    UNITED STATES STOVE COMPANY 227 Industrial Park Road P.O.Box 151 South Pittsburg, TN 37380 (423) 837-2100 Model 1537Q SOLID FUEL W ARM AIR FURNA CE Owners Manual C O M P A N Y U N I T E D S T A T E S S T O V E C S S U WARNOCK HERSEY R *FOR P ARALLEL INST ALLA TION WITH AN EXISTING FORCED AIR, GAS OR OIL FIRED FURNA CE (U .S. ONL Y) *FOR INST ALLA T ...

  • United States Stove 1537Q - page 2

    CONGRA TULA TIONS! You've purchased one of America's Finest Wood and Coal Burning Furnaces. By heating with wood and coal you're helping to CONSERVE AMERICA'S ENERGY! Wood is our Renewable Energy Resource. Please do your part to preserve our wood supply. Plant at least one tree each year. Future generations will thank you. NOTE: ...

  • United States Stove 1537Q - page 3

    Caution Labels Your Furnace has the following labels. Read and obey all labels. DANGER: RISK OF FIRE OR EXPLOSION. DO NOT burn garbage, gasoline, drain oil, or other flammable liquids. WARNING: FIRE HAZARD. DO NOT operate with fire draft exceeding .06 inches W.C. DO NOT operate with fuel loading or ash removal doors open. DO NOT store fuel or other ...

  • United States Stove 1537Q - page 4

    rules for safe installation and operation Read these rules and the instructions carefully. Failure to follow them will cause a hazard that could result in death, serious bodily injury, and/or property damage. Check your local codes. This installation must comply with their rulings. Do not install this furnace in a mobile home or trailer. Always con ...

  • United States Stove 1537Q - page 5

    Your Supplemental Furnace is designed to be a supplemental or central heating source for your home. This solid fuel furnace may be installed in conjunction with a properly operating central furnace that is listed or certified in accordance with nationally recognized safety standards and equipped with the required controls and other safety features ...

  • United States Stove 1537Q - page 6

    24-1/16 40-11/16 32-1/4 3-1/2 9" 33-7/8 43-7/8 Model 1537Q Dimensions FIG. 1 6 ...

  • United States Stove 1537Q - page 7

    12" 9" 48" 18" CENTRAL FURNACE 6" CHIMNEY 18" 18" 6" SOLID DAMPER 6" BAROMETRIC DRAFT REGULATOR (OPTIONAL) NON-COMBUSTIBLE FLOOR The furnace should be located in the same room as the central system and as close as possible, but no closer than 9". There should be no wall between the furnace and the w ...

  • United States Stove 1537Q - page 8

    chimney connection MASONRY CHIMNEY Before using an existing masonry chimney, clean the chimney and inspect the flue liner to be sure it is safe to use. Make repairs before attaching the furnace. See Page 4, item 5. Look at Fig. 4. The connector pipe and fittings you will need to connect directly to a masonry chimney are shown. The chimney connectio ...

  • United States Stove 1537Q - page 9

    The crimped end of the chimney con- nector fits inside the furnace flue collar. Install additional chimney connector and elbow with the CRIMPED END TOWARD THE FURNACE. This will allow any con- densation in the flue to run back into the furnace. Use 6" dia. (minimum 24 gauge) black chimney connector. Slope any horizontal pipe upward toward the ...

  • United States Stove 1537Q - page 10

    Your furnace requires the following items to be assembled or installed by the service person: Feed Door Handle Feed Door Latch Smoke Curtain Blowers and Blower Controls Electrical Connections Remove all parts from inside the furnace and inspect for damage, including the firebrick as some breakage could occur during ship- ment. Assemble the feed doo ...

  • United States Stove 1537Q - page 11

    11 Honeywell FAN/LIMIT CONTROL 4" ELECTRICAL JUNCTION BOX BLOWER ASSEMBLY GASKET CLIP NUTS (DO NOT USE CLIP NUT ON UPPER CENTER HOLE) Blower & Component Assemb l y - FIG. 11 ...

  • United States Stove 1537Q - page 12

    Model 1537Q Wiring Diagram - FIG. 12 12 BLOWER LIMIT CONTROL LOAD FAN LINE LOAD LIMIT LINE BLACK BLACK WHITE WHITE RED JUNCTION BOX GROUND BLACK BLACK RED 110 VAC 60 HZ WHITE BLACK FORCED DRAFT BLOWER BLUE BLACK WHITE WHITE BLACK BLOWER BLOWER BLACK WHITE FAN CONTROL CENTER (FRONT) BLUE BLACK BLACK 1 2 3 4 5 6 COIL COIL BROWN BLUE BLACK R G C WY FA ...

