  • Lincoln Electric RED-D-ARC FX450 - page 1

    RED-D-ARC FX450 IM10094 February, 2011 Red-D-Arc Spec-Built W elding Equipment This RED-D-ARC welder is built to RED-D-ARC Extreme Duty design specifications by Lincoln Electric. Safety Depends on Y ou This welder is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thoughtful opera ...

  • Lincoln Electric RED-D-ARC FX450 - page 2

    FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. ________________________________________________ ...

  • Lincoln Electric RED-D-ARC FX450 - page 3

    ii SAFETY ii ARC R A Y S can bur n. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistant material to protect your s ...

  • Lincoln Electric RED-D-ARC FX450 - page 4

    iii SAFETY iii FOR ELECTRIC ALL Y pow er ed equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations. 8.c. Ground the equipment in accordance with the U.S. Nat ...

  • Lincoln Electric RED-D-ARC FX450 - page 5

    iv SAFETY iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A LʼArc 1. Protegez-vous contre la secousse électrique: a. Les circuits à ...

  • Lincoln Electric RED-D-ARC FX450 - page 6

    v v Thank Y ou for selecting one of our QUALITY products. We want you to take pride in operating this product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay particular attention to the safet ...

  • Lincoln Electric RED-D-ARC FX450 - page 7

    vi vi T ABLE OF CONTENTS Page Installation .......................................................................................................Section A Technical Specifications ........................................................................................A-1 Welding Process, Physical Dimensions ........................................ ...

  • Lincoln Electric RED-D-ARC FX450 - page 8

    FX450 (RED-D-ARC) A-1 INST ALLA TION A-1 TECHNICAL SPECIFICA TIONS - FX450 RA TED OUTPUT POWER SOURCE-INPUT VOL T AGE AND CURRENT Model K3073-1 Duty Cycle 60% rating 100% rating Volts at Rated Amperes 36.5V 34V 28V 26V 38V 36V 36.5V 34V 36.5V 34V Amperes 450 400 450 400 450 400 450 400 450 400 Duty Cycle 60% 100% 60% 100% 60% 100% 60% 100% 60% 100% ...

  • Lincoln Electric RED-D-ARC FX450 - page 9

    A-2 INST ALLA TION FX450 (RED-D-ARC) A-2 PHYSICAL DIMENSIONS TEMPERA TURE RANGES HEIGHT 18.80in (478mm) MODEL K3073-1 WIDTH 14.14in (359mm) DEPTH 26.66in (677mm) WEIGHT 125lbs (56.6kg) * OPERATING TEMPERATURE RANGE Environmentally Hardened: 14°F to 131°F (-10°C to 55°C ** ) STORAGE TEMPERATURE RANGE Environmentally Hardened: -40°F to 185°F (- ...

  • Lincoln Electric RED-D-ARC FX450 - page 10

    A-3 INST ALLA TION A-3 SELECT SUIT ABLE LOCA TION LOCATION AND VENTILATION FOR COOLING Place the welder where clean cooling air can freely circulate in through the rear louvers and out through the case sides. Dirt, dust, or any foreign material that can be drawn into the welder should be kept at a mini- mum. Failure to observe these precautions can ...

  • Lincoln Electric RED-D-ARC FX450 - page 11

    A-4 INST ALLA TION A-4 INPUT FUSE AND SUPPL Y WIRE CONSIDERA TIONS Refer to Specification in this Installation Section for recommended fuse, wire sizes and type of the copper wires. Fuse the input circuit with the recommended super lag fuse or delay type breakers (also called "inverse time" or "thermal/magnetic" circuit breakers ...

  • Lincoln Electric RED-D-ARC FX450 - page 12

    A-5 INST ALLA TION A-5 FX450 (RED-D-ARC) Pin A B C D E F Wiring 77 Remote potentiometer, 5K 76 Remote potentiometer, wiper 75 Remote potentiometer, common Trigger, common Trigger, input Ground CABLE CONNECTIONS See FIGURE A.2 for locating 6-pin and 14-pin con- nectors on the front of the FX450. FIGURE A.2 Function 6-pin remote control con- nector f ...

