    LDLINE CON TR OLS INC . G www .goldlinecontr ols.com 888-921-7665 Aqua Logic Aqua Logic Aqua Logic Aqua Logic Aqua Logic Automation and Chlorination Inst allation Manual for models AQ-LOGIC-PS-4 AQ-LOGIC-PS-8 ...

  • Raypak PS-4 PS-8 - page 2

    IMPORT ANT SAFETY INSTRUCTIONS When using this electrical equipment, basic safety precautions should always be followed, including the following: • READ AND FOLLOW ALL INSTRUCTIONS • ! W ARNING: Disconnect all AC power during installation. • ! W ARNING: W ater in excess of 100 degrees Fahrenheit may be hazardous to your health. • ! W ARNING ...

  • Raypak PS-4 PS-8 - page 3

    T able of Content s Introduction Before Y ou Begin................................................................... 1 Plumbing Requirements....................................................... 2 Electrical Requirements....................................................... 2 Installation S teps................................................... ...

  • Raypak PS-4 PS-8 - page 4

    Introduction Before Y ou Begin Before installing the Aqua Logic System -Determine that you have everything necessary to complete the installation -Find a suitable mounting location for both the control center and remote keypad -Plan and determine where components will be plumbed -Plan wire runs and wiring connections What’s Included Before attemp ...

  • Raypak PS-4 PS-8 - page 5

    Plumbing Requirement s The only special plumbing requirements for the Aqua Logic are the T urbo Cell and flow switch which are typically plumbed after the heater but before the pool/spa return valve. Refer to page 9 for detailed instructions. Electrical Requirement s Power must be shut off at the circuit breaker before performing any wiring. Be sur ...

  • Raypak PS-4 PS-8 - page 6

    ºC ºF Ti Calcuim Hardness Ci To t a l Alkalin ity Ai 53 60 66 76 84 94 103 12 16 19 24 29 34 39 .3 .4 .5 .6 .7 .8 .9 How to use: Measu re pool pH, tempe rature, calcium hard ness, and total alkalinity . Us e the chart above to determine T i, Ci,and Ai from your measure ments. Insert valu es of pH, T i, Ci and A i into the above equat ion. If S i ...

  • Raypak PS-4 PS-8 - page 7

    The pool’ s chemistry must be balanced BEFORE activating the Aqua Logic’ s sanitizing function. NOTE: If the pool does not have new water , add metal remover and non-copper based algaecide to the pool, per manufacturer ’ s instructions. This ensures a quick, troublefree transfer to the Aqua Logic system. Salt Salt Level Use the chart below to ...

  • Raypak PS-4 PS-8 - page 8

    Pool Sizing Formula T ype of Salt to Use It is important to use only sodium chloride (NaCl) salt that is greater than 99% pure. This is common food quality or water softener salt and is usually available at building supply stores in 40-80 lb. bags labeled coarse or fine “Solar Salt”. It is also acceptable to use water conditioning salt pellets, ...

  • Raypak PS-4 PS-8 - page 9

    2. Mounting the Equipment Aqua Logic Control Center The Aqua Logic is contained in a raintight enclosure that is suitable for outdoor mounting. The control must be mounted a minimum of 5 ft. (2 meters) horizontal distance from the pool/spa (or more, if local codes require). The Control Center is designed to mount vertically on a flat surface with t ...

  • Raypak PS-4 PS-8 - page 10

    3 . See “Electrical W iring” (page 17) for instructions on running the cable from the Aqua Logic main unit to the remote display/keypad. Optional Wireless Remote Display/Keyp ad The Aqua Logic W ireless Remote Display/Keypad (Goldline part number AQL-REMOTE-RF-PS-x) must be mounted indoors or in a weather protected area (rain should never hit t ...

  • Raypak PS-4 PS-8 - page 11

    3. Plumbing General Pool Equipment Refer to the following guidelines and the diagram below . 1. Spa should be at or above the level of the pool. For raised spas: Provide a means for the spa to overflow into the pool and install check valves in the spa return and the pool suction (see diagram) to prevent the spa draining while the pool/spa suction a ...

  • Raypak PS-4 PS-8 - page 12

    T urbo Cell The T urbo Cell (used for chlorine generation) should be plumbed AFTER the filter and heater . If installed on a pool/spa combination system, the cell should be plumbed BEFORE the pool/spa return valve in order to allow proper chlorination of both the pool and the spa. Refer to plumbing diagram below: The cell may be mounted vertically ...

