emperature Assessment Comp aring with Other Methods of Thermometry: Expect the Differences Unless you are using P A catheters or Exergen aural thermometers with AHB for temperature assessment, expect to see differences comp ared to your current ther- mometers. Arterial temperat ...

  • Exergen TAT-5000 - page 17

    Guidelines for Patient T emperature Assessment Guidelines for Patient T emperature Assessment 1. Fever Definition: Clinically , fever is defined as a BT =1.8°F (1°C) above the mean standard deviation at the site of recording. 2 A single oral temperature of 101°F (38.3°C ) in the absence of obvious environmental causes is usually considered feve ...

  • Exergen TAT-5000 - page 18

    Determining a Fever Threshold Determining a Fever Threshold for T emporal Artery Thermometry Threshold Defining Fever • A threshold for defining fever is the temperature level above which false positives due to normal variations in temperature, including range of normal mean + circadian effect s + other effect s (metabolic, ovulation, etc.) are u ...

  • Exergen TAT-5000 - page 19

    Body Sites for T emperature Assessment Body Sites for T emperature Assessment An Overview of T emperature Measuring Sites Oral T emperature Oral temperature measurement is by far the most common clinical method in use today , and is responsible for masking the greatest number of fevers. Oral temperature can be mislead- ingly lowered by patient acti ...

  • Exergen TAT-5000 - page 20

    Body Sites for T emperature Assessment Under certain conditions, rect al temperature is even contraindicated; for example, severe arterial insufficiency in one or both legs might be associated with falsely low readings, or in conditions affecting peripheral blood flow such as cardiogenic shock. More common con- traindications include neutropenia, s ...

  • Exergen TAT-5000 - page 21

    Reproducibility of Readings Reproducibility in T emperature Measurement Multiple temperature readings in the same area, mouth, rectum, axilla, ear or temporal artery , make for variability with each separate measurement. This can be confusing for clinicians, since they expect the same number with each measurement. The non-reproducibility of the rea ...

  • Exergen TAT-5000 - page 22

    Forgotten Physiology Y our T emperature Normal T emperature Normal human temperature is around 98.6 degrees. But did you know that only 8% of the people in the world have a nor- mal temperature of exactly 98.6? A temperature that is normal for you may even be a whole degree or so above or below "normal." It is good to know what is normal ...

  • Exergen TAT-5000 - page 23

    Forgotten Physiology Perspiration The T emporal Scanner relies on the skin over the temporal artery to help provide an accu- rate body temperature. In fact, it is measuring the inside by measuring the outside. Y our skin is a sensor , controlling body temperature in two ways: radiation and evaporation. Since most of us don’t think about our skin ...

  • Exergen TAT-5000 - page 24

    For Kids Only Did you know you always have a tempera- ture? Bet you thought you only had a tem- perature when you were sick. Absolutely everything has a temperature, even icicles. Brrrrrr! When you don't feel well, your mom or a nurse might say "let's see if you have a temperature," but what they really mean is "let’s see ...

  • Exergen TAT-5000 - page 25

    Care and Maintenance Care and Maintenance • Battery: A standard alkaline 9V battery provides approximately 15,000 readings. ** T o replace, loosen the single screw at the bottom of the instrument and remove the battery cover . Disconnect the old battery and replace with a new one in the same location. Replace the cover , and tighten the screw . U ...

  • Exergen TAT-5000 - page 26

    Care and Maintenance Instructions for Fahrenheit or Celsius Conversion The T emporal Scanner can be used in either °F or °C. T o convert from one scale to the other , the only tool necessary is a p aper clip or the tip of a small screwdriver . For °F/°C Conversion: • Loosen single screw on bottom of case and remove battery cover . • Lift ba ...

  • Exergen TAT-5000 - page 27

    Care and Maintenance *Automatically applied when temperature is within normal body temperature range, otherwise reads surface temperature. Calibration V erification Procedure All Exergen infrared thermometers are designed to permanently maintain their accuracy and normally recali- bration is not required unless the thermometer has been physically d ...

  • Exergen TAT-5000 - page 28

    Care and Maintenance Using the Port able Blackbody 1. T urn on the verifier device, using either a 9-volt battery or the power supply . Make sure the red LED is illuminated. 2. Allow device ~5 minutes for warm-up and stabilization time. 3. Allow certified master or the two reference thermometers and the instrument to be tested to acclimate in the s ...

  • Exergen TAT-5000 - page 29

    Care and Maintenance • Accuracy Limits: Comp arison between the reference instrument(s) and the instrument being verified should be within ±0.4 º F (0.2 º C) for accept able limits. If not, repeat the process. In the event they still differ by more than the accept able limits, call Exergen for rep air or replacement of the failed instrument. V ...

  • Exergen TAT-5000 - page 30

    818528r5:818528r5.qxd 4/24/2008 11:05 AM Page 30 ...

  • Exergen TAT-5000 - page 31

    818528r5:818528r5.qxd 4/24/2008 11:05 AM Page 31 ...

  • Exergen TAT-5000 - page 32

    EXERGEN S traight From the Heart o EXERGEN CORPORA TION • 400 PLEASANT STREET • W A TERTOWN, MA 02472 • PH 617.923.9900 www .exergen.com p/n 818528 r5 818528r5:818528r5.qxd 4/24/2008 11:05 AM Page 32 ...

メーカー Exergen カテゴリー Thermometer

Exergen TAT-5000のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- TAT-5000の取扱説明書
- Exergenの製品カード
- パンフレット
- またはExergen TAT-5000の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Exergen TAT-5000の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Exergen TAT-5000の取り付け説明書、サービスマニュアル、簡易説明書、またはExergen TAT-5000のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Exergen TAT-5000の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Exergen TAT-5000デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがExergen TAT-5000を使用するのを助ける技術的文書のことです。説明書は通常、全てのExergen TAT-5000ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Exergenの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Exergen TAT-5000の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははExergen TAT-5000の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Exergen TAT-5000に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Exergen TAT-5000デバイスの基本機能を使うにあたってのヒント。 Exergen TAT-5000のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Exergen TAT-5000に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるExergen TAT-5000のメーカー/サービスへの連絡先に関する情報。

Exergen TAT-5000についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもExergen TAT-5000の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがExergen TAT-5000で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)