  • Lincoln Electric RED-D-ARC FX450 - page 13

    A-6 INST ALLA TION FX450 (RED-D-ARC) A-6 RECOMMENDED ELECTRODE AND WORK CABLE SIZES FOR ARC WELDING General Guidelines Connect the electrode and work cables between the appropriate output studs of the FX450 per the follow- ing guidelines: • Most welding applications run with the electrode being positive (+). For those applications, connect the el ...

  • Lincoln Electric RED-D-ARC FX450 - page 14

    B-1 OPERA TION FX450 (RED-D-ARC) B-1 SAFETY PRECAUTIONS Read this entire section of operating instructions before operating the machine. ELECTRIC SHOCK can kill. • Unless using cold feed feature, when feeding with gun trigger, the electrode and drive mechanism are always electrically energized and could remain energized several seconds after the ...

  • Lincoln Electric RED-D-ARC FX450 - page 15

    B-2 OPERA TION B-2 FX450 (RED-D-ARC) PRODUCT DESCRIPTION The FX450 is a multi-process CC/CV DC inverter and is rated for 450 amps, 38 volts at a 60% duty cycle. This machine is intended for both factory and field operation. It comes in a compact, rugged case that is designed for portability and outdoor use with an IP23 environmental rating. The use ...

  • Lincoln Electric RED-D-ARC FX450 - page 16

    B-3 OPERA TION B-3 RECOMMENDED PROCESSES AND EQUIPMENT RECOMMENDED PROCESSES The FX450 is designed for CC-SMAW, CC-GTAW (lift tig), CV-GMAW, CV-FCAW-SS and CV-FCAW-GS welding processes. CAG (arc gouging) is also supported. PROCESS LIMIT A TIONS The FX450 is suitable only for the processes listed. EQUIPMENT LIMIT A TIONS Operating Temperature Range ...

  • Lincoln Electric RED-D-ARC FX450 - page 17

    B-4 OPERA TION B-4 CASE FRONT CONTROL DESCRIPTIONS (See Figure B.1) 1. Power Switch 2. Voltage Display Meter 3. Amperage Display Meter 4. Thermal LED 5. Output Control Dial 6. Weld Process Selector Switch 7. Hot Start Toggle Switch 8. Output Control Local/Remote Toggle Switch 9. Arc Control Dial 10. W e l d Te r m i n a l s On/Remote toggle selecto ...

  • Lincoln Electric RED-D-ARC FX450 - page 18

    B-5 OPERA TION B-5 FX450 (RED-D-ARC) CASE BACK CONTROL (See Figure B.2) 1. Input Power Cord Access Hole. 1 1 FIGURE B.2 COMMON WELDING PROCEDURES MAKING A WELD The serviceability of a product or structure utiliz- ing the welding programs is and must be the sole responsibility of the builder/user. Many variables beyond the control of The Lincoln Ele ...

  • Lincoln Electric RED-D-ARC FX450 - page 19

    B-6 OPERA TION B-6 Amperage Display Meter • Prior to STICK or TIG operation (current flow), the meter displays preset current value. • Prior to CV operation, the meter displays four dash- es indicating non-presettable AMPS. • During welding, this meter displays actual average amps. • After welding, the meter holds the actual current value f ...

  • Lincoln Electric RED-D-ARC FX450 - page 20

    B-7 OPERA TION B-7 GT A W This weld mode is a constant current (CC) mode featuring con- tinuous control from 10 – 500 amps. It is intended for the GTAW TIG welding processes. Hot Start - The Hot Start control regulates the starting current at arc initiation. Hot Start can be set to “Off” and no additional current is added at arc start. When s ...

  • Lincoln Electric RED-D-ARC FX450 - page 21

    B-8 OPERA TION B-8 CV -INNERSHIELD This weld mode is a constant voltage (CV) mode fea- turing continuous control from 10 to 45 volts. It is intended for the FCAW-SS welding process and arc gouging. Hot Start – Toggle to “ON” position to provide more energy during the start of a weld. Arc Control – The Arc Control regulates pinch effect. At ...

  • Lincoln Electric RED-D-ARC FX450 - page 22

    C-1 ACCESSORIES C-1 OPTIONS / ACCESSORIES General Options K2149-1 Work Lead Package. K1842-10 10ft. Weld Power Cable (Lug to Lug). Inverter and Wire Feeder Cart Rear-wheeled cart includes front casters and no-lift gas bottle platform. Convenient handles allow for easy cable storage while full length side trays store parts and tools. Shipped fully a ...

