    #23960 P1ge 1 W ARNING Improper installation, adjustment, alteration, service or maintenance can cause serious injury or pr oper ty damage. Refer to this manual. For assistance or additional inf ormation, consult a qualified installer or ser vice agency . CAUTION The recommended temperature for normal resid ential use is 120°F . The dial on the aq ...

  • Rheem Indirect Water Heater - page 2

    P age 2 T ABLE OF CONTENTS Section I: Specifications ....................................................... 3 Section II: General Informations ................................................. 5 Section III: Pre-Installation ...................................................... 7 Section IV : Installation ......................................... ...

  • Rheem Indirect Water Heater - page 3

    P age 3 G Cold Inlet, 3/4" NPT Ho t Ou tlet / Anode Rod , 3/4" NPT Anode Rod Aquast at T&P Relief Va lv e Fr om Bo iler Supply , 1" NPT To Bo iler Return, 1" NPT Dr ain Va lv e F D C E B A SECTION I: SPECIFICA TIONS Foam insulation standard on indirect water heater models. Pressures, all: T est pressure, 300 PSI Working pres ...

  • Rheem Indirect Water Heater - page 4

    Page 4 SECTION I: SPECIFICA TIONS (cont.) STID30 30 1.38 110 85 25 55,000 1.3 2.0 STID40 38 2.30 153 120 33 77,000 1.1 3.0 STID50 45 2.30 160 120 40 77,000 1.0 3.0 STID80 75 2.76 200 130 70 83,000 0.9 5.0 STID120 110 2.76 232 130 102 83,000 1.2 5.0 Model Actual T ank Volume (gal) Coil Volume (gal) First Hour Rating (gal)* Continuous Draw Rating (GP ...

  • Rheem Indirect Water Heater - page 5

    SECTION II: GENERAL INFORMA TION LOCA TION The indirect water heater should be located in a central location to the piping system, as close as practical to the boiler and in an area not subject to freezing temperatures. Leave sufficient space for servicing and maintaining the indirect water heater . NO TICE: Long heating supply runs can lengthen re ...

  • Rheem Indirect Water Heater - page 6

    Page 6 SECTION II: GENERAL INFORMA TION (cont.) ANODE RODS The anode rod is used as a sacrificial element within the volume of the storage tank. The purpose of the magnesium anode r od is to protect the inside of the tank against corrosion. Anode r ods should be inspected twice in the first year and at least yearly once a time interval for inspecti ...

  • Rheem Indirect Water Heater - page 7

    SECTION III: PRE-INST ALLA TION BOILER AND CIRCULA T OR SIZING The ratings published in this manual for your Rheem indirect water heater can be obtained through proper selection of boiler output and circulator capacity . As noted, the ratings in T able 2 are based on a 77°F rise with 58°F potable water inlet temperature at a circulator pump flow ...

  • Rheem Indirect Water Heater - page 8

    Page 8 UP 15-42F /FR Closed S y stem s , 60 Hz UP 26-64F Closed S y stem s , 60 Hz SECTION III: PRE-INST ALLA TION (cont.) Figure 4: GRUNDFOS UP 15-42F performance curve Figure 5: GRUNDFOS UP 26-64F performance curve NO TICE: Zone valves on the heat source supply to the indirect water heater are not recommended and will drastically reduce perf orma ...

  • Rheem Indirect Water Heater - page 9

    BOILER SYSTEM SUPP L Y CIRCULA TO R PUMP BOILER SYSTEM RETURN BOILER COLD 1" INLET WA TER HE A T ER INDIRECT HO T OUT DOMESTIC 1 1/2" BOILER FROM TO BOILER CHECK V A L V E BOILER SUPP L Y SYSTEM DOMESTIC 3/4" HO T OUT INDIRECT WA TER HE A T ER BOILER TO BOILER FROM COLD INLET 3/4" V A L V E CHECK PUMP CIRCULA TO R RETURN SYSTEM ...