  • Raypak PS-4 PS-8 - page 13

    4. Electrical Wiring The Aqua Logic Control Center requires both high and low voltage connections. Low voltage connections will be made to actuators, sensors, remote keypad, etc. High voltage connections will be made to pumps, lights, etc., as well as providing direct input power to the Control Center . Always: -Ensure that Power is disconnected pr ...

  • Raypak PS-4 PS-8 - page 14

    Grounding and Bonding Connect a ground wire from the primary electrical panel to the Aqua Logic ground bus bar . Also ground each piece of high voltage (120 or 240V AC) equipment that is connected to the Aqua Logic control relays or circuit breakers. The Aqua Logic should also be connected to the pool bonding system by an 8A WG (6A WG for Canada) w ...

  • Raypak PS-4 PS-8 - page 15

    High V olt age (120/240V) Pool Equipment All Aqua Logic relays are double pole (they make/break both “legs” of 240V circuits) and are rated at 3HP/30A at 240V (1½HP/30A at 120V). Refer to the diagram below for typical relay wiring: ! W ARNING: Do not use the Aqua Logic to control an automatic pool cover . Swim- mers may become entrapped undern ...

  • Raypak PS-4 PS-8 - page 16

    Low V olt age Wiring V alve Actuators The Aqua Logic can control up to four 24V automatic valve actuators. T wo of the valve outputs are dedicated to the pool/spa suction (V alve2) and return (V alve1) valves. V alve3 and V alve4 are for general purpose use (solar , water feature, in-floor cleaner , etc.). For installations with solar heating, Gold ...

  • Raypak PS-4 PS-8 - page 17

    Generic Heaters 1. W ire heater to 120/240V power source per the instructions in the heater manual. The Aqua Logic does NOT control the power going to the heater . 2. W ire the Aqua Logic dry contact heater output per the diagram below . Many internal parts of the heater can get very hot--see the heater manufacturer ’ s recommendations on the min ...

  • Raypak PS-4 PS-8 - page 18

    Hayward Heaters Refer to the instructions in the heater manual for “2-wire Remote Thermostat” operation under “Remote Control Connections” and the diagram on the following page: 1. Turn of f power to heater 2. W ire Aqua Logic to terminals 1 & 2 (see diagram) 3. Leave jumper attached to terminals 4 & 5 4. Move “BYP ASS” dipswitc ...

  • Raypak PS-4 PS-8 - page 19

    Raypak RP2100 Pool/Spa Heater 1. T urn power off to heater 2. Push the mode button to “spa” mode 3. Set the temperature to the maximum 4. Push the mode button to “OFF” 5. Lastly , plug the prewired connector in the P7 position on the board. ! IMPORT ANT : The heater will display “OFF” when it is being r emotely contr olled by the Aqua L ...

  • Raypak PS-4 PS-8 - page 20

    T emperature Sensors The Aqua Logic utilizes 10K ohm thermistor type sensors. T wo sensors (water temperature and air temperature) are included. If the Aqua Logic is being used to control a solar heating system, a third “solar” sensor will be required. The sensors are provided with a 12 ft. cable. If a longer cable is required, contact the Gold ...

  • Raypak PS-4 PS-8 - page 21

    I f multiple r emote display/keypads are installed: Never connect more than 2 wires to any terminal block. T wo remotes can be wired back to the Aqua Logic main unit or the second display/keypad (and third, if applicable) can be “daisy chained” with one display/keypad wired to the next. The maximum wire run from the Aqua Logic main unit to the ...

  • Raypak PS-4 PS-8 - page 22

    5. Configuration Setup After plumbing and wiring are complete, the Aqua Logic MUST BE CONFIGURED before attempting to operate. Configuration information is entered at the keypad and “tells” the Aqua Logic what equipment is connected and how each should be controlled. Accessing the Configuration Menu Configuring the Aqua Logic requires that you ...

  • Raypak PS-4 PS-8 - page 23

    Logic will turn on the filter pump to circulate the water . If “Pool and Spa” is selected in the Pool/Spa sub-menu (see page 21), the valves will also alternate between the pool and spa every 30 minutes and the filter pump will turn off while the valves are turning. The heater(s) and chlorinator will not operate if freeze protection is the only ...

  • Raypak PS-4 PS-8 - page 24

    21 Solar Con fig. + to view/ change So la r Disa bled Sol ar-Ext end Disa bled Solar Priority Disa bled Push t o acce ss solar options T oggl e betwe en Enabl ed an d Di sabled (def aul t) Solar T oggl e betwe en Enabl ed an d Di sabled (def aul t) Solar Ex tend T oggl e betwe en Enabl ed an d Di sabled (def aul t) Solar Ex tend Move to prev ious/n ...