  • Lincoln Electric RED-D-ARC FX450 - page 23

    D-1 MAINTENANCE D-1 PERIODIC MAINTENANCE Thermal Protection Thermostats protect the machine from excessive operating temperatures. Excessive temperatures may be caused by a lack of cooling air or operating the machine beyond the duty cycle and output rating. If excessive operating temperature should occur, the thermostat will disable the machine ...

  • Lincoln Electric RED-D-ARC FX450 - page 24

    E-1 TROUBLESHOOTING E-1 FX450 (RED-D-ARC) If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION This Troubleshooting Guide is provided to help you locate and repair possib ...

  • Lincoln Electric RED-D-ARC FX450 - page 25

    E-2 TROUBLESHOOTING E-2 FX450 (RED-D-ARC) Observe all Safety Guidelines detailed throughout this manual PROBLEMS (SYMPTOMS) POSSIBLE CAUSE RECOMMENDED COURSE OF ACTION Major physical or electrical damage is evident when the sheet metal covers are removed. Machine wonʼt weld, canʼt get any output. Thermal symbol is lit. Wire feeder wonʼt work. Ap ...

  • Lincoln Electric RED-D-ARC FX450 - page 26

    E-3 TROUBLESHOOTING E-3 FX450 (RED-D-ARC) Observe all Safety Guidelines detailed throughout this manual USING THE ST A TUS LED TO TROUBLESHOOT SYSTEM PROBLEMS Errors are displayed on the user interface. In addition, there are status lights on the control pc board and the switch pc board that contain error sequences. Included in this section is info ...

  • Lincoln Electric RED-D-ARC FX450 - page 27

    F-1 DIAGRAMS F-1 FX450 (RED-D-ARC) NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code n ...

  • Lincoln Electric RED-D-ARC FX450 - page 28

    F-2 DIMENSION PRINT F-2 FX450 (RED-D-ARC) L15698 A.01 26.66 18.78 14.14 26.51 13.06 L15698 A.01 26.66 18.78 14.14 26.51 13.06 ...

  • Lincoln Electric RED-D-ARC FX450 - page 29

    W ARNING A VISO DE PREC A UCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERS T AND THE MANUF A CTURER’S INS TRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLL O W Y OUR EMPL O YER’S SAFETY PRA CTICES. SE RECOMIEND A LEER Y ENTENDER LA S INSTR UCCIONES DEL F ABRIC ...

  • Lincoln Electric RED-D-ARC FX450 - page 30

    W ARNING A VISO DE PREC A UCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREEND A A S INSTR UÇÕES DO F ABRIC ANTE P ARA ES TE EQUIP AMENT O E AS P AR TES DE USO , E SIGA AS PRÁTIC A S DE SEGUR ANÇA DO EMPREGADOR. • Keep your head out of fumes. • Use ventilation or exhaust to re ...

  • Lincoln Electric RED-D-ARC FX450 - page 31

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • ...

メーカー Lincoln Electric カテゴリー Welder

Lincoln Electric RED-D-ARC FX450のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- RED-D-ARC FX450の取扱説明書
- Lincoln Electricの製品カード
- パンフレット
- またはLincoln Electric RED-D-ARC FX450の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Lincoln Electric RED-D-ARC FX450の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Lincoln Electric RED-D-ARC FX450の取り付け説明書、サービスマニュアル、簡易説明書、またはLincoln Electric RED-D-ARC FX450のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Lincoln Electric RED-D-ARC FX450の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Lincoln Electric RED-D-ARC FX450デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLincoln Electric RED-D-ARC FX450を使用するのを助ける技術的文書のことです。説明書は通常、全てのLincoln Electric RED-D-ARC FX450ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Lincoln Electricの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Lincoln Electric RED-D-ARC FX450の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLincoln Electric RED-D-ARC FX450の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Lincoln Electric RED-D-ARC FX450に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Lincoln Electric RED-D-ARC FX450デバイスの基本機能を使うにあたってのヒント。 Lincoln Electric RED-D-ARC FX450のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Lincoln Electric RED-D-ARC FX450に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLincoln Electric RED-D-ARC FX450のメーカー/サービスへの連絡先に関する情報。

Lincoln Electric RED-D-ARC FX450についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLincoln Electric RED-D-ARC FX450の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLincoln Electric RED-D-ARC FX450で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)