Sea-Fire FM200 - page 1
FM200 ® MODEL FT FIRE EXTINGUISHERS INST ALLA TION INSTRUCTIONS OWNER’S MANUAL THIS MANUAL IS AN INTEGRAL P AR T OF THE SYSTEM AND AS SUCH, THE EXTINGUISHER MUST BE INST ALLED AND MAINT AINED ACCORDINGL Y . READ AND COMPL Y WITH THESE INSTRUCTIONS, W ARNINGS AND LIMIT A TIONS BEFORE INST ALLING. SUIT ABLE FOR USE FT MODELS: 32°F – 130°F ( 0? ...
-
Sea-Fire FM200 - page 2
W ARNING CONCENTRA TED AGENT AND BY-PRODUCT OF APPLICA TION TO FIRE ARE T OXIC. A VOID BREA THING OF FUMES OR PROLONGED EXPOSURE. ACCIDENT AL DIS- CHARGE MA Y OCCUR DURING HANDLING OR INST ALLA TION OF THIS DEVICE, READ AND COMPL Y WITH INSTRUCTIONS, WARNINGS, AND LIMIT A TIONS CONT AINED IN THIS MANUAL. DO NOT LIFT , CARRY , OR HANDLE BY V AL VE. ...
-
Sea-Fire FM200 - page 3
REMINDER: Sea-Fire systems shall be considered as supplementary to the number of portable fire extinguishers required on-board and are designed and intended for enclosed unoccupied compartment installations that are not subject to direct weather or water . SYSTEM OPERA TIONS Sea-Fire units described in this manual are automatically actuated by a he ...
-
Sea-Fire FM200 - page 4
OTHER APPLICA TIONS • Engine Compartments (maximum 150 cubic feet) • Bow Thrusters • Small Generator Set Enclosures • Consoles • Electrical Enclosures • Flammable Liquid Storage Areas • Pump Enclosures • Alternative Fuel Storage Areas In case of a fire and system discharged, the electrical supply to the motor must be discon- nected. ...
-
Sea-Fire FM200 - page 5
Figure 5 Step 8 Secure the detection tubing to the bulkhead by using the clips and screws supplied. Nylon wire ties may be used in lieu of the clips and screws. Note: Do not exceed a bend radius of 6 inches during the routing of the tube. W ARNING WHEN INST ALLING THE DETECTION TUBING, DO NOT KINK THE TUBING AND DO NOT EXCEED THE MINIMUM BEND RADIU ...
-
Sea-Fire FM200 - page 6
Figure 6 THE FT EXTINGUISHER INST ALLA TION IS COMPLETE. INDICA TOR LIGHT OPERA TION All Sea-Fire extinguishers approved for marine applications are packaged with an indicator light and escutcheon. ‘‘The U.S. Coast Guard approval requires an indicator light if this unit is installed for the protection of a boat’s engine compartment.” The in ...
-
Sea-Fire FM200 - page 7
ELECTRICAL SWITCH INDICA TOR LIGHT GROUND IN-LINE FUSE IGNITION IGNITION SWITCH ST ARTER BA TTERY Figure 9 Figure 3 WHILE MAKING ELECTRICAL CONNECTION CAN RESUL T IN INJUR Y FROM FIRE OR ELECTRICAL BURNS. The indicator light is rated for 12 VDC (contact factory for other voltages). Wire in accor- dance with the American Boating and Y acht Council s ...
-
Sea-Fire FM200 - page 8
Before operating the protected vessel, visually inspect pressure gauge for compliance and ensure the supervisory (indicator) light is lit. If gauge reads low in pressure, and or the indica- tor light is extinguished, remove, and replace the system immediately . Never paint or obstruct the detection tube, as this will adversely affect its operating ...
-
Sea-Fire FM200 - page 9
CONDITIONS All Sea-Fire products are tested after manufacture and shipped in perfect working order . Damage noted upon receipt of shipment should be addressed as a shipping claim, the filing of which is the sole responsibility of the consignee for which the total compensatory award will be limited to that appropriated by the carrier . Insured freig ...
-
Sea-Fire FM200 - page 10
ALL FT (STINGER) MODELS ARE APPROVED FOR VERTICAL MOUNTING ONL Y . INTENDED OPERA TING TEMPERA TURE RANGE : 32°F –130°F (0°C – 54°C ) ST ANDARD EQUIPMENT LIST SUPPLIED WITH EACH SYSTEM 1. ONE TUBING KIT , P ART # 130-121 – 10 FOOT TUBE OR 130-122 – 15 FOOT TUBE. 2. ONE BRACKET ASSEMBL Y — Model # Bracket Part # FT-25 122-010 FT-50 122 ...
-
Sea-Fire FM200 - page 11
FG/FD/FT/MD/R/C-MODEL Fire Extinguisher MSDS No. SF002 MA TERIAL SAFETY DA T A SHEET Section 1 — Company and Chemical Identification MET ALCRAFT/SEA-FIRE MARINE EMERGENCY PHONE: 1-800-535-5053 9331-A PHILADELPHIA ROAD PHONE: 1-800-445-7680 BAL TIMORE, MARYLAND 21237DA TE: NOVEMBER 10, 2005 http://www .sea-fire.com PRODUCT NAME: Fire Extinguisher ...
-
Sea-Fire FM200 - page 12
Section 7 — Handling and Storage Handle, transport and store carefully and securely to avoid accidental knocking over or other severe physical impacts. Do not expose to direct heat sources. Do not over-pressurize. Section 8 — Exposure Controls/Personal Protection Respiratory: None Protective Gloves: Leather gloves are recommended when handling ...
-
Sea-Fire FM200 - page 13
Section 15 — Regulatory Information U.S. Federal Regulations: The components of this product are either on the TSCA Inventory or exempt (i.e. impurities, a polymer complying with the exemption rule at 40 CFR 723.250) from the Inventory . State Regulations: None Known Section 16 — Other Information NFP A Codes: Health: 1 Flammability: 0 Reactivi ...
-
Sea-Fire FM200 - page 14
SEA-FIRE MARINE SEA-FIRE EUROPE L TD Division of Metalcraft Inc. Unit 7. io Centre. Stephenson Road 9331-A Philadelphia Road Fareham, Hampshire Baltimore, Maryland 21237 USA PO15 5RU, United Kingdom Website: www .sea-fire.com 14 ...
Sea-Fire FM200についてご質問がありますか?
次のフォームを使用してください
見つけた説明書を読んでもSea-Fire FM200の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがSea-Fire FM200で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。