  • United States Stove 1537Q - page 13

    13 Installation Please see all methods of Installation in Appendix at the rear of this booklet. This is a furnace, not a free standing stove. You must direct heated air from 8" outlets away from the furnace, or it will not function properly. 1. This installation must be done by a qualified heating equipment installer. 2. The installation is to ...

  • United States Stove 1537Q - page 14

    Power Failure Instructions: Operation after loss of power Remove filter if provided. Do not expect to keep home at normal temperatures. Do not load fuel abov e bottom of feed door . Set ash pan spin draft maximum one turn open. 1 2 3 4 2" MIN. AIR SPACE REQUIRED BY CODE 18" MIN. CENTRAL FURNACE (U.S. ONLY) FIG. 13 14 ...

  • United States Stove 1537Q - page 15

    COLD AIR DUCT 6" PIPE DAMPER OPTIONAL 11 RPT 90 ELBOW FURNACE PIPE CONNECTOR Central Installation (U. S. & Canada) FIG. 14 15 ...

  • United States Stove 1537Q - page 16

    COLD AIR DUCT 6" PIPE DAMPER 90 ELBOW FURNACE PIPE CONNECTOR EXISTING GAS/OIL/ELECTRIC FURNACE 8" PIPE Add-On Installation (U. S. Only) FIG. 14-1 16 ...

  • United States Stove 1537Q - page 17

    Series Installation Wiring Diagram - FIG. 15 TO GAS/OIL/ELECTRIC TRANSFORMER AND COMBUSTION FAN OF SOLID FUEL UNIT H N POWER SUPPLY FURNACE BLOWER MOTOR FAN LIMIT COMBINATION CONTROL GAS/OIL/ELECTRIC POWER SUPPLY JUNCTION BOX JUMPER IN CAUTION! DO NOT CONNECT PLENUM FAN CONTROL SWITCH ACROSS FURNACE LIMIT CONTROL. 17 ...

  • United States Stove 1537Q - page 18

    operating instructions 18 Your Clayton Furnace is capable of burning Wood or Coal. WOOD BURNING: (1)use Hardwood, 18" to 26", split and air dried (seasoned) for six months. (2) set thermostat to "HIGH" before opening feed door. (3) add wood to a convenient level. BURNING COAL: Clayton Furnaces are capable of burning Bituminous c ...

  • United States Stove 1537Q - page 19

    Add a thin layer of coal (preferably smaller chunks) to the wood fire, being careful not to disturb it too much or cut off the draft. Then, add a second heavier layer after the coal is ignited and burning well. If necessary, add a third layer to bring the coal up to the top of the front liner (not above!). Be sure to close the ash door. Before addi ...

  • United States Stove 1537Q - page 20

    20 service hints Do not expect a furnace to draw. It is the chimney that creates the draft. Smoke spillage into the house or exces- sive build-up of water or creosote in the chimney is not functioning properly. Correct the problem before using furnace. Possible causes are: The connector pipe may be pushed into the chimney too far, stopping the draf ...

  • United States Stove 1537Q - page 21

    KEY PART NO. DESCRIPTION QTY. 1 80130 Fan Control Center 1 2 80243A Forced Draft Blower 1 3 80129 Wall Thermostat 1 4 83250 Kep Nut (1/4-20) 4 5 83339 Hex Bolt (1/4-20 x 3/4) (BL,OX) 4 6 68618 Blower Mounting Plate 1 7 68231 Fan Control Cord Assembly 2 N/S 80006 Wire Nut 73B 4 21 11DIK - DRAFT INDUCED KIT N/S = NOT SHOWN 1 2 3 4 5 6 7 7 ...

  • United States Stove 1537Q - page 22

    Model 1537Q - Parts 22 ...

  • United States Stove 1537Q - page 23

    23 KEY PART NO. DESCRIPTION QTY. 1 69092 Fi rebox Weldment 1 2 23398 Baffle 1 3 40246 Flue Collar Casting 1 4 88032 Flue Collar Gasket 1 N/ S 83227 Bolt (1/4-20 x 1 MS, SL) 6 N/S 83250 Nut (Kep, 1/4-20) 6 5 69093 Cabinet Bottom Assembly 1 6 40258 Back Liner 1 7 40256 Shaker Frame 2 8 40257 Shaker Grate 2 9 89066 Firebrick 12 10 40269 Front Liner 1 ...