  • Raypak PS-4 PS-8 - page 25

    22 is selected, then the pool/spa suction and return valve actuators should be connected to the Aqua Logic. Pressing the POOL/SP A button on the display/key pad will allow the home- owner to alternate between pool and spa operation. Spa Spillover When spa spillover is “Enabled”, the homeowner will be able to rotate through “Pool Only” (both ...

  • Raypak PS-4 PS-8 - page 26

    23 NOTE: The configuration parameters for all Aux outputs are same as shown below for Aux1. PS-4 models have two Aux outputs: Aux1 and Aux2. PS-8 models have six Aux outputs: Aux1 through Aux6. Aux 1 Co n fig . + to view/ change Aux1 F unction Ma nual On/Off Aux 1 F re ez e Disa bled Push to access Aux1 op tions Rotates bet ween opti ons Manual O n ...

  • Raypak PS-4 PS-8 - page 27

    24 Aux1 Interlock If “Enabled”, this feature will override the function (manual on/off, countdown timer , timeclock, selected above and turn the aux1 or aux2 relay off. This forced off condition occurs when: filter pump is off, first 3 minutes of filter pump operation (allows the pump to prime and get water flowing), when the pool/spa suction r ...

  • Raypak PS-4 PS-8 - page 28

    In-Floor Cleaner – the valve switches the water returning to the pool between the in-floor cleaner and the normal return jets which facilitate efficient surface skimming. The valve will operate the in-floor cleaner for the first half of each clock hour and then switch to the jets/ skimming for the last half of the hour . V alve3 Interlock If “E ...

  • Raypak PS-4 PS-8 - page 29

    26 6. System S t artup and Checkout Before S t artup Before starting the Aqua Logic for the first time, be sure that the following items have been completed: 1. Pool/spa chemicals are within the recommended levels according to the chart on page 3. 2. Pool/spa salt level is between 2700 – 3400 PPM. 3. Properly rated circuit breakers are installed ...

  • Raypak PS-4 PS-8 - page 30

    3. Once the heater is running, you can verify the “heater cooldown” feature (optional - see Configuration Menu/Heater Config.) is operating properly: • Press the “Filter” button once (for 2 speed pumps, this may require 2 pushes of the “Filter” button) • The heater should turn off (“Heater” LED off) and the “Filter” LED will ...

  • Raypak PS-4 PS-8 - page 31

    Limited W arranty—Pool Automation & Chlorination Product s 1/1/2004 This warranty statement is applicable to all pool automation and chlorination products manufactured by Goldline Controls, Inc. (Goldline) on or after January 1, 2004 . See the appropriate warranty statement for other Goldline products or for pool automation and chlorination p ...

  • Raypak PS-4 PS-8 - page 32

    North Kingstown, RI 02852 USA LDLINE CONTROLS I NC. G www .goldlinecontrols.com 888-921-7665 092042A Aqua Logic Programming Flow Chart denote s con ditiona l item s } } PS-4 only PS-4 only pool/spa config. lights confi g aux1 config aux2 config valve3 conf ig valve4 conf ig all timeclocks ( 7 or 2/5 day) t i m ef o r m a t ( 1 2o r 2 4h r ) units ( ...

メーカー Raypak カテゴリー Water System

Raypak PS-4 PS-8のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- PS-4 PS-8の取扱説明書
- Raypakの製品カード
- パンフレット
- またはRaypak PS-4 PS-8の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Raypak PS-4 PS-8の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Raypak PS-4 PS-8の取り付け説明書、サービスマニュアル、簡易説明書、またはRaypak PS-4 PS-8のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Raypak PS-4 PS-8の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Raypak PS-4 PS-8デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがRaypak PS-4 PS-8を使用するのを助ける技術的文書のことです。説明書は通常、全てのRaypak PS-4 PS-8ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Raypakの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Raypak PS-4 PS-8の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははRaypak PS-4 PS-8の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Raypak PS-4 PS-8に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Raypak PS-4 PS-8デバイスの基本機能を使うにあたってのヒント。 Raypak PS-4 PS-8のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Raypak PS-4 PS-8に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるRaypak PS-4 PS-8のメーカー/サービスへの連絡先に関する情報。

Raypak PS-4 PS-8についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもRaypak PS-4 PS-8の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがRaypak PS-4 PS-8で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)