  • Rheem Indirect Water Heater - page 10

    Page 10 See Figure 8 for piping your Rheem indirect water heater to a low-mass boiler (diagram recommended b y boiler manufacturer). SECTION IV : INST ALLA TION (cont.) CHECK VA LV ES ZONE CIRCULA TORS ISOLA TION VA LV ES ADDITIONAL ZONES INDIRECT CIRCUL AT OR INDIRECT WA TER HEA TER TO HE AT ING ZONE AIR SE PA RA TOR AIR VENT EXP ANSION TA NK COLD ...

  • Rheem Indirect Water Heater - page 11

    ELECTRICAL CONNECTIONS Figures 9 and 10 are general wiring diagrams. For a maintaining temperature boiler , Figure 9 should c losely match your system. For cold start boilers your wiring may resemble Figure 10, but will vary depending on the boiler type and controls or rela ys used. It is not possible to list all wiring v ariations here. When conne ...

  • Rheem Indirect Water Heater - page 12

    Page 12 SECTION V : MAINTENANCE W A TER PIPING On an annual basis, all piping should be checked for leakage at joints, shut-off v alves, and unions. T&P RELIEF V AL VE On an annual basis, the temperature and pressure relief valve should be chec ked for proper operation. First, attach a drain line to the valve to direct the water discharge to an ...

  • Rheem Indirect Water Heater - page 13

    &LUFXODWRUGRHVQRW RSHUDWH &KHFNDTXDVWDWVHWWLQJ 352%/( 0& $86( 62/87,21 %RLOHUGRHVQRW RSHUDWH 5HIHUWRERLOHULQVWDOODWLRQ LQVWUXFWLRQV &KHFNPDLQVHUYLFHVZLWFK &KHFNIXVHGGLVFRQQHFW 3HDNXVHRIKRWZDWHU LVJUHDWHUWKDQWDQN VWRUDJHFDSDFLW 'HWHUPLQHSHDN ...

  • Rheem Indirect Water Heater - page 14

    SECTION VII: P ARTS LIST No. Description A pplicab le Models 1 Anode All models. 2 Anode Outlet STID 30, STID 40, STID 50 3 T&P Relief V alve All models. 4 Drain V alve All models. 5 Aquastat All models. Page 14 14 2 1 3 4 5 ...

  • Rheem Indirect Water Heater - page 15

    Page 15 LIMITED W ARRANTY For Rheem/Ruud™ Indirect Water Heaters. GENERAL This Limited Warranty is only available to the original owner of this water heater. It is not transferable. The Rheem Water Heater Operation of Rheem Manufacturing Company (Rheem) warrants this water heater , and its component parts, to be free from defects in materials and ...

  • Rheem Indirect Water Heater - page 16

    Page 16 EXCLUSIVE W ARRANTY – LIMIT A TION OF LIABILITY This Limited Warranty is the only W arranty given by the manufacturer , the Rheem W ater Heater Operation of Rheem Manufacturing Company , for this unit. No one is authorized to make any other warranties on behalf of the manufacturer . ANY IMPLIED W ARRANTIES, INCLUDING MERCHANT ABILITY , OR ...

メーカー Rheem カテゴリー Water Heater

Rheem Indirect Water Heaterのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Indirect Water Heaterの取扱説明書
- Rheemの製品カード
- パンフレット
- またはRheem Indirect Water Heaterの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Rheem Indirect Water Heaterの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Rheem Indirect Water Heaterの取り付け説明書、サービスマニュアル、簡易説明書、またはRheem Indirect Water Heaterのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Rheem Indirect Water Heaterの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Rheem Indirect Water Heaterデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがRheem Indirect Water Heaterを使用するのを助ける技術的文書のことです。説明書は通常、全てのRheem Indirect Water Heaterユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Rheemの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Rheem Indirect Water Heaterの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははRheem Indirect Water Heaterの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Rheem Indirect Water Heaterに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Rheem Indirect Water Heaterデバイスの基本機能を使うにあたってのヒント。 Rheem Indirect Water Heaterのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Rheem Indirect Water Heaterに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるRheem Indirect Water Heaterのメーカー/サービスへの連絡先に関する情報。

Rheem Indirect Water Heaterについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもRheem Indirect Water Heaterの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがRheem Indirect Water Heaterで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)