  • United States Stove 1537Q - page 24

    COLD AIR RETURN FILTER BOX SOLID FUEL FURNACE EXISTING FURNACE WARM AIR TO EXISTING DUCT WORK INSTALLATION A APPENDIX 24 ...

  • United States Stove 1537Q - page 25

    COLD AIR RETURN FILTER BOX SOLID FUEL FURNACE EXISTING FURNACE WARM AIR TO EXISTING DUCT WORK INSTALLATION B PLENUM COLLECTOR BOX 25 ...

  • United States Stove 1537Q - page 26

    COLD AIR RETURN FILTER BOX SOLID FUEL FURNACE EXISTING FURNACE WARM AIR TO EXISTING DUCT WORK INSTALLATION C PLENUM ELBOW PLENUM TOP (OPTIONAL) 26 ...

  • United States Stove 1537Q - page 27

    2" MINIMUM CLEARANCE DUCT WORK 11 PCS (OPTIONAL PLENUM FAN CONTROL LOCATION) FURNACE PLENUM EXISTING FURNACE ANTI-BACKDRAFT FLAPPER SOLID FUEL FURNACE COLD AIR RETURN INSTALLATION D 2" MINIMUM CLEARANCE DUCT WORK FURNACE PLENUM EXISTING FURNACE SOLID FUEL FURNACE COLD AIR RETURN INSTALLATION E BAFFLE (U. S. ONLY) (U. S. ONLY) 27 ...

  • United States Stove 1537Q - page 28

    2" MINIMUM CLEARANCE DUCT WORK FURNACE PLENUM EXISTING FURNACE SOLID FUEL FURNACE COLD AIR RETURN INSTALLATION F 2" MINIMUM CLEARANCE DUCT WORK SOLID FUEL FURNACE INSTALLATION G COLD AIR RETURN TO FILTER BOX CENTRAL FURNACE INSTALLATION 28 ...

  • United States Stove 1537Q - page 29

    2" MINIMUM CLEARANCE EXISTING OIL, ELECTRIC OR GAS FURNACE SOLID FUEL FURNACE INSTALLATION H EXISTING OIL, ELECTRIC OR GAS FURNACE SOLID FUEL FURNACE (TOP VIEW) (FRONT VIEW) 29 ...

  • United States Stove 1537Q - page 30

    List of Problems Possible Cause Solutions 1. Smoking when feed door is open. 2. Furnace does not heat. 3. Blower does not run. 4. No air from registers - fan running. 5. Air from registers is not hot. 6. Blower runs too long. 7. Blower does not run long enough. 8. Smoke and/or odor from registers when furnace is used for first time. 9. Creosote bui ...

  • United States Stove 1537Q - page 31

    31 Notes ...

  • United States Stove 1537Q - page 32

    THIS MANU AL WILL HELP Y OU OBT AIN EFFICIENT , DEPEND ABLE SER VICE FR OM Y OUR JENSEN FURNA CE, AND ENABLE Y OU T O ORDER REP AIR P AR TS COR- RECTL Y . KEEP THIS MANU AL IN A SAFE PLA CE FOR FUTURE REFERENCE. WHEN WRITING, AL W A YS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLA TE A TT A CHED T O THE HEA TER. WHEN ORDERING REP AIR P ART S, ...

メーカー United States Stove カテゴリー Furnace

United States Stove 1537Qのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 1537Qの取扱説明書
- United States Stoveの製品カード
- パンフレット
- またはUnited States Stove 1537Qの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、United States Stove 1537Qの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、United States Stove 1537Qの取り付け説明書、サービスマニュアル、簡易説明書、またはUnited States Stove 1537Qのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、United States Stove 1537Qの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

United States Stove 1537Qデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがUnited States Stove 1537Qを使用するのを助ける技術的文書のことです。説明書は通常、全てのUnited States Stove 1537Qユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

United States Stoveの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. United States Stove 1537Qの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははUnited States Stove 1537Qの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。United States Stove 1537Qに関してこのドキュメントで見つけることができる全てのヒントの目次
3. United States Stove 1537Qデバイスの基本機能を使うにあたってのヒント。 United States Stove 1537Qのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。United States Stove 1537Qに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるUnited States Stove 1537Qのメーカー/サービスへの連絡先に関する情報。

United States Stove 1537Qについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもUnited States Stove 1537Qの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがUnited States Stove 1537Qで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)